BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

184 related articles for article (PubMed ID: 25889928)

  • 1. T2 mapping of the heart with a double-inversion radial fast spin-echo method with indirect echo compensation.
    Hagio T; Huang C; Abidov A; Singh J; Ainapurapu B; Squire S; Bruck D; Altbach MI
    J Cardiovasc Magn Reson; 2015 Feb; 17(1):24. PubMed ID: 25889928
    [TBL] [Abstract][Full Text] [Related]  

  • 2. A multi-band double-inversion radial fast spin-echo technique for T2 cardiovascular magnetic resonance mapping of the heart.
    Keerthivasan MB; Mandava S; Johnson K; Avery R; Janardhanan R; Martin DR; Bilgin A; Altbach MI
    J Cardiovasc Magn Reson; 2018 Jul; 20(1):49. PubMed ID: 30025523
    [TBL] [Abstract][Full Text] [Related]  

  • 3. T2 relaxometry with indirect echo compensation from highly undersampled data.
    Huang C; Bilgin A; Barr T; Altbach MI
    Magn Reson Med; 2013 Oct; 70(4):1026-37. PubMed ID: 23165796
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Pattern recognition for rapid T2 mapping with stimulated echo compensation.
    Huang C; Altbach MI; El Fakhri G
    Magn Reson Imaging; 2014 Sep; 32(7):969-74. PubMed ID: 24853466
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gradient Spin Echo (GraSE) imaging for fast myocardial T2 mapping.
    Sprinkart AM; Luetkens JA; Träber F; Doerner J; Gieseke J; Schnackenburg B; Schmitz G; Thomas D; Homsi R; Block W; Schild H; Naehle CP
    J Cardiovasc Magn Reson; 2015 Feb; 17(1):12. PubMed ID: 25885268
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Fast T2 mapping with improved accuracy using undersampled spin-echo MRI and model-based reconstructions with a generating function.
    Sumpf TJ; Petrovic A; Uecker M; Knoll F; Frahm J
    IEEE Trans Med Imaging; 2014 Dec; 33(12):2213-22. PubMed ID: 24988592
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Limitations of skipping echoes for exponential T
    McPhee KC; Wilman AH
    J Magn Reson Imaging; 2018 Nov; 48(5):1432-1440. PubMed ID: 29687931
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Fast and High-Resolution T
    Li H; Priest AN; Horvat-Menih I; Huang Y; Li S; Stewart GD; Mendichovszky IA; Francis ST; Gallagher FA
    Magn Reson Med; 2024 Sep; 92(3):1138-1148. PubMed ID: 38730565
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Rapid high-resolution T
    Li Z; Bilgin A; Johnson K; Galons JP; Vedantham S; Martin DR; Altbach MI
    J Magn Reson Imaging; 2019 Jan; 49(1):239-252. PubMed ID: 30142230
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Fast model-based T
    Hilbert T; Schulz J; Marques JP; Thiran JP; Krueger G; Norris DG; Kober T
    Magn Reson Med; 2019 Dec; 82(6):2090-2103. PubMed ID: 31273830
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accelerated free-breathing whole-heart 3D T
    Bustin A; Milotta G; Ismail TF; Neji R; Botnar RM; Prieto C
    Magn Reson Med; 2020 Mar; 83(3):988-1002. PubMed ID: 31535729
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reverse double inversion-recovery: Improving motion robustness of cardiac T
    Hu C; Huber S; Latif SR; Santacana-Laffitte G; Mojibian HR; Baldassarre LA; Peters DC
    J Magn Reson Imaging; 2018 Jun; 47(6):1498-1508. PubMed ID: 29112315
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Model-based nonlinear inverse reconstruction for T2 mapping using highly undersampled spin-echo MRI.
    Sumpf TJ; Uecker M; Boretius S; Frahm J
    J Magn Reson Imaging; 2011 Aug; 34(2):420-8. PubMed ID: 21780234
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Effect of echo spacing and readout bandwidth on basic performances of EPI-fMRI acquisition sequences implemented on two 1.5 T MR scanner systems.
    Giannelli M; Diciotti S; Tessa C; Mascalchi M
    Med Phys; 2010 Jan; 37(1):303-10. PubMed ID: 20175493
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Free-running simultaneous myocardial T1/T2 mapping and cine imaging with 3D whole-heart coverage and isotropic spatial resolution.
    Qi H; Bustin A; Cruz G; Jaubert O; Chen H; Botnar RM; Prieto C
    Magn Reson Imaging; 2019 Nov; 63():159-169. PubMed ID: 31425810
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Model-based super-resolution reconstruction of T
    Bano W; Piredda GF; Davies M; Marshall I; Golbabaee M; Meuli R; Kober T; Thiran JP; Hilbert T
    Magn Reson Med; 2020 Mar; 83(3):906-919. PubMed ID: 31517404
    [TBL] [Abstract][Full Text] [Related]  

  • 17. T
    Snyder J; McPhee KC; Wilman AH
    Magn Reson Med; 2022 May; 87(5):2145-2160. PubMed ID: 34894641
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Simultaneous three-dimensional myocardial T1 and T2 mapping in one breath hold with 3D-QALAS.
    Kvernby S; Warntjes MJ; Haraldsson H; Carlhäll CJ; Engvall J; Ebbers T
    J Cardiovasc Magn Reson; 2014 Dec; 16(1):102. PubMed ID: 25526880
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Three-dimensional T1 and T2* mapping of human lung parenchyma using interleaved saturation recovery with dual echo ultrashort echo time imaging (ITSR-DUTE).
    Gai ND; Malayeri AA; Bluemke DA
    J Magn Reson Imaging; 2017 Apr; 45(4):1097-1104. PubMed ID: 27726231
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement reproducibility of slice-interleaved T1 and T2 mapping sequences over 20 months: A single center study.
    Jang J; Ngo LH; Captur G; Moon JC; Nezafat R
    PLoS One; 2019; 14(7):e0220190. PubMed ID: 31344078
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.