These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

156 related articles for article (PubMed ID: 25880679)

  • 1. Intra-cavitary ultrasound probes: cleaning and high-level disinfection are necessary for both the probe head and handle to reduce the risk of infection transmission.
    Alfa MJ
    Infect Control Hosp Epidemiol; 2015 May; 36(5):585-6. PubMed ID: 25880679
    [No Abstract]   [Full Text] [Related]  

  • 2. Reducing transmission risk through high-level disinfection of transvaginal ultrasound transducer handles.
    Ngu A; McNally G; Patel D; Gorgis V; Leroy S; Burdach J
    Infect Control Hosp Epidemiol; 2015 May; 36(5):581-4. PubMed ID: 25723900
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Is Transducer Hygiene sufficient when Vaginal Probes are used in the Clinical Routine?
    Merz E
    Ultraschall Med; 2016 Apr; 37(2):137-9. PubMed ID: 27058433
    [TBL] [Abstract][Full Text] [Related]  

  • 4. [Ultrasound guided regional anaesthesia: an effective method for cleaning the probes].
    Bloc S; Garnier T; Bounhiol C; Komly B; Machado G; Leclerc P; Roy M; Mercadal L; Demontoux V; Morel B; Ecoffey C; Dhonneur G
    Ann Fr Anesth Reanim; 2008 Dec; 27(12):994-8. PubMed ID: 19026515
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Emergency department ultrasonographic probe contamination and experimental model of probe disinfection.
    Frazee BW; Fahimi J; Lambert L; Nagdev A
    Ann Emerg Med; 2011 Jul; 58(1):56-63. PubMed ID: 21256624
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Evaluation of ultraviolet C for disinfection of endocavitary ultrasound transducers persistently contaminated despite probe covers.
    Kac G; Podglajen I; Si-Mohamed A; Rodi A; Grataloup C; Meyer G
    Infect Control Hosp Epidemiol; 2010 Feb; 31(2):165-70. PubMed ID: 20025531
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Evaluation of a new disinfection method for ultrasound probes used for regional anesthesia: ultraviolet C light.
    Bloc S; Mercadal L; Garnier T; Komly B; Leclerc P; Morel B; Ecoffey C; Dhonneur G
    J Ultrasound Med; 2011 Jun; 30(6):785-8. PubMed ID: 21632992
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Cleaning methods for ultrasound probes.
    Mirza WA; Imam SH; Kharal MS; Aslam M; Ali SA; Masroor I; Ahmad MN
    J Coll Physicians Surg Pak; 2008 May; 18(5):286-9. PubMed ID: 18541083
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Transvaginal ultrasound probes are human papillomavirus-free following low-level disinfection: cross-sectional multicenter survey.
    Lucet JC; Heard I; Roueli A; Lafourcade A; Mandelbrot L; Estellat C; Dommergues M;
    Ultrasound Obstet Gynecol; 2019 Nov; 54(5):688-695. PubMed ID: 30908769
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Does improving surface cleaning and disinfection reduce health care-associated infections?
    Donskey CJ
    Am J Infect Control; 2013 May; 41(5 Suppl):S12-9. PubMed ID: 23465603
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Study on a New Ultraviolet Sterilizer to the Surface Disinfection of the Ultrasound Probe.
    Chen GQ; Chen YH; Yi L; Yin J; Gao Q; Song JN; Li SK; Chen PH; Guo GP
    Biomed Environ Sci; 2018 Feb; 31(2):163-167. PubMed ID: 29606197
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Sterilization, high-level disinfection, and environmental cleaning.
    Rutala WA; Weber DJ
    Infect Dis Clin North Am; 2011 Mar; 25(1):45-76. PubMed ID: 21315994
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Perioral stains after ortho-phthalaldehyde disinfection of echo probes.
    Streckenbach SC; Alston TA
    Anesthesiology; 2003 Oct; 99(4):1032. PubMed ID: 14508346
    [No Abstract]   [Full Text] [Related]  

  • 14. Letter to the editor: does the use of ultrasound affect contamination of musculoskeletal injections sites?
    Ata AM; Onat ŞŞ; Özçakar L
    Clin Orthop Relat Res; 2015 Jan; 473(1):390. PubMed ID: 25342009
    [No Abstract]   [Full Text] [Related]  

  • 15. Emergency department ultrasound infection control: do unto (and into) others.
    Talan DA; Partida CN
    Ann Emerg Med; 2011 Jul; 58(1):64-6. PubMed ID: 21492960
    [No Abstract]   [Full Text] [Related]  

  • 16. A safe and practical decontamination method to reduce the risk of bacterial colonization of ultrasound transducers.
    Ejtehadi F; Ejtehadi F; Teb JC; Arasteh MM
    J Clin Ultrasound; 2014 Sep; 42(7):395-8. PubMed ID: 24615794
    [TBL] [Abstract][Full Text] [Related]  

  • 17. [Ultrasound equipment in anaesthesia and infection control measures].
    Hajjar J; Mounier M
    Ann Fr Anesth Reanim; 2009 Apr; 28(4):397-8. PubMed ID: 19324512
    [No Abstract]   [Full Text] [Related]  

  • 18. Barriers and facilitators to standardization of ultrasound use and probe disinfection in the ambulatory setting.
    Ai A; Anderson L; Safdar N; Shirley D
    Infect Control Hosp Epidemiol; 2020 Apr; 41(4):469-471. PubMed ID: 32036803
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Medical Ultrasound Disinfection and Hygiene Practices: WFUMB Global Survey Results.
    Westerway SC; Basseal JM; Abramowicz JS
    Ultrasound Med Biol; 2019 Feb; 45(2):344-352. PubMed ID: 30409470
    [TBL] [Abstract][Full Text] [Related]  

  • 20. US probes: risk of cross infection and ways to reduce it--comparison of cleaning methods.
    Fowler C; McCracken D
    Radiology; 1999 Oct; 213(1):299-300. PubMed ID: 10540675
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.