254 related articles for article (PubMed ID: 25902305)
21. Evaluation of platelet function in essential thrombocythemia under different analytical conditions.
Lussana F; Femia EA; Pugliano M; Podda G; Razzari C; Maugeri N; Lecchi A; Caberlon S; Gerli G; Cattaneo M
Platelets; 2020; 31(2):179-186. PubMed ID: 30892978
[No Abstract] [Full Text] [Related]
22. Effects of donor characteristics and platelet in vitro time and temperature on platelet aggregometry.
Silver WP; Keller MP; Teel R; Silver D
J Vasc Surg; 1993 Apr; 17(4):726-33. PubMed ID: 8464092
[TBL] [Abstract][Full Text] [Related]
23. The influence of low platelet count on whole blood aggregometry assessed by Multiplate.
Stissing T; Dridi NP; Ostrowski SR; Bochsen L; Johansson PI
Clin Appl Thromb Hemost; 2011; 17(6):E211-7. PubMed ID: 21406416
[TBL] [Abstract][Full Text] [Related]
24. [Platelet aggregability in apparently healthy humans of different ages].
Kirichuk VF; Voskoboĭ IV
Fiziol Cheloveka; 2006; 32(4):116-20. PubMed ID: 16910082
[No Abstract] [Full Text] [Related]
25. More on preanalytical variables affecting platelet function testing using light transmittance aggregometry.
Favaloro EJ
Clin Chem Lab Med; 2011 Apr; 49(4):737-9. PubMed ID: 21275810
[No Abstract] [Full Text] [Related]
26. [Adjusting Platelet Counts for Platelet Aggregation Tests].
Ling LQ; Yang XC; Chen H; Liu CN; Chen S; Jiang H; Jin YX; Zhou J
Sichuan Da Xue Xue Bao Yi Xue Ban; 2018 Mar; 49(2):276-279. PubMed ID: 29737075
[TBL] [Abstract][Full Text] [Related]
27. Whole blood platelet aggregation in humans and animals: a comparative study.
Soloviev MV; Okazaki Y; Harasaki H
J Surg Res; 1999 Apr; 82(2):180-7. PubMed ID: 10090827
[TBL] [Abstract][Full Text] [Related]
28. The effect of pre-analytical variables on light transmittance aggregometry in citrated platelet-rich plasma from healthy subjects.
Stegnar M; Knezevic A; Bozic-Mijovski M
Clin Chem Lab Med; 2010 Oct; 48(10):1463-5. PubMed ID: 20618093
[TBL] [Abstract][Full Text] [Related]
29. Evaluation of platelet function, a method comparison.
Nylander S; Johansson K; Van Giezen JJ; Lindahl TL
Platelets; 2006 Feb; 17(1):49-55. PubMed ID: 16308187
[TBL] [Abstract][Full Text] [Related]
30. Effects of omega-3 polyunsaturated fatty acids on platelet function in healthy subjects and subjects with cardiovascular disease.
McEwen BJ; Morel-Kopp MC; Chen W; Tofler GH; Ward CM
Semin Thromb Hemost; 2013 Feb; 39(1):25-32. PubMed ID: 23329646
[TBL] [Abstract][Full Text] [Related]
31. To adjust or not to adjust the platelet count in light transmission aggregometry in patients receiving dual aspirin/clopidogrel treatment.
van der Stelt CA; van Werkum JW; Seesing TH; Berg JM; Hackeng CM
Platelets; 2007 Nov; 18(7):550-3. PubMed ID: 17957573
[TBL] [Abstract][Full Text] [Related]
32. Influence of storage temperature on the responsiveness of human platelets to agonists.
Choi JW; Pai SH
Ann Clin Lab Sci; 2003; 33(1):79-85. PubMed ID: 12661901
[TBL] [Abstract][Full Text] [Related]
33. Evaluation of the platelet count drop method for assessment of platelet function in comparison with "gold standard" light transmission aggregometry.
Lordkipanidzé M; Pharand C; Schampaert E; Palisaitis DA; Diodati JG
Thromb Res; 2009 Sep; 124(4):418-22. PubMed ID: 19250657
[TBL] [Abstract][Full Text] [Related]
34. Measurement of platelet function in dogs using a novel impedance aggregometer.
Kalbantner K; Baumgarten A; Mischke R
Vet J; 2010 Aug; 185(2):144-51. PubMed ID: 19879171
[TBL] [Abstract][Full Text] [Related]
35. In vitro effect of sodium nitrite on platelet aggregation in human platelet rich plasma--preliminary report.
Kadan M; Doğanci S; Yildirim V; Özgür G; Erol G; Karabacak K; Avcu F
Eur Rev Med Pharmacol Sci; 2015 Oct; 19(20):3935-9. PubMed ID: 26531282
[TBL] [Abstract][Full Text] [Related]
36. Does the magnetic field of a magnetic stirrer in an optical aggregometer affect concurrent platelet aggregation?
Sagdilek E; Sebik O; Celebi G
Bioelectromagnetics; 2013 Jul; 34(5):349-57. PubMed ID: 23436227
[TBL] [Abstract][Full Text] [Related]
37. Improvement of bleeding time, platelet aggregation and platelet count during CAPD treatment.
Arends JP; Krediet RT; Boeschoten EW; van der Lelie J; Veenhof CH; von dem Borne AE
Proc Eur Dial Transplant Assoc; 1981; 18():280-5. PubMed ID: 7329972
[TBL] [Abstract][Full Text] [Related]
38. Platelet aggregation testing in platelet-rich plasma: description of procedures with the aim to develop standards in the field.
Zhou L; Schmaier AH
Am J Clin Pathol; 2005 Feb; 123(2):172-83. PubMed ID: 15842039
[TBL] [Abstract][Full Text] [Related]
39. Comparison of VASP-phosphorylation assay to light-transmission aggregometry in assessing inhibition of the platelet ADP P2Y12 receptor.
Pampuch A; Cerletti C; de Gaetano G
Thromb Haemost; 2006 Dec; 96(6):767-73. PubMed ID: 17139371
[TBL] [Abstract][Full Text] [Related]
40. Comparison of haemostatic function of PAS-C-platelets vs. plasma-platelets in reconstituted whole blood using impedance aggregometry and thromboelastography.
van Hout FMA; Bontekoe IJ; de Laleijne LAE; Kerkhoffs JL; de Korte D; Eikenboom J; van der Bom JG; van der Meer PF
Vox Sang; 2017 Aug; 112(6):549-556. PubMed ID: 28597485
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]