These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

566 related articles for article (PubMed ID: 25860265)

  • 1. [Positron emission tomography/computed tomography for lung cancer staging].
    Ladrón de Guevara H D; Furnaro L F; Yévenes A S; Clavero R JM; Lazo P D; Rodríguez D P; Piottante B A; Pefaur D R; Pardo B C
    Rev Med Chil; 2015 Jan; 143(1):22-9. PubMed ID: 25860265
    [TBL] [Abstract][Full Text] [Related]  

  • 2. [Prognostic value of PET/CT in lung cancer: retrospective analysis of 47 patients].
    de Guevara DL; Fuentes A; Fariña C; Corral C; Pefaur R
    Rev Med Chil; 2013 Jan; 141(1):41-8. PubMed ID: 23732413
    [TBL] [Abstract][Full Text] [Related]  

  • 3. False-negative rate after positron emission tomography/computer tomography scan for mediastinal staging in cI stage non-small-cell lung cancer.
    Gómez-Caro A; Boada M; Cabañas M; Sanchez M; Arguis P; Lomeña F; Ramirez J; Molins L
    Eur J Cardiothorac Surg; 2012 Jul; 42(1):93-100; discussion 100. PubMed ID: 22290911
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The role of extended cervical mediastinoscopy in staging of non-small cell lung cancer of the left lung and a comparison with integrated positron emission tomography and computed tomography: does integrated positron emission tomography and computed tomography reduce the need for invasive procedures?
    Metin M; Citak N; Sayar A; Pekcolaklar A; Melek H; Kök A; Gurses A
    J Thorac Oncol; 2011 Oct; 6(10):1713-9. PubMed ID: 21716145
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Positron emission tomography-computed tomography compared with invasive mediastinal staging in non-small cell lung cancer: results of mediastinal staging in the early lung positron emission tomography trial.
    Darling GE; Maziak DE; Inculet RI; Gulenchyn KY; Driedger AA; Ung YC; Gu CS; Kuruvilla MS; Cline KJ; Julian JA; Evans WK; Levine MN
    J Thorac Oncol; 2011 Aug; 6(8):1367-72. PubMed ID: 21587082
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Standardized Uptake Values in the Primary Lesions of Non-Small-Cell Lung Cancer in FDG-PET/CT Can Predict Regional Lymph Node Metastases.
    Nakamura H; Saji H; Marushima H; Kimura H; Tagaya R; Kurimoto N; Hoshikawa M; Takagi M
    Ann Surg Oncol; 2015 Dec; 22 Suppl 3():S1388-93. PubMed ID: 25900205
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The role of (18)F-FDG PET/CT for evaluation of metastatic mediastinal lymph nodes in patients with lung squamous-cell carcinoma or adenocarcinoma.
    Lu P; Sun Y; Sun Y; Yu L
    Lung Cancer; 2014 Jul; 85(1):53-8. PubMed ID: 24792334
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Evaluation of the factors affecting the maximum standardized uptake value of metastatic lymph nodes in different histological types of non-small cell lung cancer on PET-CT.
    Wang Y; Ma S; Dong M; Yao Y; Liu K; Zhou J
    BMC Pulm Med; 2015 Mar; 15():20. PubMed ID: 25880540
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Impact of Pretreatment Combined (18)F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography Staging on Radiation Therapy Treatment Decisions in Locally Advanced Breast Cancer.
    Ng SP; David S; Alamgeer M; Ganju V
    Int J Radiat Oncol Biol Phys; 2015 Sep; 93(1):111-7. PubMed ID: 26279029
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Diagnostic accuracy of 18F-2-deoxy-fluoro-D-glucose positron emission tomography for pN1 lymph nodes in patients with lung cancer.
    Nakagawa M; Hara M; Sakurai K; Ozawa Y; Mizuno A; Tamaki T; Nishio M; Shibamoto Y
    Acta Radiol; 2009 Jul; 50(6):638-44. PubMed ID: 19492198
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Evaluation of integrated positron emission tomography and computed tomography accuracy in detecting lymph node metastasis in patients with adenocarcinoma vs squamous cell carcinoma.
    Billè A; Okiror L; Skanjeti A; Errico L; Arena V; Penna D; Ardissone F; Pelosi E
    Eur J Cardiothorac Surg; 2013 Mar; 43(3):574-9. PubMed ID: 22689182
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of (11)C-choline PET/CT and enhanced CT in the evaluation of patients with pulmonary abnormalities and locoregional lymph node involvement in lung cancer.
    Peng Z; Liu Q; Li M; Han M; Yao S; Liu Q
    Clin Lung Cancer; 2012 Jul; 13(4):312-20. PubMed ID: 22182444
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Preoperative intrathoracic lymph node staging in patients with non-small-cell lung cancer: accuracy of integrated positron emission tomography and computed tomography.
    Billé A; Pelosi E; Skanjeti A; Arena V; Errico L; Borasio P; Mancini M; Ardissone F
    Eur J Cardiothorac Surg; 2009 Sep; 36(3):440-5. PubMed ID: 19464906
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy of positron emission tomography in mediastinal node assessment in coal workers with lung cancer.
    Saydam O; Gokce M; Kilicgun A; Tanriverdi O
    Med Oncol; 2012 Jun; 29(2):589-94. PubMed ID: 21380783
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Value of F-18-fluorodeoxyglucose positron emission tomography after induction therapy of locally advanced bronchogenic carcinoma.
    Hellwig D; Graeter TP; Ukena D; Georg T; Kirsch CM; Schäfers HJ
    J Thorac Cardiovasc Surg; 2004 Dec; 128(6):892-9. PubMed ID: 15573074
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Predictive value of primary fluorine-18 fluorodeoxyglucose standard uptake value for a better choice of systematic nodal dissection or sampling in clinical stage ia non--small-cell lung cancer.
    Li X; Zhang H; Xing L; Xu X; Xie P; Ma H; Zhang L; Chen M; Sun X; Xu W; Chen L; Yu J
    Clin Lung Cancer; 2013 Sep; 14(5):568-73. PubMed ID: 23835164
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The maximum standardized uptake value of fluorodeoxyglucose positron emission tomography of the primary tumour is a good predictor of pathological nodal involvement in clinical N0 non-small-cell lung cancer.
    Miyasaka Y; Suzuki K; Takamochi K; Matsunaga T; Oh S
    Eur J Cardiothorac Surg; 2013 Jul; 44(1):83-7. PubMed ID: 23233074
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Use of maximum standardized uptake value on fluorodeoxyglucose positron-emission tomography in predicting lymph node involvement in patients with primary non-small cell lung cancer.
    Muto J; Hida Y; Kaga K; Ohtaka K; Okamoto S; Tamaki N; Nakada-Kubota R; Hirano S; Matsui Y
    Anticancer Res; 2014 Feb; 34(2):805-10. PubMed ID: 24511016
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Diagnostic accuracy of virtual 18F-FDG PET/CT bronchoscopy for the detection of lymph node metastases in non-small cell lung cancer patients.
    Herbrik M; Treffert J; Geiger B; Riegger C; Hartung V; Rosenbaum-Krumme SJ; Forsting M; Antoch G; Heusner TA
    J Nucl Med; 2011 Oct; 52(10):1520-5. PubMed ID: 21908390
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Advantages of diffusion-weighted imaging over positron emission tomography-computed tomography in assessment of hilar and mediastinal lymph node in lung cancer.
    Usuda K; Sagawa M; Motono N; Ueno M; Tanaka M; Machida Y; Matoba M; Kuginuki Y; Taniguchi M; Ueda Y; Sakuma T
    Ann Surg Oncol; 2013 May; 20(5):1676-83. PubMed ID: 23242821
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 29.