139 related articles for article (PubMed ID: 25855757)
21. Cutoff values for bacteria and leukocytes for urine sediment analyzer FUS200 in culture-positive urinary-tract infections.
Kocer D; Sarıguzel FM; Karakukcu C
Scand J Clin Lab Invest; 2014 Aug; 74(5):414-7. PubMed ID: 24693995
[TBL] [Abstract][Full Text] [Related]
22. Interlaboratory Collaboration for Optimized Screening for Urinary Tract Infection.
Russcher A; Kusters E; Wolterbeek R; Kuijper EJ; Cobbaert CM; van der Beek MT
J Clin Microbiol; 2016 Jan; 54(1):93-8. PubMed ID: 26491183
[TBL] [Abstract][Full Text] [Related]
23. Predicting urine culture results by dipstick testing and phase contrast microscopy.
Smith P; Morris A; Reller LB
Pathology; 2003 Apr; 35(2):161-5. PubMed ID: 12745465
[TBL] [Abstract][Full Text] [Related]
24. A comparison of chemical dipsticks read visually or by photometry in the routine screening of urine specimens in the clinical microbiology laboratory.
Holland DJ; Bliss KJ; Allen CD; Gilbert GL
Pathology; 1995 Jan; 27(1):91-6. PubMed ID: 7603764
[TBL] [Abstract][Full Text] [Related]
25. [Comparison of IRIS IQ ELITE and microscopy for urinalysis and evaluation of performance in predicting outcome of urine cultures].
Ledru S; Canonne JP
Ann Biol Clin (Paris); 2008; 66(5):555-9. PubMed ID: 18957345
[TBL] [Abstract][Full Text] [Related]
26. Performance of Copan WASP for Routine Urine Microbiology.
Quiblier C; Jetter M; Rominski M; Mouttet F; Böttger EC; Keller PM; Hombach M
J Clin Microbiol; 2016 Mar; 54(3):585-92. PubMed ID: 26677255
[TBL] [Abstract][Full Text] [Related]
27. Sysmex UF-1000i flow cytometer to screen urinary tract infections: the URISCAM multicentre study.
Herráez O; Asencio MA; Carranza R; Jarabo MM; Huertas M; Redondo O; Arias-Arias A; Jiménez-Álvarez S; Solís S; Zamarrón P; Illescas MS; Galán MA
Lett Appl Microbiol; 2018 Mar; 66(3):175-181. PubMed ID: 29223137
[TBL] [Abstract][Full Text] [Related]
28. Comparison of a urine chemistry analyser and microscopy, culture and sensitivity results to detect the presence of urinary tract infections in an elective orthopaedic population.
Clement S; Young J; Munday E
Contemp Nurse; 2004; 17(1-2):89-94. PubMed ID: 17929739
[TBL] [Abstract][Full Text] [Related]
29. Screening of urine samples by flow cytometry reduces the need for culture.
Jolkkonen S; Paattiniemi EL; Kärpänoja P; Sarkkinen H
J Clin Microbiol; 2010 Sep; 48(9):3117-21. PubMed ID: 20592157
[TBL] [Abstract][Full Text] [Related]
30. Urinary Squamous Epithelial Cells Do Not Accurately Predict Urine Culture Contamination, but May Predict Urinalysis Performance in Predicting Bacteriuria.
Mohr NM; Harland KK; Crabb V; Mutnick R; Baumgartner D; Spinosi S; Haarstad M; Ahmed A; Schweizer M; Faine B
Acad Emerg Med; 2016 Mar; 23(3):323-30. PubMed ID: 26782662
[TBL] [Abstract][Full Text] [Related]
31. Urine flow cytometry is an adequate screening tool for urinary tract infections in children.
Broeren M; Nowacki R; Halbertsma F; Arents N; Zegers S
Eur J Pediatr; 2019 Mar; 178(3):363-368. PubMed ID: 30569406
[TBL] [Abstract][Full Text] [Related]
32. Performance of urinalysis tests and their ability in predicting results of urine cultures: a comparison between automated test strip analyser and flow cytometry in various subpopulations and types of samples.
Yusuf E; Van Herendael B; van Schaeren J
J Clin Pathol; 2017 Jul; 70(7):631-636. PubMed ID: 27980053
[TBL] [Abstract][Full Text] [Related]
33. Relationship between conventional culture and flow cytometry for the diagnosis of urinary tract infection.
García-Coca M; Gadea I; Esteban J
J Microbiol Methods; 2017 Jun; 137():14-18. PubMed ID: 28330780
[TBL] [Abstract][Full Text] [Related]
34. An Evaluation of the Automated Cobas u 701 Microscopy Analyzer for the Routine Screening of Urine to Identify Negative Samples.
Waterhouse N; Nichol G; Kasapic D
Clin Lab; 2019 Jan; 65(1):. PubMed ID: 30775889
[TBL] [Abstract][Full Text] [Related]
35. Detection of significant bacteriuria by use of the iQ200 automated urine microscope.
Stürenburg E; Kramer J; Schön G; Cachovan G; Sobottka I
J Clin Microbiol; 2014 Aug; 52(8):2855-60. PubMed ID: 24871218
[TBL] [Abstract][Full Text] [Related]
36. Benefits of the iQ200 automated urine microscopy analyser in routine urinalysis.
van den Broek D; Keularts IM; Wielders JP; Kraaijenhagen RJ
Clin Chem Lab Med; 2008; 46(11):1635-40. PubMed ID: 19012529
[TBL] [Abstract][Full Text] [Related]
37. Evaluation of a new rapid urine screening analyser: CellFacts.
Gentelet H; Carricajo A; Rusch P; Dow C; Aubert G
Pathol Biol (Paris); 2001 Apr; 49(3):262-4. PubMed ID: 11367562
[TBL] [Abstract][Full Text] [Related]
38. Screening for urinary tract infection with the Sysmex UF-1000i urine flow cytometer.
Broeren MA; Bahçeci S; Vader HL; Arents NL
J Clin Microbiol; 2011 Mar; 49(3):1025-9. PubMed ID: 21248088
[TBL] [Abstract][Full Text] [Related]
39. Use of nitrite dipstick test in the screening for urinary tract infection in children.
Wammanda RD; Aikhionbare HA; Ogala WN
West Afr J Med; 2000; 19(3):206-8. PubMed ID: 11126085
[TBL] [Abstract][Full Text] [Related]
40. Automated urinalysis and urine dipstick in the emergency evaluation of young febrile children.
Kanegaye JT; Jacob JM; Malicki D
Pediatrics; 2014 Sep; 134(3):523-9. PubMed ID: 25136043
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]