BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

259 related articles for article (PubMed ID: 25885056)

  • 21. Integrating CT Myocardial Perfusion and CT-FFR in the Work-Up of Coronary Artery Disease.
    Coenen A; Rossi A; Lubbers MM; Kurata A; Kono AK; Chelu RG; Segreto S; Dijkshoorn ML; Wragg A; van Geuns RM; Pugliese F; Nieman K
    JACC Cardiovasc Imaging; 2017 Jul; 10(7):760-770. PubMed ID: 28109933
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Fully quantitative pixel-wise analysis of cardiovascular magnetic resonance perfusion improves discrimination of dark rim artifact from perfusion defects associated with epicardial coronary stenosis.
    Ta AD; Hsu LY; Conn HM; Winkler S; Greve AM; Shanbhag SM; Chen MY; Patricia Bandettini W; Arai AE
    J Cardiovasc Magn Reson; 2018 Mar; 20(1):16. PubMed ID: 29514708
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Estimating coronary blood flow using CT transluminal attenuation flow encoding: Formulation, preclinical validation, and clinical feasibility.
    Lardo AC; Rahsepar AA; Seo JH; Eslami P; Korley F; Kishi S; Abd T; Mittal R; George RT
    J Cardiovasc Comput Tomogr; 2015; 9(6):559-66.e1. PubMed ID: 26460186
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Fully automated, inline quantification of myocardial blood flow with cardiovascular magnetic resonance: repeatability of measurements in healthy subjects.
    Brown LAE; Onciul SC; Broadbent DA; Johnson K; Fent GJ; Foley JRJ; Garg P; Chew PG; Knott K; Dall'Armellina E; Swoboda PP; Xue H; Greenwood JP; Moon JC; Kellman P; Plein S
    J Cardiovasc Magn Reson; 2018 Jul; 20(1):48. PubMed ID: 29983119
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of dual to single contrast bolus magnetic resonance myocardial perfusion imaging for detection of significant coronary artery disease.
    Groothuis JG; Kremers FP; Beek AM; Brinckman SL; Tuinenburg AC; Jerosch-Herold M; van Rossum AC; Hofman MB
    J Magn Reson Imaging; 2010 Jul; 32(1):88-93. PubMed ID: 20578015
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Quantitative pixel-wise measurement of myocardial blood flow: the impact of surface coil-related field inhomogeneity and a comparison of methods for its correction.
    Miller CA; Hsu LY; Ta A; Conn H; Winkler S; Arai AE
    J Cardiovasc Magn Reson; 2015 Feb; 17(1):11. PubMed ID: 25827156
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Stress Perfusion CMR in Patients With Known and Suspected CAD: Prognostic Value and Optimal Ischemic Threshold for Revascularization.
    Vincenti G; Masci PG; Monney P; Rutz T; Hugelshofer S; Gaxherri M; Muller O; Iglesias JF; Eeckhout E; Lorenzoni V; Pellaton C; Sierro C; Schwitter J
    JACC Cardiovasc Imaging; 2017 May; 10(5):526-537. PubMed ID: 28412420
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Diagnostic Performance of Fully Automated Pixel-Wise Quantitative Myocardial Perfusion Imaging by Cardiovascular Magnetic Resonance.
    Hsu LY; Jacobs M; Benovoy M; Ta AD; Conn HM; Winkler S; Greve AM; Chen MY; Shanbhag SM; Bandettini WP; Arai AE
    JACC Cardiovasc Imaging; 2018 May; 11(5):697-707. PubMed ID: 29454767
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Quantitative assessment of magnetic resonance derived myocardial perfusion measurements using advanced techniques: microsphere validation in an explanted pig heart system.
    Schuster A; Zarinabad N; Ishida M; Sinclair M; van den Wijngaard JP; Morton G; Hautvast GL; Bigalke B; van Horssen P; Smith N; Spaan JA; Siebes M; Chiribiri A; Nagel E
    J Cardiovasc Magn Reson; 2014 Oct; 16(1):82. PubMed ID: 25315438
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Advances in Myocardial Perfusion MR Imaging: Physiological Implications, the Importance of Quantitative Analysis, and Impact on Patient Care in Coronary Artery Disease.
    Sakuma H; Ishida M
    Magn Reson Med Sci; 2022 Mar; 21(1):195-211. PubMed ID: 34108304
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Routine Clinical Quantitative Rest Stress Myocardial Perfusion for Managing Coronary Artery Disease: Clinical Relevance of Test-Retest Variability.
    Kitkungvan D; Johnson NP; Roby AE; Patel MB; Kirkeeide R; Gould KL
    JACC Cardiovasc Imaging; 2017 May; 10(5):565-577. PubMed ID: 28017383
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Adenosine triphosphate (ATP) and adenosine cause similar vasodilator effect in patients undergoing stress perfusion cardiac magnetic resonance imaging.
    García-Baizán A; Millor M; Bartolomé P; Ezponda A; Pueyo JC; Gavira JJ; Bastarrika G
    Int J Cardiovasc Imaging; 2019 Apr; 35(4):675-682. PubMed ID: 30426300
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Absolute quantification of myocardial blood flow with constrained estimation of the arterial input function.
    Fluckiger JU; Benefield BC; Harris KR; Lee DC
    J Magn Reson Imaging; 2013 Sep; 38(3):603-9. PubMed ID: 23371884
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Coronary microvascular function and myocardial fibrosis in women with angina pectoris and no obstructive coronary artery disease: the iPOWER study.
    Mygind ND; Michelsen MM; Pena A; Qayyum AA; Frestad D; Christensen TE; Ghotbi AA; Dose N; Faber R; Vejlstrup N; Hasbak P; Kjaer A; Prescott E; Kastrup J;
    J Cardiovasc Magn Reson; 2016 Nov; 18(1):76. PubMed ID: 27809867
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Stress Computed Tomography Perfusion Versus Fractional Flow Reserve CT Derived in Suspected Coronary Artery Disease: The PERFECTION Study.
    Pontone G; Baggiano A; Andreini D; Guaricci AI; Guglielmo M; Muscogiuri G; Fusini L; Fazzari F; Mushtaq S; Conte E; Calligaris G; De Martini S; Ferrari C; Galli S; Grancini L; Ravagnani P; Teruzzi G; Trabattoni D; Fabbiocchi F; Lualdi A; Montorsi P; Rabbat MG; Bartorelli AL; Pepi M
    JACC Cardiovasc Imaging; 2019 Aug; 12(8 Pt 1):1487-1497. PubMed ID: 30343073
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Diagnostic Accuracy of Fast Computational Approaches to Derive Fractional Flow Reserve From Diagnostic Coronary Angiography: The International Multicenter FAVOR Pilot Study.
    Tu S; Westra J; Yang J; von Birgelen C; Ferrara A; Pellicano M; Nef H; Tebaldi M; Murasato Y; Lansky A; Barbato E; van der Heijden LC; Reiber JHC; Holm NR; Wijns W;
    JACC Cardiovasc Interv; 2016 Oct; 9(19):2024-2035. PubMed ID: 27712739
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Quantitative three-dimensional cardiovascular magnetic resonance myocardial perfusion imaging in systole and diastole.
    Motwani M; Kidambi A; Sourbron S; Fairbairn TA; Uddin A; Kozerke S; Greenwood JP; Plein S
    J Cardiovasc Magn Reson; 2014 Feb; 16(1):19. PubMed ID: 24565078
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Relative flow reserve derived from quantitative perfusion imaging may not outperform stress myocardial blood flow for identification of hemodynamically significant coronary artery disease.
    Stuijfzand WJ; Uusitalo V; Kero T; Danad I; Rijnierse MT; Saraste A; Raijmakers PG; Lammertsma AA; Harms HJ; Heymans MW; Huisman MC; Marques KM; Kajander SA; Pietilä M; Sörensen J; van Royen N; Knuuti J; Knaapen P
    Circ Cardiovasc Imaging; 2015 Jan; 8(1):. PubMed ID: 25596142
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Quantitative myocardial first-pass cardiovascular magnetic resonance perfusion imaging using hyperpolarized [1-
    Fuetterer M; Busch J; Traechtler J; Wespi P; Peereboom SM; Sauer M; Lipiski M; Fleischmann T; Cesarovic N; Stoeck CT; Kozerke S
    J Cardiovasc Magn Reson; 2018 Nov; 20(1):73. PubMed ID: 30415642
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Myocardial blood flow at rest and stress measured with dynamic contrast-enhanced MRI: comparison of a distributed parameter model with a Fermi function model.
    Broadbent DA; Biglands JD; Larghat A; Sourbron SP; Radjenovic A; Greenwood JP; Plein S; Buckley DL
    Magn Reson Med; 2013 Dec; 70(6):1591-7. PubMed ID: 23417985
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 13.