These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

206 related articles for article (PubMed ID: 25840407)

  • 1. The clinical implications of balloon rupture during cardiovascular interventions.
    Christopoulos G; Luna M; Brilakis ES
    J Invasive Cardiol; 2015 Apr; 27(4):E45-50. PubMed ID: 25840407
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Embolization of hydrophilic coating material to small intracardial arteries after multiple percutaneous transluminal angioplasty procedures.
    Schipper ME; Stella PR; de Jonge N; Virmani R; de Weger RA; Vink A
    Int J Cardiol; 2012 Mar; 155(3):e45-6. PubMed ID: 21851997
    [No Abstract]   [Full Text] [Related]  

  • 3. Aspirating and filtering atherothrombotic debris during percutaneous coronary intervention.
    Bates ER
    JACC Cardiovasc Interv; 2008 Jun; 1(3):265-7. PubMed ID: 19463310
    [No Abstract]   [Full Text] [Related]  

  • 4. Coronary perforation and tamponade during thrombectomy and treatment with PTFE coated stent and autotransfusion: a case report.
    Bilge AK; Nişanci Y; Ozben B; Yilmaz E; Umman B
    Anadolu Kardiyol Derg; 2003 Jun; 3(2):174-6. PubMed ID: 12826515
    [No Abstract]   [Full Text] [Related]  

  • 5. Air embolism caused by balloon rupture resolved by manual thrombectomy catheter aspiration.
    Rigatelli G; Dell'Avvocata F; Giordan M; Cardaioli P
    Cardiovasc Revasc Med; 2011; 12(2):129-30. PubMed ID: 21421192
    [No Abstract]   [Full Text] [Related]  

  • 6. Intracoronary fracture and embolization of a coronary angioplasty balloon catheter: retrieval by a simple technique.
    Kuchulakanti P
    Catheter Cardiovasc Interv; 2003 Nov; 60(3):425. PubMed ID: 14571501
    [No Abstract]   [Full Text] [Related]  

  • 7. Coronary artery dissection by an oversized balloon.
    Yafi W; Jacquemin L
    BMJ Case Rep; 2014 Dec; 2014():. PubMed ID: 25479753
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Coronary embolization following balloon dilation of lipid-core plaques.
    Goldstein JA; Grines C; Fischell T; Virmani R; Rizik D; Muller J; Dixon SR
    JACC Cardiovasc Imaging; 2009 Dec; 2(12):1420-4. PubMed ID: 20083078
    [No Abstract]   [Full Text] [Related]  

  • 9. Percutaneous transcatheter retrieval of retained balloon catheter in distal tortuous coronary artery: a modified double-helix approach.
    Hung CL; Tsai CT; Hou CJ
    Catheter Cardiovasc Interv; 2004 Aug; 62(4):471-5. PubMed ID: 15274156
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Intracoronary fracture and embolization of a coronary angioplasty balloon catheter: retrieval by a simple technique.
    Trehan V; Mukhopadhyay S; Yusuf J; C Ramgasetty U; Mukherjee S; Arora R
    Catheter Cardiovasc Interv; 2003 Apr; 58(4):473-7. PubMed ID: 12652497
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Catastrophic coronary stent fracture and coronary perforation presenting as cardiogenic shock: a rare but fatal late complication of stenting.
    Choi JH; Song BG; Song YB; Hahn JY; Choi SH; Kim WS; Gwon HC; Lee SH
    Circ Cardiovasc Imaging; 2008 Jul; 1(1):e7-8. PubMed ID: 19808506
    [No Abstract]   [Full Text] [Related]  

  • 12. Intracoronary thrombin injection using a microcatheter to treat guidewire-induced coronary artery perforation.
    Fischell TA; Moualla SK; Mannem SR
    Cardiovasc Revasc Med; 2011; 12(5):329-33. PubMed ID: 21367674
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [A rare case of coronary artery perforation by a PTCA guide wire complicating with postinfarction cardiac rupture after thrombolytic therapy].
    Ogino H; Miki S; Ueda Y; Tahata T; Morioka K; Sakai T
    Nihon Kyobu Geka Gakkai Zasshi; 1995 Aug; 43(8):1151-4. PubMed ID: 7594850
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Successful closure of coronary artery perforation using non-conventional embolic material.
    Trehan VK; Mulkhopadhyay S; Yusuf J; Rangasetty UC; Arora R
    Indian Heart J; 2005; 57(2):170-1. PubMed ID: 16013360
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Distal protection beneficial?
    van der Wall EE; Bax JJ; Jukema JW; Schalij MJ
    Int J Cardiovasc Imaging; 2010 Feb; 26(2):135-8. PubMed ID: 20175293
    [No Abstract]   [Full Text] [Related]  

  • 16. Balloon rupture complication.
    Mascarenhas DA; Sapería GM; Benotti JR
    Cathet Cardiovasc Diagn; 1993 Nov; 30(3):266-8. PubMed ID: 8269503
    [No Abstract]   [Full Text] [Related]  

  • 17. Spontaneous and catheter-induced secondary coronary artery dissection: a single-centre experience.
    Bulum J; Strozzi M; Smalcelj A
    Acta Cardiol; 2008 Apr; 63(2):203-6. PubMed ID: 18468201
    [TBL] [Abstract][Full Text] [Related]  

  • 18. [Guide-wire rupture as a complication of coronary angioplasty. Apropos 2 cases and a review of the literature].
    Ojeda Delgado JL; Jiménez Mena M; Barrios Alonso V; Pena Tizón J; Fernández Sánchez-Villarán E; Hernández Madrid A; Marín Huerta E; Pey Illera J
    Rev Esp Cardiol; 1992 Feb; 45(2):141-4. PubMed ID: 1561468
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prevention and treatment of microvascular obstruction-related myocardial injury and coronary no-reflow following percutaneous coronary intervention: a systematic approach.
    Jaffe R; Dick A; Strauss BH
    JACC Cardiovasc Interv; 2010 Jul; 3(7):695-704. PubMed ID: 20650430
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Management of a distal coronary psudoaneurysm using an amplatzer vascular plug II.
    Lindefjeld DS; Gómez-Menchero A; Díaz JF
    Cardiovasc Revasc Med; 2014 Jan; 15(1):54-7. PubMed ID: 23954082
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 11.