These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

115 related articles for article (PubMed ID: 2587726)

  • 21. [MRI of the hyaline knee joint cartilages. Animal and clinical studies].
    Adam G; Prescher A; Nolte-Ernsting C; Bühne M; Scherer K; Küpper W; Günther RW
    Rofo; 1994 Feb; 160(2):143-8. PubMed ID: 8312511
    [TBL] [Abstract][Full Text] [Related]  

  • 22. [Rapid and high-resolution 3D-imaging in MR tomographic diagnosis of diseases of the knee joint].
    Skalej M; Bongers H
    Rofo; 1990 Nov; 153(5):528-34. PubMed ID: 2173057
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Accuracy and precision in the detection of articular cartilage lesions using magnetic resonance imaging at 1.5 Tesla in an in vitro study with orthopedic and histopathologic correlation.
    Schaefer FK; Kurz B; Schaefer PJ; Fuerst M; Hedderich J; Graessner J; Schuenke M; Heller H
    Acta Radiol; 2007 Dec; 48(10):1131-7. PubMed ID: 18038353
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison and reproducibility of fast and conventional spoiled gradient-echo magnetic resonance sequences in the determination of knee cartilage volume.
    Cicuttini F; Forbes A; Asbeutah A; Morris K; Stuckey S
    J Orthop Res; 2000 Jul; 18(4):580-4. PubMed ID: 11052494
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Imaging articular cartilage defects in the ankle joint with 3D fat-suppressed echo planar imaging: comparison with conventional 3D fat-suppressed gradient echo imaging.
    Ba-Ssalamah A; Schibany N; Puig S; Herneth AM; Noebauer-Huhmann IM; Trattnig S
    J Magn Reson Imaging; 2002 Aug; 16(2):209-16. PubMed ID: 12203770
    [TBL] [Abstract][Full Text] [Related]  

  • 26. [Three-dimensional MRI of the knee].
    Shahabpour M; Spruyt D; Leroux GB; Osteaux M
    Ann Radiol (Paris); 1993; 36(3):242-7. PubMed ID: 8239462
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Patellar cartilage lesions: comparison of magnetic resonance imaging and T2 relaxation-time mapping.
    Hannila I; Nieminen MT; Rauvala E; Tervonen O; Ojala R
    Acta Radiol; 2007 May; 48(4):444-8. PubMed ID: 17453527
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Experimental hyaline cartilage lesions: two-dimensional spin-echo versus three-dimensional gradient-echo MR imaging.
    Adam G; Nolte-Ernsting C; Prescher A; Bühne M; Bruchmüller K; Küpper W; Günther RW
    J Magn Reson Imaging; 1991; 1(6):665-72. PubMed ID: 1726647
    [TBL] [Abstract][Full Text] [Related]  

  • 29. MRI of the knee at 3T: first clinical results with an isotropic PDfs-weighted 3D-TSE-sequence.
    Notohamiprodjo M; Horng A; Pietschmann MF; Müller PE; Horger W; Park J; Crispin A; del Olmo JR; Weckbach S; Herrmann KA; Reiser MF; Glaser C
    Invest Radiol; 2009 Sep; 44(9):585-97. PubMed ID: 19668001
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Advanced morphological and biochemical magnetic resonance imaging of cartilage repair procedures in the knee joint at 3 Tesla.
    Welsch GH; Mamisch TC; Hughes T; Domayer S; Marlovits S; Trattnig S
    Semin Musculoskelet Radiol; 2008 Sep; 12(3):196-211. PubMed ID: 18850502
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Future of MR imaging of articular cartilage.
    Gold GE; Beaulieu CF
    Semin Musculoskelet Radiol; 2001 Dec; 5(4):313-27. PubMed ID: 11745048
    [TBL] [Abstract][Full Text] [Related]  

  • 32. 3D representation of the surface topography of normal and dysplastic trochlea using MRI.
    Biedert R; Sigg A; Gal I; Gerber H
    Knee; 2011 Oct; 18(5):340-6. PubMed ID: 20719521
    [TBL] [Abstract][Full Text] [Related]  

  • 33. 90°-flip-angle three-dimensional double-echo steady-state (3D-DESS) magnetic resonance imaging of the knee: isovoxel cartilage imaging at 3T.
    Moriya S; Miki Y; Kanagaki M; Matsuno Y; Miyati T
    Eur J Radiol; 2014 Aug; 83(8):1429-32. PubMed ID: 24882782
    [TBL] [Abstract][Full Text] [Related]  

  • 34. MR imaging of knee hyaline cartilage: evaluation of two- and three-dimensional sequences.
    Tervonen O; Dietz MJ; Carmichael SW; Ehman RL
    J Magn Reson Imaging; 1993; 3(4):663-8. PubMed ID: 8347961
    [TBL] [Abstract][Full Text] [Related]  

  • 35. New method for fast MR imaging of the knee.
    Harms SE; Flamig DP; Fisher CF; Fulmer JM
    Radiology; 1989 Dec; 173(3):743-50. PubMed ID: 2813780
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Human articular cartilage: in vitro correlation of MRI and histologic findings.
    Uhl M; Ihling C; Allmann KH; Laubenberger J; Tauer U; Adler CP; Langer M
    Eur Radiol; 1998; 8(7):1123-9. PubMed ID: 9724423
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Analysis of three-dimensional computerized representations of articular cartilage lesions.
    Lavid NE; DePaolis DC; Pope TW; Hinson GW; Munns SW; Batnitzky S; Wetzel LH; Wilkinson SB; Gordon MA
    Invest Radiol; 1996 Sep; 31(9):577-85. PubMed ID: 8877495
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Linear combination filtering for T2-selective imaging of the knee.
    Vidarsson L; Gold GE; Hargreaves B; Pauly JM
    Magn Reson Med; 2006 May; 55(5):1191-6. PubMed ID: 16586458
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Effect of gradient and section orientation on quantitative analysis of knee joint cartilage.
    Eckstein F; Stammberger T; Priebsch J; Englmeier KH; Reiser M
    J Magn Reson Imaging; 2000 Feb; 11(2):161-7. PubMed ID: 10713949
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of MR sequences in quantifying in vitro cartilage degeneration in osteoarthritis of the knee.
    Uhl M; Allmann KH; Tauer U; Laubenberger J; Adler CP; Ihling C; Langer M
    Br J Radiol; 1998 Mar; 71(843):291-6. PubMed ID: 9616238
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 6.