151 related articles for article (PubMed ID: 25857616)
1. Electropolymerized phenol derivatives as permselective polymers for biosensor applications.
Calia G; Monti P; Marceddu S; Dettori MA; Fabbri D; Jaoua S; O'Neill RD; Serra PA; Delogu G; Migheli Q
Analyst; 2015 May; 140(10):3607-15. PubMed ID: 25857616
[TBL] [Abstract][Full Text] [Related]
2. Low electro-synthesis potentials improve permselectivity of polymerized natural phenols in biosensor applications.
Monti P; Calia G; Marceddu S; Dettori MA; Fabbri D; Jaoua S; O'Neill RD; Migheli Q; Delogu G; Serra PA
Talanta; 2017 Jan; 162():151-158. PubMed ID: 27837811
[TBL] [Abstract][Full Text] [Related]
3. Use of β-cyclodextrin as enhancer of ascorbic acid rejection in permselective films for amperometric biosensor applications.
Monti P; Rocchitta G; Marceddu S; Dettori MA; Fabbri D; Jaoua S; Migheli Q; Delogu G; Serra PA
Talanta; 2018 Aug; 186():53-59. PubMed ID: 29784398
[TBL] [Abstract][Full Text] [Related]
4. Contributions by a novel edge effect to the permselectivity of an electrosynthesized polymer for microbiosensor applications.
Rothwell SA; Kinsella ME; Zain ZM; Serra PA; Rocchitta G; Lowry JP; O'Neill RD
Anal Chem; 2009 May; 81(10):3911-8. PubMed ID: 19371060
[TBL] [Abstract][Full Text] [Related]
5. Pt based enzyme electrode probes assembled with Prussian Blue and conducting polymer nanostructures.
Curulli A; Valentini F; Orlanduci S; Terranova ML; Palleschi G
Biosens Bioelectron; 2004 Dec; 20(6):1223-32. PubMed ID: 15556371
[TBL] [Abstract][Full Text] [Related]
6. Amperometric glucose sensor based on coimmobilization of glucose oxidase and Poly(p-phenylenediamine) at a platinum microdisk electrode.
Jing-Juan X; Hong-Yuan C
Anal Biochem; 2000 May; 280(2):221-6. PubMed ID: 10790304
[TBL] [Abstract][Full Text] [Related]
7. Effects of applied potential on the mass of non-conducting poly(ortho-phenylenediamine) electro-deposited on EQCM electrodes: comparison with biosensor selectivity parameters.
Rothwell SA; O'Neill RD
Phys Chem Chem Phys; 2011 Mar; 13(12):5413-21. PubMed ID: 21359356
[TBL] [Abstract][Full Text] [Related]
8. Chemical polymerization of m-phenylenediamine, in the presence of glucose oxidase, produces an enzyme-retaining electrooxidisable polymer used to produce a biosensor for amperometric detection of glucose from brain dialysate.
Osborne PG; Hashimoto M
Analyst; 2004 Aug; 129(8):759-65. PubMed ID: 15284922
[TBL] [Abstract][Full Text] [Related]
9. Glucose biosensor based on immobilization of glucose oxidase in poly(o-aminophenol) film on polypyrrole-Pt nanocomposite modified glassy carbon electrode.
Li J; Lin X
Biosens Bioelectron; 2007 Jun; 22(12):2898-905. PubMed ID: 17215117
[TBL] [Abstract][Full Text] [Related]
10. Permselective and enzyme-entrapping behaviours of an electropolymerized, non-conducting, poly(o-aminophenol) thin film-modified electrode: a critical study.
Guerrieri A; Ciriello R; Centonze D
Biosens Bioelectron; 2009 Feb; 24(6):1550-6. PubMed ID: 19022646
[TBL] [Abstract][Full Text] [Related]
11. Amperometric glucose biosensor based on electroconductive hydrogels.
Kotanen CN; Tlili C; Guiseppi-Elie A
Talanta; 2013 Jan; 103():228-35. PubMed ID: 23200382
[TBL] [Abstract][Full Text] [Related]
12. Protein and polysaccharide-composite sol-gel silicate film for an interference-free amperometric glucose biosensor.
Matsuhisa H; Tsuchiya M; Hasebe Y
Colloids Surf B Biointerfaces; 2013 Nov; 111():523-9. PubMed ID: 23886787
[TBL] [Abstract][Full Text] [Related]
13. Nitric oxide permselectivity in electropolymerized films for sensing applications.
Brown MD; Schoenfisch MH
ACS Sens; 2016 Dec; 1(12):1453-1461. PubMed ID: 31875180
[TBL] [Abstract][Full Text] [Related]
14. Electrocatalytical properties of polymethylferrocenyl dendrimers and their applications in biosensing.
Armada MP; Losada J; Zamora M; Alonso B; Cuadrado I; Casado CM
Bioelectrochemistry; 2006 Sep; 69(1):65-73. PubMed ID: 16443400
[TBL] [Abstract][Full Text] [Related]
15. Sustainable Electropolymerization of Zingerone and Its C2 Symmetric Dimer for Amperometric Biosensor Films.
Caval M; Dettori MA; Carta P; Dallocchio R; Dessì A; Marceddu S; Serra PA; Fabbri D; Rocchitta G
Molecules; 2023 Aug; 28(16):. PubMed ID: 37630267
[TBL] [Abstract][Full Text] [Related]
16. Ferrocene-conjugated m-phenylenediamine conducting polymer-incorporated peroxidase biosensors.
Mulchandani A; Pan S
Anal Biochem; 1999 Feb; 267(1):141-7. PubMed ID: 9918666
[TBL] [Abstract][Full Text] [Related]
17. Development of miniaturized pH biosensors based on electrosynthesized polymer films.
Segut O; Lakard B; Herlem G; Rauch JY; Jeannot JC; Robert L; Fahys B
Anal Chim Acta; 2007 Aug; 597(2):313-21. PubMed ID: 17683745
[TBL] [Abstract][Full Text] [Related]
18. Enzyme immobilization strategies and electropolymerization conditions to control sensitivity and selectivity parameters of a polymer-enzyme composite glucose biosensor.
Rothwell SA; Killoran SJ; O'Neill RD
Sensors (Basel); 2010; 10(7):6439-62. PubMed ID: 22163559
[TBL] [Abstract][Full Text] [Related]
19. A mediator-free amperometric hydrogen peroxide biosensor based on HRP immobilized on a nano-Au/poly 2,6-pyridinediamine-coated electrode.
Cao S; Yuan R; Chai Y; Zhang L; Li X; Gao F
Bioprocess Biosyst Eng; 2007 Mar; 30(2):71-8. PubMed ID: 17242931
[TBL] [Abstract][Full Text] [Related]
20. Electrochemically mediated electrodeposition/electropolymerization to yield a glucose microbiosensor with improved characteristics.
Chen X; Matsumoto N; Hu Y; Wilson GS
Anal Chem; 2002 Jan; 74(2):368-72. PubMed ID: 11811410
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]