BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

232 related articles for article (PubMed ID: 25840479)

  • 1. Two versus 3 lag screws for fixation of long oblique proximal phalanx fractures of the fingers: a cadaver study.
    Zelken JA; Hayes AG; Parks BG; Al Muhit A; Means KR
    J Hand Surg Am; 2015 Jun; 40(6):1124-9. PubMed ID: 25840479
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Lag Versus Nonlag Screw Fixation for Long Oblique Proximal Phalanx Fractures: A Biomechanical Study.
    Miles MR; Green T; Parks BG; Thakkar MY; Segalman KA; Means KR
    J Hand Surg Am; 2022 May; 47(5):476.e1-476.e6. PubMed ID: 34247847
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Minimally Invasive Intramedullary Screw Versus Plate Fixation for Proximal Phalanx Fractures: A Biomechanical Study.
    Miles MR; Krul KP; Abbasi P; Thakkar MY; Giladi AM; Means KR
    J Hand Surg Am; 2021 Jun; 46(6):518.e1-518.e8. PubMed ID: 33423850
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Lag screw fixation of medial malleolar fractures: a biomechanical, radiographic, and clinical comparison of unicortical partially threaded lag screws and bicortical fully threaded lag screws.
    Ricci WM; Tornetta P; Borrelli J
    J Orthop Trauma; 2012 Oct; 26(10):602-6. PubMed ID: 22437423
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Stability of fixation of proximal phalanx unicondylar fractures of the hand: a biomechanical cadaver study.
    Sirota MA; Parks BG; Higgins JP; Means KR
    J Hand Surg Am; 2013 Jan; 38(1):77-81. PubMed ID: 23200947
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy in Screw Selection in a Cadaveric, Small-Bone Fracture Model.
    Jernigan EW; Honeycutt PB; Patterson JMM; Rummings WA; Bynum DK; Draeger RW
    J Hand Surg Am; 2018 Dec; 43(12):1138.e1-1138.e8. PubMed ID: 29801935
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volar Anatomy of the Proximal Phalanx: Implications for Screw Length Selection for Fixation of Shaft Fractures.
    Honeycutt PB; Jernigan EW; Rummings WA; Stern PJ; Draeger RW
    J Hand Surg Am; 2017 Mar; 42(3):e149-e157. PubMed ID: 28259279
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Biomechanical Evaluation of Plate Versus Lag Screw Only Fixation of Distal Fibula Fractures.
    Misaghi A; Doan J; Bastrom T; Pennock AT
    J Foot Ankle Surg; 2015; 54(5):896-9. PubMed ID: 25990534
    [TBL] [Abstract][Full Text] [Related]  

  • 9. [Open reduction and low-profile plate and/or screw fixation in the treatment of phalangeal fractures].
    Nalbantoğlu U; Gereli A; Cilli F; Uçar BY; Türkmen M
    Acta Orthop Traumatol Turc; 2009; 43(4):317-23. PubMed ID: 19809228
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Screw fixation of scaphoid fractures: a biomechanical assessment of screw length and screw augmentation.
    Dodds SD; Panjabi MM; Slade JF
    J Hand Surg Am; 2006 Mar; 31(3):405-13. PubMed ID: 16516734
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Headless Compression Screw Fixation for Proximal Phalanx Fractures: A Biomechanical Study.
    Fader L; Robinson L; Voor M
    Hand (N Y); 2022 Mar; 17(2):239-244. PubMed ID: 32452267
    [No Abstract]   [Full Text] [Related]  

  • 12. Angular stable lateral plating is a valid alternative to conventional plate fixation in the proximal phalanx. A biomechanical study.
    Shanmugam R; Ernst M; Stoffel K; Fischer MF; Wahl D; Richards RG; Gueorguiev B
    Clin Biomech (Bristol, Avon); 2015 Jun; 30(5):405-10. PubMed ID: 25846324
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Treatment of proximal phalangeal fractures with an antegrade intramedullary screw: a cadaver study.
    Borbas P; Dreu M; Poggetti A; Calcagni M; Giesen T
    J Hand Surg Eur Vol; 2016 Sep; 41(7):683-7. PubMed ID: 27056278
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The Greco-Nice-Lag: Lag Screw and Double Nice Knot Fixation for Spiral Proximal Phalanx Fractures-Connecting the Shoulder to the Finger.
    Greco VE; Wiesler E
    Tech Hand Up Extrem Surg; 2024 Jun; 28(2):110-114. PubMed ID: 37991095
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Biomechanical cadaver testing of a fixed-angle plate in comparison to tension wiring and screw fixation in transverse patella fractures.
    Thelen S; Schneppendahl J; Jopen E; Eichler C; Koebke J; Schönau E; Hakimi M; Windolf J; Wild M
    Injury; 2012 Aug; 43(8):1290-5. PubMed ID: 22608600
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Trans-metacarpal Screw Fixation for Extra-articular Proximal Phalangeal Base Fractures.
    Itadera E; Yamazaki T
    J Hand Surg Asian Pac Vol; 2017 Mar; 22(1):35-38. PubMed ID: 28205482
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Osteosynthesis of Phalangeal Fractures: Biomechanical Comparison of Kirschner Wires, Plates, and Compression Screws.
    Rausch V; Harbrecht A; Kahmann SL; Fenten T; Jovanovic N; Hackl M; Müller LP; Staat M; Wegmann K
    J Hand Surg Am; 2020 Oct; 45(10):987.e1-987.e8. PubMed ID: 32499069
    [TBL] [Abstract][Full Text] [Related]  

  • 18. A randomized comparison of bone-cement K-wire fixation vs. plate fixation of shaft fractures of proximal phalanges.
    Zhang X; Yu Y; Shao X; Dhawan V; Du W
    Phys Sportsmed; 2019 May; 47(2):189-198. PubMed ID: 30408421
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optimal fixation of oblique scaphoid fractures: a cadaver model.
    Luria S; Lenart L; Lenart B; Peleg E; Kastelec M
    J Hand Surg Am; 2012 Jul; 37(7):1400-4. PubMed ID: 22633229
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Kirschner Wires Versus Titanium Plates and Screws in Management of Unstable Phalangeal Fractures: A Randomized, Controlled Clinical Trial.
    El-Saeed M; Sallam A; Radwan M; Metwally A
    J Hand Surg Am; 2019 Dec; 44(12):1091.e1-1091.e9. PubMed ID: 30803743
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 12.