  • 1. Validation of thoracic impedance cardiography by echocardiography in healthy late pregnancy.
    McIntyre JP; Ellyett KM; Mitchell EA; Quill GM; Thompson JM; Stewart AW; Doughty RN; Stone PR;
    BMC Pregnancy Childbirth; 2015 Mar; 15():70. PubMed ID: 25886289
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Agreement between preload reserve measured by impedance cardiography and echocardiography during pregnancy.
    Liang H; Vårtun Å; Acharya G
    Arch Gynecol Obstet; 2018 Jul; 298(1):59-66. PubMed ID: 29623416
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Hemodynamic evaluation in pregnancy: limitations of impedance cardiography.
    Moertl MG; Schlembach D; Papousek I; Hinghofer-Szalkay H; Weiss EM; Lang U; Lackner HK
    Physiol Meas; 2012 Jun; 33(6):1015-26. PubMed ID: 22562970
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Validation of impedance cardiography during lower body negative pressure.
    Gotshall RW; Davrath LR; Sadeh WZ; Coonts CC; Luckasen GJ; Downes TR; Tucker A
    Aviat Space Environ Med; 1999 Jan; 70(1):6-10. PubMed ID: 9895014
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Impedance cardiography in healthy children and children with congenital heart disease: Improving stroke volume assessment.
    Nederend I; Ten Harkel ADJ; Blom NA; Berntson GG; de Geus EJC
    Int J Psychophysiol; 2017 Oct; 120():136-147. PubMed ID: 28778397
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Noninvasive cardiac monitoring in pregnancy: impedance cardiography versus echocardiography.
    Burlingame J; Ohana P; Aaronoff M; Seto T
    J Perinatol; 2013 Sep; 33(9):675-80. PubMed ID: 23680787
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of impedance cardiography and cardiac magnetic resonance imaging for the evaluation of cardiac function in early-stage breast cancer patients.
    Piastopoulou E; Ali P; Bertelli G; Heatley M; Moe M; Murugesan C; Stratton G; Lewis M
    Physiol Meas; 2021 Nov; 42(10):. PubMed ID: 34547725
    [No Abstract]   [Full Text] [Related]  

  • 8. Noninvasive assessment of cardiac index in healthy volunteers: a comparison between thoracic impedance cardiography and Doppler echocardiography.
    Fellahi JL; Caille V; Charron C; Deschamps-Berger PH; Vieillard-Baron A
    Anesth Analg; 2009 May; 108(5):1553-9. PubMed ID: 19372335
    [TBL] [Abstract][Full Text] [Related]  

  • 9. A comparison between the automatized impedance cardiography and pulsed-wave Doppler echocardiography methods for measurements of stroke volume (SV) and systolic time intervals (STI).
    Cybulski G; Miśkiewicz Z; Szulc J; Torbicki A; Pasierski T
    J Physiol Pharmacol; 1993 Sep; 44(3):251-8. PubMed ID: 8241526
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Validation of stroke volume and cardiac output by electrical interrogation of the brachial artery in normals: assessment of strengths, limitations, and sources of error.
    Bernstein DP; Henry IC; Lemmens HJ; Chaltas JL; DeMaria AN; Moon JB; Kahn AM
    J Clin Monit Comput; 2015 Dec; 29(6):789-800. PubMed ID: 25682204
    [TBL] [Abstract][Full Text] [Related]  

  • 11. A hybrid approach for quantifying aortic valve stenosis using impedance cardiography and echocardiography.
    Daralammouri Y; Ayoub K; Badrieh N; Lauer B
    BMC Cardiovasc Disord; 2016 Jan; 16():19. PubMed ID: 26800673
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Comparison of maternal third trimester hemodynamics between singleton pregnancy and twin pregnancy.
    Sima RM; Findeklee S; Bădărău IA; Poenaru MO; Scheau C; Pleș L
    J Perinat Med; 2021 Jun; 49(5):566-571. PubMed ID: 33567181
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Interrater reliability and parallel forms reliability of two noninvasive hemodynamic monitoring devices in clinically stable emergency department patients.
    Napoli AM; Machan JT; Corl K; Forcada A
    Eur J Emerg Med; 2012 Oct; 19(5):297-303. PubMed ID: 22008590
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Beat-to-beat estimation of stroke volume using impedance cardiography and artificial neural network.
    Naidu SMM; Pandey PC; Bagal UR; Hardas SP
    Med Biol Eng Comput; 2018 Jun; 56(6):1077-1089. PubMed ID: 29150800
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Stroke volume and systolic time intervals: beat-to-beat comparison between echocardiography and ambulatory impedance cardiography in supine and tilted positions.
    Cybulski G; Michalak E; Koźluk E; Piatkowska A; Niewiadomski W
    Med Biol Eng Comput; 2004 Sep; 42(5):707-11. PubMed ID: 15503973
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Comparison of stroke volume measurements during hemodialysis using bioimpedance cardiography and echocardiography.
    Germain MJ; Joubert J; O'Grady D; Nathanson BH; Chait Y; Levin NW
    Hemodial Int; 2018 Apr; 22(2):201-208. PubMed ID: 28796425
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transthoracic impedance cardiography: a noninvasive method of hemodynamic assessment.
    Bayram M; Yancy CW
    Heart Fail Clin; 2009 Apr; 5(2):161-8. PubMed ID: 19249685
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Reliability of Peak Exercise Stroke Volume Assessment by Impedance Cardiography in Patients with Residual Right Outflow Tract Lesions After Congenital Heart Disease Repair.
    Legendre A; Bonnet D; Bosquet L
    Pediatr Cardiol; 2018 Jan; 39(1):45-50. PubMed ID: 28948370
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Measuring Stroke Volume: Impedance Cardiography vs Phase-Contrast Magnetic Resonance Imaging.
    Borzage M; Heidari K; Chavez T; Seri I; Wood JC; Blüml S
    Am J Crit Care; 2017 Sep; 26(5):408-415. PubMed ID: 28864438
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The non-invasive assessment of stroke volume and cardiac output by impedance cardiography: a review.
    Newman DG; Callister R
    Aviat Space Environ Med; 1999 Aug; 70(8):780-9. PubMed ID: 10447052
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.