BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

471 related articles for article (PubMed ID: 25903714)

  • 1. A novel technique for CT-guided transthoracic biopsy of lung lesions: improved biopsy accuracy and safety.
    Yaffe D; Koslow M; Haskiya H; Shitrit D
    Eur Radiol; 2015 Nov; 25(11):3354-60. PubMed ID: 25903714
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transthoracic CT-guided biopsy with multiplanar reconstruction image improves diagnostic accuracy of solitary pulmonary nodules.
    Ohno Y; Hatabu H; Takenaka D; Imai M; Ohbayashi C; Sugimura K
    Eur J Radiol; 2004 Aug; 51(2):160-8. PubMed ID: 15246522
    [TBL] [Abstract][Full Text] [Related]  

  • 3. CT-guided transthoracic needle aspiration biopsy of subsolid lung lesions.
    Maxwell AW; Klein JS; Dantey K; Mount SL; Butnor KJ; Leiman G
    J Vasc Interv Radiol; 2014 Mar; 25(3):340-6, 346.e1. PubMed ID: 24581458
    [TBL] [Abstract][Full Text] [Related]  

  • 4. CT-guided transthoracic needle aspiration biopsy of pulmonary nodules: needle size and pneumothorax rate.
    Geraghty PR; Kee ST; McFarlane G; Razavi MK; Sze DY; Dake MD
    Radiology; 2003 Nov; 229(2):475-81. PubMed ID: 14595149
    [TBL] [Abstract][Full Text] [Related]  

  • 5. CT-guided transthoracic needle biopsy of pulmonary lesions: comparison between the cutting needle and aspiration needle.
    Huang ZG; Sun HL; Wang CL; Gao BX; Chen H; Yang MX; Chen XL
    Br J Radiol; 2021 Feb; 94(1118):20190930. PubMed ID: 33245675
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Feasibility and accuracy of CT-guided percutaneous needle biopsy of cavitary pulmonary lesions.
    Kiranantawat N; Petranović M; McDermott S; Gilman M; Digumarthy SR; Shepard JO; Sharma A
    Diagn Interv Radiol; 2019 Nov; 25(6):435-441. PubMed ID: 31650972
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Diagnostic accuracy and safety of CT-guided fine needle aspiration biopsy of pulmonary lesions with non-coaxial technique: a single center experience with 442 biopsies.
    Uzun Ç; Akkaya Z; Düşünceli Atman E; Üstüner E; Peker E; Gülpınar B; Elhan AH; Ceyhan K; Atasoy KÇ
    Diagn Interv Radiol; 2017; 23(2):137-143. PubMed ID: 28029638
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Intrapulmonary lesions: percutaneous automated biopsy with a detachable, 18-gauge, coaxial cutting needle.
    Lucidarme O; Howarth N; Finet JF; Grenier PA
    Radiology; 1998 Jun; 207(3):759-65. PubMed ID: 9609901
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Coaxial technique-promoted diagnostic accuracy of CT-guided percutaneous cutting needle biopsy for small and deep lung lesions.
    Zhang L; Shi L; Xiao Z; Qiu H; Peng P; Zhang M
    PLoS One; 2018; 13(2):e0192920. PubMed ID: 29447239
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CT-guided transthoracic needle biopsy of pulmonary nodules smaller than 20 mm: results with an automated 20-gauge coaxial cutting needle.
    Laurent F; Latrabe V; Vergier B; Montaudon M; Vernejoux JM; Dubrez J
    Clin Radiol; 2000 Apr; 55(4):281-7. PubMed ID: 10767187
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung.
    Kazerooni EA; Lim FT; Mikhail A; Martinez FJ
    Radiology; 1996 Feb; 198(2):371-5. PubMed ID: 8596834
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Learning Curve for CT-Guided Percutaneous Transthoracic Needle Biopsy: Retrospective Evaluation Among 17 Thoracic Imaging Fellows at a Tertiary Referral Hospital.
    Park R; Lee SM; Kim S; Park S; Choe J; Do KH; Seo JB
    AJR Am J Roentgenol; 2022 Jan; 218(1):112-123. PubMed ID: 34406052
    [No Abstract]   [Full Text] [Related]  

  • 13. CT-guided cutting needle biopsy of lung lesions--safety and efficacy of an out-patient service.
    Charig MJ; Phillips AJ
    Clin Radiol; 2000 Dec; 55(12):964-9. PubMed ID: 11124077
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Pneumothorax with prolonged chest tube requirement after CT-guided percutaneous lung biopsy: incidence and risk factors.
    Moreland A; Novogrodsky E; Brody L; Durack J; Erinjeri J; Getrajdman G; Solomon S; Yarmohammadi H; Maybody M
    Eur Radiol; 2016 Oct; 26(10):3483-91. PubMed ID: 26787605
    [TBL] [Abstract][Full Text] [Related]  

  • 15. CT-guided transthoracic needle biopsy using a puncture site-down positioning technique.
    Kinoshita F; Kato T; Sugiura K; Nishimura M; Kinoshita T; Hashimoto M; Kaminoh T; Ogawa T
    AJR Am J Roentgenol; 2006 Oct; 187(4):926-32. PubMed ID: 16985136
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Efficacy of the tract embolization technique with gelatin sponge slurry to reduce pneumothorax and chest tube placement after percutaneous CT-guided lung biopsy.
    Renier H; Gérard L; Lamborelle P; Cousin F
    Cardiovasc Intervent Radiol; 2020 Apr; 43(4):597-603. PubMed ID: 31792589
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Pneumothoraces and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors.
    Laurent F; Michel P; Latrabe V; Tunon de Lara M; Marthan R
    AJR Am J Roentgenol; 1999 Apr; 172(4):1049-53. PubMed ID: 10587145
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Diagnosis of peripheral pulmonary lesions using endobronchial ultrasonography with a guide sheath and computed tomography guided transthoracic needle aspiration.
    Zhu J; Gu Y
    Clin Respir J; 2019 Dec; 13(12):765-772. PubMed ID: 31487103
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Extra-pleuric coaxial system for CT-guided percutaneous fine-needle aspiration biopsy (FNAB) of small (≤20 mm) lung nodules: a novel technique using multiplanar reconstruction (MPR) images.
    Capasso R; Nizzoli R; Tiseo M; Pedrazzi G; Brunese L; Rotondo A; De Filippo M
    Med Oncol; 2017 Feb; 34(2):17. PubMed ID: 28035579
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Accuracy and complications in computed tomography fluoroscopy-guided needle biopsies of lung masses.
    Heck SL; Blom P; Berstad A
    Eur Radiol; 2006 Jun; 16(6):1387-92. PubMed ID: 16541227
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 24.