These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
2. Cardiac T2-mapping using a fast gradient echo spin echo sequence - first in vitro and in vivo experience. Baeßler B; Schaarschmidt F; Stehning C; Schnackenburg B; Maintz D; Bunck AC J Cardiovasc Magn Reson; 2015 Aug; 17(1):67. PubMed ID: 26231927 [TBL] [Abstract][Full Text] [Related]
3. Fast T2 gradient-spin-echo (T2-GraSE) mapping for myocardial edema quantification: first in vivo validation in a porcine model of ischemia/reperfusion. Fernández-Jiménez R; Sánchez-González J; Aguero J; Del Trigo M; Galán-Arriola C; Fuster V; Ibáñez B J Cardiovasc Magn Reson; 2015 Nov; 17():92. PubMed ID: 26538198 [TBL] [Abstract][Full Text] [Related]
4. A single-shot T Chu ML; Chang HC; Oshio K; Chen NK Magn Reson Med; 2018 Jan; 79(1):383-393. PubMed ID: 28480603 [TBL] [Abstract][Full Text] [Related]
5. A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart. Keerthivasan MB; Mandava S; Johnson K; Avery R; Janardhanan R; Martin DR; Bilgin A; Altbach MI J Cardiovasc Magn Reson; 2018 Jul; 20(1):49. PubMed ID: 30025523 [TBL] [Abstract][Full Text] [Related]
6. Tissue characterization by T1 and T2 mapping cardiovascular magnetic resonance imaging to monitor myocardial inflammation in healing myocarditis. Bohnen S; Radunski UK; Lund GK; Ojeda F; Looft Y; Senel M; Radziwolek L; Avanesov M; Tahir E; Stehning C; Schnackenburg B; Adam G; Blankenberg S; Muellerleile K Eur Heart J Cardiovasc Imaging; 2017 Jul; 18(7):744-751. PubMed ID: 28329275 [TBL] [Abstract][Full Text] [Related]
7. Reproducibility of three different cardiac T Baeßler B; Schaarschmidt F; Stehning C; Schnackenburg B; Giolda A; Maintz D; Bunck AC J Magn Reson Imaging; 2016 Nov; 44(5):1168-1178. PubMed ID: 27043352 [TBL] [Abstract][Full Text] [Related]
8. Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS. Kvernby S; Warntjes MJ; Haraldsson H; Carlhäll CJ; Engvall J; Ebbers T J Cardiovasc Magn Reson; 2014 Dec; 16(1):102. PubMed ID: 25526880 [TBL] [Abstract][Full Text] [Related]
9. Myocardial T2 mapping reveals age- and sex-related differences in volunteers. Bönner F; Janzarik N; Jacoby C; Spieker M; Schnackenburg B; Range F; Butzbach B; Haberkorn S; Westenfeld R; Neizel-Wittke M; Flögel U; Kelm M J Cardiovasc Magn Reson; 2015 Feb; 17(1):9. PubMed ID: 25656484 [TBL] [Abstract][Full Text] [Related]
10. The Role of Improved Motion-Sensitized Driven Equilibrium Blood Suppression and Fat Saturation on T Hammood ER; Shirani S; Sadri A; Bahri M; Dehghani S J Magn Reson Imaging; 2024 Aug; 60(2):662-672. PubMed ID: 37850682 [TBL] [Abstract][Full Text] [Related]
11. T1 and T2 mapping cardiovascular magnetic resonance imaging techniques reveal unapparent myocardial injury in patients with myocarditis. Radunski UK; Lund GK; Säring D; Bohnen S; Stehning C; Schnackenburg B; Avanesov M; Tahir E; Adam G; Blankenberg S; Muellerleile K Clin Res Cardiol; 2017 Jan; 106(1):10-17. PubMed ID: 27388331 [TBL] [Abstract][Full Text] [Related]
12. Free-breathing myocardial T2* mapping using GRE-EPI and automatic non-rigid motion correction. Jin N; da Silveira JS; Jolly MP; Firmin DN; Mathew G; Lamba N; Subramanian S; Pennell DJ; Raman SV; Simonetti OP J Cardiovasc Magn Reson; 2015 Dec; 17():113. PubMed ID: 26699850 [TBL] [Abstract][Full Text] [Related]
13. Performance of t1 and t2 mapping cardiovascular magnetic resonance to detect active myocarditis in patients with recent-onset heart failure. Bohnen S; Radunski UK; Lund GK; Kandolf R; Stehning C; Schnackenburg B; Adam G; Blankenberg S; Muellerleile K Circ Cardiovasc Imaging; 2015 Jun; 8(6):. PubMed ID: 26015267 [TBL] [Abstract][Full Text] [Related]
14. A novel multiparametric imaging approach to acute myocarditis using T2-mapping and CMR feature tracking. Baeßler B; Treutlein M; Schaarschmidt F; Stehning C; Schnackenburg B; Michels G; Maintz D; Bunck AC J Cardiovasc Magn Reson; 2017 Sep; 19(1):71. PubMed ID: 28931401 [TBL] [Abstract][Full Text] [Related]
15. Variability and homogeneity of cardiovascular magnetic resonance myocardial T2-mapping in volunteers compared to patients with edema. Wassmuth R; Prothmann M; Utz W; Dieringer M; von Knobelsdorff-Brenkenhoff F; Greiser A; Schulz-Menger J J Cardiovasc Magn Reson; 2013 Mar; 15(1):27. PubMed ID: 23537111 [TBL] [Abstract][Full Text] [Related]
16. Impact of motion correction on reproducibility and spatial variability of quantitative myocardial T2 mapping. Roujol S; Basha TA; Weingärtner S; Akçakaya M; Berg S; Manning WJ; Nezafat R J Cardiovasc Magn Reson; 2015 Jun; 17(1):46. PubMed ID: 26067275 [TBL] [Abstract][Full Text] [Related]
17. Inter-scanner comparability of Z-scores for native myocardial T1 and T2 mapping. Razzaq S; Haririsanati L; Eyre K; Garg R; Chetrit M; Friedrich MG J Cardiovasc Magn Reson; 2024; 26(1):100004. PubMed ID: 38211657 [TBL] [Abstract][Full Text] [Related]
18. T2 quantification for improved detection of myocardial edema. Giri S; Chung YC; Merchant A; Mihai G; Rajagopalan S; Raman SV; Simonetti OP J Cardiovasc Magn Reson; 2009 Dec; 11(1):56. PubMed ID: 20042111 [TBL] [Abstract][Full Text] [Related]
19. Myocardial edema as detected by pre-contrast T1 and T2 CMR delineates area at risk associated with acute myocardial infarction. Ugander M; Bagi PS; Oki AJ; Chen B; Hsu LY; Aletras AH; Shah S; Greiser A; Kellman P; Arai AE JACC Cardiovasc Imaging; 2012 Jun; 5(6):596-603. PubMed ID: 22698528 [TBL] [Abstract][Full Text] [Related]
20. T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation. Hagio T; Huang C; Abidov A; Singh J; Ainapurapu B; Squire S; Bruck D; Altbach MI J Cardiovasc Magn Reson; 2015 Feb; 17(1):24. PubMed ID: 25889928 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]