266 related articles for article (PubMed ID: 25861691)
1. Influence of underpreparation on primary stability of implants inserted in poor quality bone sites: an in vitro study.
Degidi M; Daprile G; Piattelli A
J Oral Maxillofac Surg; 2015 Jun; 73(6):1084-8. PubMed ID: 25861691
[TBL] [Abstract][Full Text] [Related]
2. Influence of Stepped Osteotomy on Primary Stability of Implants Inserted in Low-Density Bone Sites: An In Vitro Study.
Degidi M; Daprile G; Piattelli A
Int J Oral Maxillofac Implants; 2017; 32(1):37-41. PubMed ID: 28095514
[TBL] [Abstract][Full Text] [Related]
3. Differences in implant stability associated with various methods of preparation of the implant bed: an in vitro study.
Ahn SJ; Leesungbok R; Lee SW; Heo YK; Kang KL
J Prosthet Dent; 2012 Jun; 107(6):366-72. PubMed ID: 22633592
[TBL] [Abstract][Full Text] [Related]
4. Influence of surgical technique and surface roughness on the primary stability of an implant in artificial bone with different cortical thickness: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2010 Feb; 21(2):213-20. PubMed ID: 20070754
[TBL] [Abstract][Full Text] [Related]
5. Torque-fitting and resonance frequency analyses of implants in conventional sockets versus controlled bone defects in vitro.
Akça K; Kökat AM; Cömert A; Akkocaoğlu M; Tekdemir I; Cehreli MC
Int J Oral Maxillofac Surg; 2010 Feb; 39(2):169-73. PubMed ID: 20036107
[TBL] [Abstract][Full Text] [Related]
6. Undersized implant site preparation to enhance primary implant stability in poor bone density: a prospective clinical study.
Alghamdi H; Anand PS; Anil S
J Oral Maxillofac Surg; 2011 Dec; 69(12):e506-12. PubMed ID: 22117707
[TBL] [Abstract][Full Text] [Related]
7. Primary stability determination by means of insertion torque and RFA in a sample of 4,135 implants.
Degidi M; Daprile G; Piattelli A
Clin Implant Dent Relat Res; 2012 Aug; 14(4):501-7. PubMed ID: 20849539
[TBL] [Abstract][Full Text] [Related]
8. Influence of the surgical technique and surface roughness on the primary stability of an implant in artificial bone with a density equivalent to maxillary bone: a laboratory study.
Tabassum A; Meijer GJ; Wolke JG; Jansen JA
Clin Oral Implants Res; 2009 Apr; 20(4):327-32. PubMed ID: 19298286
[TBL] [Abstract][Full Text] [Related]
9. Influence of Cortical Layer and Surgical Techniques on the Primary Implant Stability in Low-density Bone: An
Shafiullah R; Hariharan R; Krishnan CS; Azhagarasan NS; Jayakrishnakumar S; Saravanakumar M
J Contemp Dent Pract; 2021 Feb; 22(2):146-151. PubMed ID: 34257173
[TBL] [Abstract][Full Text] [Related]
10. Primary Stability Evaluation of a Novel Tapered Implant Inserted in Low-Density Bone Sites: An In Vitro Study.
Degidi M; Daprile G
Int J Oral Maxillofac Implants; 2023; 38(2):334-337. PubMed ID: 37083906
[No Abstract] [Full Text] [Related]
11. Evaluation of primary and secondary stability of titanium implants using different surgical techniques.
Tabassum A; Meijer GJ; Walboomers XF; Jansen JA
Clin Oral Implants Res; 2014 Apr; 25(4):487-92. PubMed ID: 23638908
[TBL] [Abstract][Full Text] [Related]
12. Adapted preparation technique for screw-type implants: explorative in vitro pilot study in a porcine bone model.
Beer A; Gahleitner A; Holm A; Birkfellner W; Homolka P
Clin Oral Implants Res; 2007 Feb; 18(1):103-7. PubMed ID: 17224030
[TBL] [Abstract][Full Text] [Related]
13. Development of a new implant primary stability parameter: insertion torque revisited.
Degidi M; Daprile G; Piattelli A; Iezzi G
Clin Implant Dent Relat Res; 2013 Oct; 15(5):637-44. PubMed ID: 22008885
[TBL] [Abstract][Full Text] [Related]
14. Influence of defect depth on resonance frequency analysis and insertion torque values for implants placed in fresh extraction sockets: a human cadaver study.
Turkyilmaz I; Sennerby L; Yilmaz B; Bilecenoglu B; Ozbek EN
Clin Implant Dent Relat Res; 2009 Mar; 11(1):52-8. PubMed ID: 18384400
[TBL] [Abstract][Full Text] [Related]
15. Implant primary stability determined by resonance frequency analysis: correlation with insertion torque, histologic bone volume, and torsional stability at 6 weeks.
Makary C; Rebaudi A; Sammartino G; Naaman N
Implant Dent; 2012 Dec; 21(6):474-80. PubMed ID: 23149504
[TBL] [Abstract][Full Text] [Related]
16. Determination of primary stability: a comparison of the surgeon's perception and objective measurements.
Degidi M; Daprile G; Piattelli A
Int J Oral Maxillofac Implants; 2010; 25(3):558-61. PubMed ID: 20556255
[TBL] [Abstract][Full Text] [Related]
17. Comparison of conventional twist drill protocol and piezosurgery for implant insertion: an ex vivo study on different bone types.
Sagheb K; Kumar VV; Azaripour A; Walter C; Al-Nawas B; Kämmerer PW
Clin Oral Implants Res; 2017 Feb; 28(2):207-213. PubMed ID: 26799448
[TBL] [Abstract][Full Text] [Related]
18. A correlation between bone (B), insertion torque (IT), and implant stability (S): BITS score.
Herekar M; Sethi M; Ahmad T; Fernandes AS; Patil V; Kulkarni H
J Prosthet Dent; 2014 Oct; 112(4):805-10. PubMed ID: 24726588
[TBL] [Abstract][Full Text] [Related]
19. Biomechanical aspects of primary implant stability: a human cadaver study.
Turkyilmaz I; Sennerby L; McGlumphy EA; Tözüm TF
Clin Implant Dent Relat Res; 2009 Jun; 11(2):113-9. PubMed ID: 18422713
[TBL] [Abstract][Full Text] [Related]
20. Influence of surgical technique, implant shape and diameter on the primary stability in cancellous bone.
Bilhan H; Geckili O; Mumcu E; Bozdag E; Sünbüloğlu E; Kutay O
J Oral Rehabil; 2010 Dec; 37(12):900-7. PubMed ID: 20529176
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]