These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
1136 related articles for article (PubMed ID: 25903943)
1. Wear and Osteolysis of Highly Crosslinked Polyethylene at 10 to 14 Years: The Effect of Femoral Head Size. Lachiewicz PF; Soileau ES; Martell JM Clin Orthop Relat Res; 2016 Feb; 474(2):365-71. PubMed ID: 25903943 [TBL] [Abstract][Full Text] [Related]
2. Large Metal Heads and Highly Cross-Linked Polyethylene Provide Low Wear and Complications at 5-13 Years. Lachiewicz PF; O'Dell JA; Martell JM J Arthroplasty; 2018 Jul; 33(7):2187-2191. PubMed ID: 29588121 [TBL] [Abstract][Full Text] [Related]
3. Oxidized zirconium head on crosslinked polyethylene liner in total hip arthroplasty: a 7- to 12-year in vivo comparative wear study. Karidakis GK; Karachalios T Clin Orthop Relat Res; 2015 Dec; 473(12):3836-45. PubMed ID: 26290343 [TBL] [Abstract][Full Text] [Related]
4. Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years. Garvin KL; White TC; Dusad A; Hartman CW; Martell J Clin Orthop Relat Res; 2015 Dec; 473(12):3829-35. PubMed ID: 26122983 [TBL] [Abstract][Full Text] [Related]
5. Otto Aufranc Award: Crosslinking Reduces THA Wear, Osteolysis, and Revision Rates at 15-year Followup Compared With Noncrosslinked Polyethylene. Hopper RH; Ho H; Sritulanondha S; Williams AC; Engh CA Clin Orthop Relat Res; 2018 Feb; 476(2):279-290. PubMed ID: 29529656 [TBL] [Abstract][Full Text] [Related]
6. Femoral head size and wear of highly cross-linked polyethylene at 5 to 8 years. Lachiewicz PF; Heckman DS; Soileau ES; Mangla J; Martell JM Clin Orthop Relat Res; 2009 Dec; 467(12):3290-6. PubMed ID: 19690932 [TBL] [Abstract][Full Text] [Related]
7. Ceramic-on-ceramic THA associated with fewer dislocations and less muscle degeneration by preserving muscle progenitors. Hernigou P; Roussignol X; Delambre J; Poignard A; Flouzat-Lachaniette CH Clin Orthop Relat Res; 2015 Dec; 473(12):3762-9. PubMed ID: 26054482 [TBL] [Abstract][Full Text] [Related]
8. Ceramic femoral head in highly cross-linked polyethylene cup. 5 year results of a randomized trial. Peker G; Bala MM; Altun I Ann Ital Chir; 2022; 93():202-209. PubMed ID: 35321960 [TBL] [Abstract][Full Text] [Related]
9. [Comparative study on association between femoral head size and linear wear rate of highly cross-linked polyethylene liner]. Guo S; Sun J; Zha G; Wei S; Lu Q Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2014 Nov; 28(11):1333-7. PubMed ID: 25639045 [TBL] [Abstract][Full Text] [Related]
10. Ten-year follow-up study of three alternative bearing surfaces used in total hip arthroplasty in young patients: a prospective randomised controlled trial. Atrey A; Ward SE; Khoshbin A; Hussain N; Bogoch E; Schemitsch EH; Waddell JP Bone Joint J; 2017 Dec; 99-B(12):1590-1595. PubMed ID: 29212681 [TBL] [Abstract][Full Text] [Related]
11. Polyethylene Liner and Femoral Head Exchange in Total Hip Arthroplasty: Factors Associated with Long-Term Success and Failure. Petis SM; Kubista B; Hartzler RU; Abdel MP; Berry DJ J Bone Joint Surg Am; 2019 Mar; 101(5):421-428. PubMed ID: 30845036 [TBL] [Abstract][Full Text] [Related]
13. Differences in Femoral Head Penetration Between Highly Cross-Linked Polyethylene Cemented Sockets and Uncemented Liners. Morita D; Seki T; Higuchi Y; Takegami Y; Ishiguro N J Arthroplasty; 2017 Dec; 32(12):3796-3801. PubMed ID: 28781017 [TBL] [Abstract][Full Text] [Related]
14. Ceramic-on-ceramic THA Implants in Patients Younger Than 20 Years. Hannouche D; Devriese F; Delambre J; Zadegan F; Tourabaly I; Sedel L; Chevret S; Nizard R Clin Orthop Relat Res; 2016 Feb; 474(2):520-7. PubMed ID: 26341897 [TBL] [Abstract][Full Text] [Related]
15. [Comparative study on high cross-linked and traditional polyethylene cup liners in total hip arthroplasty]. Wei Z; Sun J; Zha G; Dong S; Wang T; Fany Y Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2013 Dec; 27(12):1414-8. PubMed ID: 24640355 [TBL] [Abstract][Full Text] [Related]
16. Is There a Difference in Revision Risk Between Metal and Ceramic Heads on Highly Crosslinked Polyethylene Liners? Cafri G; Paxton EW; Love R; Bini SA; Kurtz SM Clin Orthop Relat Res; 2017 May; 475(5):1349-1355. PubMed ID: 27385222 [TBL] [Abstract][Full Text] [Related]
17. Primary ceramic-on-ceramic total hip arthroplasty using a 32-mm ceramic head with a titanium-alloy sleeve. Lim SJ; Jang SP; Kim DW; Moon YW; Park YS Clin Orthop Relat Res; 2015 Dec; 473(12):3781-7. PubMed ID: 26024582 [TBL] [Abstract][Full Text] [Related]
18. Frequent femoral neck osteolysis with Birmingham mid-head resection resurfacing arthroplasty in young patients. Asaad A; Hart A; Khoo MM; Ilo K; Schaller G; Black JD; Muirhead-Allwood S Clin Orthop Relat Res; 2015 Dec; 473(12):3770-8. PubMed ID: 25981716 [TBL] [Abstract][Full Text] [Related]
19. The 2012 John Charnley Award: Clinical multicenter studies of the wear performance of highly crosslinked remelted polyethylene in THA. Bragdon CR; Doerner M; Martell J; Jarrett B; Palm H; ; Malchau H Clin Orthop Relat Res; 2013 Feb; 471(2):393-402. PubMed ID: 23070661 [TBL] [Abstract][Full Text] [Related]
20. Relationship between polyethylene wear and osteolysis in hips with a second-generation porous-coated cementless cup after seven years of follow-up. Orishimo KF; Claus AM; Sychterz CJ; Engh CA J Bone Joint Surg Am; 2003 Jun; 85(6):1095-9. PubMed ID: 12784009 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]