These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

132 related articles for article (PubMed ID: 25906945)

  • 21. Fracture of ceramic heads in total hip replacement.
    Habermann B; Ewald W; Rauschmann M; Zichner L; Kurth AA
    Arch Orthop Trauma Surg; 2006 Sep; 126(7):464-70. PubMed ID: 16810547
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Mixing of Head-Stem Components in Total Hip Arthroplasty.
    Mueller U; Panzram B; Braun S; Sonntag R; Kretzer JP
    J Arthroplasty; 2018 Mar; 33(3):945-951. PubMed ID: 29174405
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions.
    Al-Hajjar M; Fisher J; Tipper JL; Williams S; Jennings LM
    Proc Inst Mech Eng H; 2013 May; 227(5):535-42. PubMed ID: 23637263
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [A comparative study of the characteristics of femoral hip prosthesis heads--study and results ceramic-coated hip joint heads of titanium].
    Hennig FF; von Kroge H; Repenning D
    Biomed Tech (Berl); 1992 Sep; 37(9):200-4. PubMed ID: 1391607
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Influence of the compliance of a patient's body on the head taper fixation strength of modular hip implants.
    Krull A; Bishop NE; Steffen NM; Lampe F; Püschel K; Morlock MM
    Clin Biomech (Bristol, Avon); 2017 Jul; 46():1-5. PubMed ID: 28463695
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Serum-cobalt levels with metal-on-metal bearings in the cement-free total hip arthroplasty results covering two years; prospective study.
    Weissinger M; Grübl A; Pöll G
    Acta Chir Orthop Traumatol Cech; 2011; 78(5):410-5. PubMed ID: 22094154
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Incidence of Modern Alumina Ceramic and Alumina Matrix Composite Femoral Head Failures in Nearly 6 Million Hip Implants.
    Lee GC; Kim RH
    J Arthroplasty; 2017 Feb; 32(2):546-551. PubMed ID: 27623429
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Mechanical and numerical characterization of ceramic femoral components for hip resurfacing arthroplasty.
    Vogel D; Liebelt M; Kalkowsky F; Oberbach T; Delfosse D; Bader R
    Proc Inst Mech Eng H; 2019 Sep; 233(9):883-891. PubMed ID: 31210590
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A case-driven hypothesis for multi-stage crack growth mechanism in fourth-generation ceramic head fracture.
    Lucchini S; Baleani M; Giardina F; Martelli A; Castagnini F; Bordini B; Traina F
    J Orthop Surg Res; 2022 Jun; 17(1):293. PubMed ID: 35658905
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Choosing a Femoral Head: A Survey Study of Academic Adult Reconstructive Surgeons.
    Nandi S; Austin MS
    J Arthroplasty; 2017 May; 32(5):1530-1534. PubMed ID: 28065626
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Stress analysis of hemispherical ceramic hip prosthesis bearings.
    Anderson IA; Bowden M; Wyatt TP
    Med Eng Phys; 2005 Mar; 27(2):115-22. PubMed ID: 15642507
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Influence of Assembly Force and Distraction on the Femoral Head-Taper Junction.
    Grosso MJ; Jang ES; Longaray J; Buell S; Alfonso E; Shah RP
    J Arthroplasty; 2018 Jul; 33(7S):S275-S279. PubMed ID: 29530520
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Alternative materials to improve total hip replacement tribology.
    Santavirta S; Böhler M; Harris WH; Konttinen YT; Lappalainen R; Muratoglu O; Rieker C; Salzer M
    Acta Orthop Scand; 2003 Aug; 74(4):380-8. PubMed ID: 14521286
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Modular sleeves with ceramic heads in isolated acetabular cup revision in younger patients-laboratory and experimental analysis of suitability and clinical outcomes.
    Helwig P; Konstantinidis L; Hirschmüller A; Bernstein A; Hauschild O; Südkamp NP; Ochs BG
    Int Orthop; 2013 Jan; 37(1):15-9. PubMed ID: 23223972
    [TBL] [Abstract][Full Text] [Related]  

  • 35. [Abrasion reducing polyethylene ceramic-metal compound hip prosthesis head].
    Hennig FF; Repenning D
    Unfallchirurg; 1995 Oct; 98(10):526-9. PubMed ID: 7502087
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Ceramic-on-ceramic bearings in total hip arthroplasty (THA)].
    Sentürk U; Perka C
    Z Orthop Unfall; 2015 Apr; 153(2):198-202. PubMed ID: 25874400
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Ceramic-on-ceramic failure secondary to head-neck taper mismatch.
    Hohman DW; Affonso J; Anders M
    Am J Orthop (Belle Mead NJ); 2011 Nov; 40(11):571-3. PubMed ID: 22263210
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Pre-clinical evaluation of ceramic femoral head resurfacing prostheses using computational models and mechanical testing.
    Dickinson AS; Browne M; Wilson KC; Leffers JR; Taylor AC
    Proc Inst Mech Eng H; 2011 Sep; 225(9):866-76. PubMed ID: 22070024
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Delayed catastrophic failure of a ceramic head in hybrid total hip arthroplasty.
    Anwar I; Bhatnagar G; Atrah S
    J Arthroplasty; 2009 Jan; 24(1):158.e5-8. PubMed ID: 18538535
    [TBL] [Abstract][Full Text] [Related]  

  • 40. [Relevance of the insertion force for the taper lock reliability of a hip stem and a ceramic femoral head].
    Nassutt R; Mollenhauer I; Klingbeil K; Henning O; Grundei H
    Biomed Tech (Berl); 2006 Jul; 51(2):103-9. PubMed ID: 16915773
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 7.