BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

171 related articles for article (PubMed ID: 25875177)

  • 1. Objective assessment and design improvement of a staring, sparse transducer array by the spatial crosstalk matrix for 3D photoacoustic tomography.
    Wong P; Kosik I; Raess A; Carson JJ
    PLoS One; 2015; 10(4):e0124759. PubMed ID: 25875177
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Acoustically penetrable optical reflector for photoacoustic tomography.
    Deng Z; Zhao H; Ren Q; Li C
    J Biomed Opt; 2013 Jul; 18(7):070503. PubMed ID: 23839486
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Design and evaluation of a hybrid photoacoustic tomography and diffuse optical tomography system for breast cancer detection.
    Xi L; Li X; Yao L; Grobmyer S; Jiang H
    Med Phys; 2012 May; 39(5):2584-94. PubMed ID: 22559629
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Individual transducer impulse response characterization method to improve image quality of array-based handheld optoacoustic tomography.
    Chowdhury KB; Bader M; Dehner C; Jüstel D; Ntziachristos V
    Opt Lett; 2021 Jan; 46(1):1-4. PubMed ID: 33362000
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Photoacoustic tomography imaging using a 4f acoustic lens and peak-hold technology.
    Wei Y; Tang Z; Zhang H; He Y; Liu H
    Opt Express; 2008 Apr; 16(8):5314-9. PubMed ID: 18542633
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Monolithic Multiband CMUTs for Photoacoustic Computed Tomography With In Vivo Biological Tissue Imaging.
    Pun SH; Yu Y; Zhang J; Wang J; Cheng CH; Lei KF; Yuan Z; Mak PU
    IEEE Trans Ultrason Ferroelectr Freq Control; 2018 Mar; 65(3):465-475. PubMed ID: 29505413
    [TBL] [Abstract][Full Text] [Related]  

  • 7. An adaptive filtered back-projection for photoacoustic image reconstruction.
    Huang H; Bustamante G; Peterson R; Ye JY
    Med Phys; 2015 May; 42(5):2169-78. PubMed ID: 25979011
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Use of acoustic reflector to make a compact photoacoustic tomography system.
    Kalva SK; Pramanik M
    J Biomed Opt; 2017 Feb; 22(2):26009. PubMed ID: 28241275
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Slit-enabled linear-array photoacoustic tomography with near isotropic spatial resolution in three dimensions.
    Wang Y; Wang D; Zhang Y; Geng J; Lovell JF; Xia J
    Opt Lett; 2016 Jan; 41(1):127-30. PubMed ID: 26696175
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Development of a multi-band photoacoustic tomography imaging system based on a capacitive micromachined ultrasonic transducer array.
    Zhang J; Pun SH; Yu Y; Gao D; Wang J; Mak PU; Lei KF; Cheng CH; Yuan Z
    Appl Opt; 2017 May; 56(14):4012-4018. PubMed ID: 29047533
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accelerated high-resolution photoacoustic tomography via compressed sensing.
    Arridge S; Beard P; Betcke M; Cox B; Huynh N; Lucka F; Ogunlade O; Zhang E
    Phys Med Biol; 2016 Dec; 61(24):8908-8940. PubMed ID: 27910824
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Parallel acoustic delay lines for photoacoustic tomography.
    Yapici MK; Kim C; Chang CC; Jeon M; Guo Z; Cai X; Zou J; Wang LV
    J Biomed Opt; 2012 Nov; 17(11):116019. PubMed ID: 23139043
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Single-pixel camera photoacoustic tomography.
    Huynh N; Lucka F; Zhang E; Betcke M; Arridge SR; Beard PC; Cox BT
    J Biomed Opt; 2019 Sep; 24(12):1-6. PubMed ID: 31535537
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Three-dimensional photoacoustic imaging using a two-dimensional CMUT array.
    Vaithilingam S; Ma TJ; Furukawa Y; Wygant IO; Zhuang X; De La Zerda A; Oralkan O; Kamaya A; Gambhir SS; Jeffrey RB; Khuri-Yakub BT
    IEEE Trans Ultrason Ferroelectr Freq Control; 2009 Nov; 56(11):2411-9. PubMed ID: 19942528
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Wide-field three-dimensional photoacoustic/ultrasound scanner using a two-dimensional matrix transducer array.
    Kim W; Choi W; Ahn J; Lee C; Kim C
    Opt Lett; 2023 Jan; 48(2):343-346. PubMed ID: 36638453
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Development of a Compact Photoacoustic Tomography Imaging System with Dual Single-Element Transducers for Image Enhancement.
    Zhao YJ; Zhu XL; Luo PY; Li A; Xiao W; Xiao X; Liu L; Meng MQ
    Curr Med Sci; 2021 Dec; 41(6):1151-1157. PubMed ID: 34907474
    [TBL] [Abstract][Full Text] [Related]  

  • 17. All-reflective ring illumination system for photoacoustic tomography.
    Alshahrani SS; Yan Y; Alijabbari N; Pattyn A; Avrutsky I; Malyarenko E; Poudel J; Anastasio M; Mehrmohammadi M
    J Biomed Opt; 2019 Apr; 24(4):1-7. PubMed ID: 31028693
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Elevational Synthetic Aperture Focusing for Three-Dimensional Photoacoustic Imaging Using a Clinical One-Dimensional Array Transducer.
    Yoon C; Kang J; Song TK; Chang JH
    IEEE Trans Biomed Eng; 2022 Sep; 69(9):2817-2825. PubMed ID: 35226597
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Second generation slit-based photoacoustic tomography system for vascular imaging in human.
    Wang Y; Wang D; Hubbell R; Xia J
    J Biophotonics; 2017 Jun; 10(6-7):799-804. PubMed ID: 27935228
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Deep Neural Network-Based Sinogram Super-Resolution and Bandwidth Enhancement for Limited-Data Photoacoustic Tomography.
    Awasthi N; Jain G; Kalva SK; Pramanik M; Yalavarthy PK
    IEEE Trans Ultrason Ferroelectr Freq Control; 2020 Dec; 67(12):2660-2673. PubMed ID: 32142429
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.