These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

168 related articles for article (PubMed ID: 25862603)

  • 1. Bioprosthetic valve thrombosis: The eyes will not see what the mind does not know.
    Pislaru SV; Pellikka PA; Schaff HV; Connolly HM
    J Thorac Cardiovasc Surg; 2015 Jun; 149(6):e86-7. PubMed ID: 25862603
    [No Abstract]   [Full Text] [Related]  

  • 2. Early stenosis of an aortic porcine bioprosthesis due to thrombosis: Case report and literature review.
    Dohi M; Doi K; Yaku H
    J Thorac Cardiovasc Surg; 2015 Jun; 149(6):e83-6. PubMed ID: 25816961
    [No Abstract]   [Full Text] [Related]  

  • 3. Fluoroscopic characterization of surgical bioprosthetic heart valves.
    Kiefer TL; Halim S; Wang A; Kevin Harrison J; Gaca J; Hughes GC
    Catheter Cardiovasc Interv; 2015 Jun; 85(7):1274-6. PubMed ID: 25712584
    [No Abstract]   [Full Text] [Related]  

  • 4. Rebuttal: Fluoroscopic characterization of surgical bioprosthetic heart valves.
    Bapat VN; Mydin I; Chadalavada S; Tehrani H; Attia R; Thomas M
    Catheter Cardiovasc Interv; 2015 Jun; 85(7):1277-9. PubMed ID: 25712348
    [No Abstract]   [Full Text] [Related]  

  • 5. Need to identify bioprosthetic valves: a call for device reconciliation in the electronic medical record.
    Gilchrist IC
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):862-3. PubMed ID: 23526620
    [No Abstract]   [Full Text] [Related]  

  • 6. Aortic bioprosthesis--avoid obstructive properties due to thrombosis as altered durability due to structural valve deterioration.
    Jamieson WR; Fradet GJ
    J Thorac Cardiovasc Surg; 2010 May; 139(5):1354. PubMed ID: 20412968
    [No Abstract]   [Full Text] [Related]  

  • 7. Bioprosthetic aortic valve replacement on a mechanical valve ring.
    Ashraf O; Yadav S
    Asian Cardiovasc Thorac Ann; 2015 Nov; 23(9):1060-1. PubMed ID: 24732085
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Analysis of Bioprosthetic Aortic Valve Thrombosis-Implications and Management Strategies.
    Núñez-Gil IJ; Alkhouli M; Centola M; Feltes G; Villablanca P; Ramakrishna H
    J Cardiothorac Vasc Anesth; 2019 Oct; 33(10):2853-2860. PubMed ID: 30455145
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Valve-in-valve implantation of Medtronic CoreValve prosthesis in patients with failing bioprosthetic aortic valves.
    Linke A; Woitek F; Merx MW; Schiefer C; Möbius-Winkler S; Holzhey D; Rastan A; Ender J; Walther T; Kelm M; Mohr FW; Schuler G
    Circ Cardiovasc Interv; 2012 Oct; 5(5):689-97. PubMed ID: 23048050
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Treatment of a failing St. Jude Medical Trifecta by Medtronic Corevalve Evolut valve-in-valve implantation.
    Haussig S; Schuler G; Linke A
    JACC Cardiovasc Interv; 2014 Jul; 7(7):e81-2. PubMed ID: 24954575
    [No Abstract]   [Full Text] [Related]  

  • 11. Early postoperative thrombosis of an aortic bioprosthetic valve: should anticoagulation be patient specific?
    Efthymiou CA; Mills RJ; O'Regan DJ
    J Card Surg; 2013 Nov; 28(6):723-9. PubMed ID: 23992398
    [TBL] [Abstract][Full Text] [Related]  

  • 12. A guide to fluoroscopic identification and design of bioprosthetic valves: a reference for valve-in-valve procedure.
    Bapat V; Mydin I; Chadalavada S; Tehrani H; Attia R; Thomas M
    Catheter Cardiovasc Interv; 2013 Apr; 81(5):853-61. PubMed ID: 22431472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Transcatheter aortic valve implantation with a Sapien 3 Commander 20 mm valves in patients with degenerated 19 mm bioprosthetic aortic valve.
    Loyalka P; Nascimbene A; Schechter M; Petrovic M; Sundara Raman A; Gregoric ID; Kar B
    Catheter Cardiovasc Interv; 2017 Jun; 89(7):1280-1285. PubMed ID: 27696659
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Early structural valve deterioration of the Trifecta aortic valve biological prosthesis: a word of caution.
    Saxena P; Greason KL; Schaff HV
    J Thorac Cardiovasc Surg; 2014 Jan; 147(1):e10-1. PubMed ID: 24041765
    [No Abstract]   [Full Text] [Related]  

  • 15. Transfemoral transcatheter valve-in-valve-in-valve replacement.
    Leung Wai Sang S; Giri J; Vallabhajosyula P
    J Thorac Cardiovasc Surg; 2016 Aug; 152(2):622-3. PubMed ID: 27179844
    [No Abstract]   [Full Text] [Related]  

  • 16. Sutureless aortic valve replacement to prevent patient-prosthesis mismatch in the era of valve-in-valve implantation.
    Santarpino G; Pfeiffer S; Fischlein T
    J Thorac Cardiovasc Surg; 2012 Jul; 144(1):279-80. PubMed ID: 22710046
    [No Abstract]   [Full Text] [Related]  

  • 17. Acute bioprosthetic thrombosis immediately after aortic valve replacement.
    Patanè F; Sansone F; Campanella A; Asteggiano F; Rinaldi M
    J Cardiovasc Med (Hagerstown); 2009 Feb; 10(2):167-9. PubMed ID: 19194176
    [TBL] [Abstract][Full Text] [Related]  

  • 18. eComment. Trifecta: the latest generation of bioprosthetic aortic valves.
    Hajj-Chahine J
    Interact Cardiovasc Thorac Surg; 2013 Oct; 17(4):672-3. PubMed ID: 24065754
    [No Abstract]   [Full Text] [Related]  

  • 19. Transcatheter Replacement of Failed Bioprosthetic Valves: Large Multicenter Assessment of the Effect of Implantation Depth on Hemodynamics After Aortic Valve-in-Valve.
    Simonato M; Webb J; Kornowski R; Vahanian A; Frerker C; Nissen H; Bleiziffer S; Duncan A; Rodés-Cabau J; Attizzani GF; Horlick E; Latib A; Bekeredjian R; Barbanti M; Lefevre T; Cerillo A; Hernández JM; Bruschi G; Spargias K; Iadanza A; Brecker S; Palma JH; Finkelstein A; Abdel-Wahab M; Lemos P; Petronio AS; Champagnac D; Sinning JM; Salizzoni S; Napodano M; Fiorina C; Marzocchi A; Leon M; Dvir D
    Circ Cardiovasc Interv; 2016 Jun; 9(6):. PubMed ID: 27301396
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Relation between hemodynamic behavior and occurrence of early stenotic failure of bioprostheses.
    Meuris B; Flameng W
    J Thorac Cardiovasc Surg; 2010 Nov; 140(5):1200; author reply 1200-1. PubMed ID: 20951264
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 9.