These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

143 related articles for article (PubMed ID: 25886289)

  • 21. Holter-type impedance cardiography device. A system for continuous and non-invasive monitoring of cardiac haemodynamics.
    Cybulski G; Koźluk E; Michalak E; Niewiadomski W; Piatkowska A
    Kardiol Pol; 2004 Aug; 61(8):138-46. PubMed ID: 15457280
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Signal-morphology impedance cardiography during incremental cardiopulmonary exercise testing in pulmonary arterial hypertension.
    Ferreira EM; Ota-Arakaki JS; Barbosa PB; Siqueira AC; Bravo DM; Kapins CE; Silva CM; Nery LE; Neder JA
    Clin Physiol Funct Imaging; 2012 Sep; 32(5):343-52. PubMed ID: 22856340
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Impedance cardiography for monitoring changes in cardiac output.
    Parashar R; Bajpai M; Goyal M; Singh S; Tiwari S; Narayan VS
    Indian J Physiol Pharmacol; 2012; 56(2):117-24. PubMed ID: 23387239
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Comparison of electrical velocimetry and transoesophageal Doppler echocardiography for measuring stroke volume and cardiac output.
    Schmidt C; Theilmeier G; Van Aken H; Korsmeier P; Wirtz SP; Berendes E; Hoffmeier A; Meissner A
    Br J Anaesth; 2005 Nov; 95(5):603-10. PubMed ID: 16155037
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Comparison of electrical velocimetry and cardiac magnetic resonance imaging for the non-invasive determination of cardiac output.
    Trinkmann F; Berger M; Doesch C; Papavassiliu T; Schoenberg SO; Borggrefe M; Kaden JJ; Saur J
    J Clin Monit Comput; 2016 Aug; 30(4):399-408. PubMed ID: 26115774
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Computer method for automatic determination of stroke volume using impedance cardiography signals.
    Cybulski G
    Acta Physiol Pol; 1988; 39(5-6):494-503. PubMed ID: 3257063
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Impedance cardiography (electrical velocimetry) and transthoracic echocardiography for non-invasive cardiac output monitoring in pediatric intensive care patients: a prospective single-center observational study.
    Blohm ME; Obrecht D; Hartwich J; Mueller GC; Kersten JF; Weil J; Singer D
    Crit Care; 2014 Nov; 18(6):603. PubMed ID: 25407329
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Measurement of cardiac stroke volume by impedance cardiography in the last trimester of pregnancy.
    Milsom I; Forssman L; Sivertsson R; Dottori O
    Acta Obstet Gynecol Scand; 1983; 62(5):473-9. PubMed ID: 6364687
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A validation study of electrical cardiometry in pregnant patients using transthoracic echocardiography as the reference standard.
    Martin E; Anyikam A; Ballas J; Buono K; Mantell K; Huynh-Covey T; Archer T
    J Clin Monit Comput; 2016 Oct; 30(5):679-86. PubMed ID: 26403606
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Stroke volume equation for impedance cardiography.
    Bernstein DP; Lemmens HJ
    Med Biol Eng Comput; 2005 Jul; 43(4):443-50. PubMed ID: 16255425
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stroke volume and cardiac output measurement in cardiac patients during a rehabilitation program: comparison between tonometry, impedancemetry and echocardiography.
    Gonzalez-Represas A; Mourot L
    Int J Cardiovasc Imaging; 2020 Mar; 36(3):447-455. PubMed ID: 31845049
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Clinical evaluation of an ensemble-averaging impedance cardiograph for monitoring stroke volume during spontaneous breathing.
    Ekman LG; Milsom I; Arvidsson S; Biber B; Martinell S; Sjöqvist BA
    Acta Anaesthesiol Scand; 1990 Apr; 34(3):190-6. PubMed ID: 1693029
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Assessment of cardiac time intervals by wavelet transform of the impedance cardiogram.
    Stepanov R; Podtaev S; Dumler A; Chugainov S
    Technol Health Care; 2016 Apr; 24 Suppl 2():S803-9. PubMed ID: 27259086
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Utility of impedance cardiography to improve physician estimation of hemodynamic parameters in the emergency department.
    Neath SX; Lazio L; Guss DA
    Congest Heart Fail; 2005; 11(1):17-20. PubMed ID: 15722666
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Good agreement between echocardiography and impedance cardiography in the assessment of left ventricular performance in hypertensive patients.
    Nazário Leão R; Silva PMD; Pocinho RM; Alves M; Virella D; Palma Reis R
    Clin Exp Hypertens; 2018; 40(5):461-467. PubMed ID: 29172784
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Accuracy of Impedance Cardiography for Hemodynamic Assessment During Rest and Exercise in Wheelchair Rugby Players.
    Małek ŁA; Mróz A; Czajkowska A; Kosmol A; Ogonowska-Słodownik A; Molik B; Morgulec-Adamowicz N
    Res Q Exerc Sport; 2019 Sep; 90(3):336-343. PubMed ID: 31082312
    [No Abstract]   [Full Text] [Related]  

  • 37. Improvement of Left Ventricular Ejection Time Measurement in the Impedance Cardiography Combined with the Reflection Photoplethysmography.
    Liu SH; Wang JJ; Su CH; Cheng DC
    Sensors (Basel); 2018 Sep; 18(9):. PubMed ID: 30208616
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Therapeutic optimization of atrioventricular delay in cardiosurgical ICU patients by noninvasive cardiac output measurements versus pulse contour analysis.
    Mellert F; Lindner P; Schiller W; Gersing E; Heinze I; Kreuz J; Welz A; Preusse CJ
    Thorac Cardiovasc Surg; 2008 Aug; 56(5):269-73. PubMed ID: 18615372
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Impedance cardiography: the failure of sternal electrodes to predict changes in stroke volume.
    Patterson R; Wang L; McVeigh G; Burns R; Cohn J
    Biol Psychol; 1993 Aug; 36(1-2):33-41. PubMed ID: 8218622
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Impedance cardiography in uncomplicated pregnancy and pre-eclampsia: a reliability study.
    Tomsin K; Mesens T; Molenberghs G; Gyselaers W
    J Obstet Gynaecol; 2012 Oct; 32(7):630-4. PubMed ID: 22943706
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.