BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

139 related articles for article (PubMed ID: 25855757)

  • 1. Screening urine samples for the absence of urinary tract infection using the sediMAX automated microscopy analyser.
    Sterry-Blunt RE; S Randall K; J Doughton M; H Aliyu S; A Enoch D
    J Med Microbiol; 2015 Jun; 64(6):605-609. PubMed ID: 25855757
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Screening of presumptive urinary tract infections by the automated urine sediment analyser sediMAX.
    Tessari A; Osti N; Scarin M
    Clin Chem Lab Med; 2015 Nov; 53 Suppl 2():s1503-8. PubMed ID: 26509783
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Rapid Screening of Urinary Tract Infection and Discrimination of Gram-Positive and Gram-Negative Bacteria by Automated Flow Cytometric Analysis Using Sysmex UF-5000.
    Kim SY; Park Y; Kim H; Kim J; Koo SH; Kwon GC
    J Clin Microbiol; 2018 Aug; 56(8):. PubMed ID: 29769277
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Analytic performance of bacteriuria and leukocyturia obtained by UriSed in culture positive urinary tract infections.
    Karakukcu C; Kayman T; Ozturk A; Torun YA
    Clin Lab; 2012; 58(1-2):107-11. PubMed ID: 22372352
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Evaluation of BacterioScan 216Dx in Comparison to Urinalysis as a Screening Tool for Diagnosis of Urinary Tract Infections in Children.
    Hassan F; Bushnell H; Taggart C; Gibbs C; Hiraki S; Formanek A; Gripka M; Selvarangan R
    J Clin Microbiol; 2019 Sep; 57(9):. PubMed ID: 31217269
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of the SediMax automated microscopy sediment analyzer and the Sysmex UF-1000i flow cytometer as screening tools to rule out negative urinary tract infections.
    Íñigo M; Coello A; Fernández-Rivas G; Carrasco M; Marcó C; Fernández A; Casamajor T; Ausina V
    Clin Chim Acta; 2016 May; 456():31-35. PubMed ID: 26921459
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Performance of the cobas u 701 Analyzer in Urinary Tract Infection Screening.
    Ortiz de la Tabla V; Gázquez G; Infante A; Martin C; Buñuel F; Gutiérrez F
    Ann Lab Med; 2019 Sep; 39(5):464-469. PubMed ID: 31037865
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Can routine automated urinalysis reduce culture requests?
    Kayalp D; Dogan K; Ceylan G; Senes M; Yucel D
    Clin Biochem; 2013 Sep; 46(13-14):1285-9. PubMed ID: 23810583
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Use of flow cytometry (Sysmex) UF-100) to screen for positive urine cultures: in search for the ideal cut-off.
    Brilha S; Proença H; Cristino JM; Hänscheid T
    Clin Chem Lab Med; 2010 Feb; 48(2):289-92. PubMed ID: 19961394
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic Accuracy of a New Urinalysis System, DongJiu, for Diagnosis of Urinary Tract Infection.
    Kocer D; Sariguzel FM; Ciraci MZ; Karakukcu C; Oz L
    Ann Clin Lab Sci; 2015; 45(6):686-91. PubMed ID: 26663800
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Analysis of the costs for the laboratory of flow cytometry screening of urine samples before culture.
    Paattiniemi EL; Karumaa S; Viita AM; Kärpänoja P; Mäkelä M; Isojärvi J; Sarkkinen H
    Infect Dis (Lond); 2017 Mar; 49(3):217-222. PubMed ID: 27766919
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cost-effectiveness of a new system in ruling out negative urine cultures on the day of administration.
    Ilki A; Ayas R; Ozsoy S; Soyletir G
    Eur J Clin Microbiol Infect Dis; 2017 Jul; 36(7):1119-1123. PubMed ID: 28111725
    [TBL] [Abstract][Full Text] [Related]  

  • 13. [Evaluation of the Sysmex UF-1000i automated system for the diagnosis of urinary tract infection].
    Muñoz-Algarra M; Martínez-Ruiz R; Orden-Martínez B
    Enferm Infecc Microbiol Clin; 2013 Jan; 31(1):29-31. PubMed ID: 22858173
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of the new Sysmex UF-5000 fluorescence flow cytometry analyser for ruling out bacterial urinary tract infection and for prediction of Gram negative bacteria in urine cultures.
    De Rosa R; Grosso S; Lorenzi G; Bruschetta G; Camporese A
    Clin Chim Acta; 2018 Sep; 484():171-178. PubMed ID: 29803898
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Clinical usefulness of iQ200/iChem Velocity workstation for screening of urine culture.
    Lee JM; Baek DJ; Park KG; Han E; Park YJ
    BMC Infect Dis; 2019 Jun; 19(1):531. PubMed ID: 31208347
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Should we abandon standard microscopy when screening for urinary tract infections in young children?
    Armengol CE; Hendley JO; Schlager TA
    Pediatr Infect Dis J; 2001 Dec; 20(12):1176-7. PubMed ID: 11740329
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Evaluation of the Sysmex UF1000i flow cytometer for ruling out bacterial urinary tract infection.
    De Rosa R; Grosso S; Bruschetta G; Avolio M; Stano P; Modolo ML; Camporese A
    Clin Chim Acta; 2010 Aug; 411(15-16):1137-42. PubMed ID: 20359474
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Direct Identification of Urinary Tract Pathogens from Urine Samples, Combining Urine Screening Methods and Matrix-Assisted Laser Desorption Ionization-Time of Flight Mass Spectrometry.
    Íñigo M; Coello A; Fernández-Rivas G; Rivaya B; Hidalgo J; Quesada MD; Ausina V
    J Clin Microbiol; 2016 Apr; 54(4):988-93. PubMed ID: 26818668
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Improvement in the detection of enteric protozoa from clinical stool samples using the automated urine sediment analyzer sediMAX
    Intra J; Sala MR; Falbo R; Cappellini F; Brambilla P
    Eur J Clin Microbiol Infect Dis; 2017 Jan; 36(1):147-151. PubMed ID: 27646557
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy of Automated Flow Cytometry-Based Leukocyte Counts To Rule Out Urinary Tract Infection in Febrile Children: a Prospective Cross-Sectional Study.
    Duong HP; Wissing KM; Tram N; Mascart G; Lepage P; Ismaili K
    J Clin Microbiol; 2016 Dec; 54(12):2975-2981. PubMed ID: 27682127
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.