These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

187 related articles for article (PubMed ID: 25867934)

  • 21. Quantification of soft tissue artefact in motion analysis by combining 3D fluoroscopy and stereophotogrammetry: a study on two subjects.
    Stagni R; Fantozzi S; Cappello A; Leardini A
    Clin Biomech (Bristol, Avon); 2005 Mar; 20(3):320-9. PubMed ID: 15698706
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Quantification of the 3D relative movement of external marker sets vs. bones based on magnetic resonance imaging.
    Sangeux M; Marin F; Charleux F; Dürselen L; Ho Ba Tho MC
    Clin Biomech (Bristol, Avon); 2006 Nov; 21(9):984-91. PubMed ID: 16844273
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Effects of soft tissue artifacts on the calculated kinematics and kinetics of the knee during stair-ascent.
    Tsai TY; Lu TW; Kuo MY; Lin CC
    J Biomech; 2011 Apr; 44(6):1182-8. PubMed ID: 21296352
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Investigation of soft tissue movement during level walking: translations and rotations of skin markers.
    Gao B; Zheng NN
    J Biomech; 2008 Nov; 41(15):3189-95. PubMed ID: 18930462
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Do kinematic models reduce the effects of soft tissue artefacts in skin marker-based motion analysis? An in vivo study of knee kinematics.
    Andersen MS; Benoit DL; Damsgaard M; Ramsey DK; Rasmussen J
    J Biomech; 2010 Jan; 43(2):268-73. PubMed ID: 19879581
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Standardization proposal of soft tissue artefact description for data sharing in human motion measurements.
    Cereatti A; Bonci T; Akbarshahi M; Aminian K; Barré A; Begon M; Benoit DL; Charbonnier C; Dal Maso F; Fantozzi S; Lin CC; Lu TW; Pandy MG; Stagni R; van den Bogert AJ; Camomilla V
    J Biomech; 2017 Sep; 62():5-13. PubMed ID: 28259462
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Comparison of soft tissue artifact and its effects on knee kinematics between non-obese and obese subjects performing a squatting activity recorded using an exoskeleton.
    Clément J; de Guise JA; Fuentes A; Hagemeister N
    Gait Posture; 2018 Mar; 61():197-203. PubMed ID: 29353745
    [TBL] [Abstract][Full Text] [Related]  

  • 28. A reproducible method for studying three-dimensional knee kinematics.
    Hagemeister N; Parent G; Van de Putte M; St-Onge N; Duval N; de Guise J
    J Biomech; 2005 Sep; 38(9):1926-31. PubMed ID: 15996675
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Effects of the soft tissue artefact on the hip joint kinematics during unrestricted activities of daily living.
    D'Isidoro F; Brockmann C; Ferguson SJ
    J Biomech; 2020 May; 104():109717. PubMed ID: 32234246
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Influence of soft tissue artifacts on the calculated kinematics and kinetics of total knee replacements during sit-to-stand.
    Kuo MY; Tsai TY; Lin CC; Lu TW; Hsu HC; Shen WC
    Gait Posture; 2011 Mar; 33(3):379-84. PubMed ID: 21227694
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Effects of soft tissue artifacts on the calculated kinematics of the knee during walking and running.
    Wang W; Li X; Zhang T; Li J; Viellehner J; Komnik I; Wang S; Potthast W
    J Biomech; 2023 Mar; 150():111474. PubMed ID: 36871431
    [TBL] [Abstract][Full Text] [Related]  

  • 32. In situ comparison of A-mode ultrasound tracking system and skin-mounted markers for measuring kinematics of the lower extremity.
    Niu K; Anijs T; Sluiter V; Homminga J; Sprengers A; Marra MA; Verdonschot N
    J Biomech; 2018 Apr; 72():134-143. PubMed ID: 29573792
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Model of soft tissue artifact propagation to joint angles in human movement analysis.
    Page Á; de Rosario H; Mata V; Besa A
    J Biomech Eng; 2014 Mar; 136(3):034502. PubMed ID: 24337143
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sensitivity of tibio-menisco-femoral joint contact behavior to variations in knee kinematics.
    Yao J; Salo AD; Lee J; Lerner AL
    J Biomech; 2008; 41(2):390-8. PubMed ID: 17950743
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Soft tissue artifact assessment during treadmill walking in subjects with total knee arthroplasty.
    Barre A; Thiran JP; Jolles BM; Theumann N; Aminian K
    IEEE Trans Biomed Eng; 2013 Nov; 60(11):3131-40. PubMed ID: 23782791
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Soft tissue artifact causes significant errors in the calculation of joint angles and range of motion at the hip.
    Fiorentino NM; Atkins PR; Kutschke MJ; Goebel JM; Foreman KB; Anderson AE
    Gait Posture; 2017 Jun; 55():184-190. PubMed ID: 28475981
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Development and evaluation of a new methodology for Soft Tissue Artifact compensation in the lower limb.
    Lahkar BK; Rohan PY; Assi A; Pillet H; Bonnet X; Thoreux P; Skalli W
    J Biomech; 2021 Jun; 122():110464. PubMed ID: 33932915
    [TBL] [Abstract][Full Text] [Related]  

  • 38. A linear soft tissue artefact model for human movement analysis: proof of concept using in vivo data.
    Andersen MS; Damsgaard M; Rasmussen J; Ramsey DK; Benoit DL
    Gait Posture; 2012 Apr; 35(4):606-11. PubMed ID: 22225853
    [TBL] [Abstract][Full Text] [Related]  

  • 39. A hip joint kinematics driven model for the generation of realistic thigh soft tissue artefacts.
    Camomilla V; Cereatti A; Chèze L; Cappozzo A
    J Biomech; 2013 Feb; 46(3):625-30. PubMed ID: 23116764
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Three-dimensional kinematics of the human knee with intracortical pin fixation.
    Ishii Y; Terajima K; Terashima S; Koga Y
    Clin Orthop Relat Res; 1997 Oct; (343):144-50. PubMed ID: 9345219
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 10.