  • 21. [Application study on improving the methods of endotracheal cuff pressure measurement to prevent ventilator-associated pneumonia].
    Huang L; Zhang L; Meng L; Zhou C; Lin J; Li Y; Huang B; Chen Y
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2019 Aug; 31(8):1024-1027. PubMed ID: 31537232
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Changes in Pediatric-Sized Endotracheal Tube Cuff Pressure With Elevation Gain: Observations in Ex Vivo Simulations and In Vivo Air Medical Transport.
    Long MT; Cvijanovich NZ; McCalla GP; Flori HR
    Pediatr Emerg Care; 2018 Aug; 34(8):570-573. PubMed ID: 27164320
    [TBL] [Abstract][Full Text] [Related]  

  • 23. [Influence of intermittently monitoring on endotracheal tube cuff pressure using handheld pressure gauge].
    Huang L; Xie C; Zhang L; Meng L; Li G; Li Y; Huang B; Pan L; Tang Z
    Zhonghua Wei Zhong Bing Ji Jiu Yi Xue; 2017 Jan; 29(1):71-74. PubMed ID: 28459408
    [TBL] [Abstract][Full Text] [Related]  

  • 24. The minimal leak test technique for endotracheal cuff maintenance.
    Harvie DA; Darvall JN; Dodd M; De La Cruz A; Tacey M; D'Costa RL; Ward D
    Anaesth Intensive Care; 2016 Sep; 44(5):599-604. PubMed ID: 27608343
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Fluid leakage past tracheal tube cuffs: evaluation of the new Microcuff endotracheal tube.
    Dullenkopf A; Gerber A; Weiss M
    Intensive Care Med; 2003 Oct; 29(10):1849-53. PubMed ID: 12923620
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Endotracheal tube cuff pressure changes during manual cuff pressure control manoeuvres: An in-vitro assessment.
    Aeppli N; Lindauer B; Steurer MP; Weiss M; Dullenkopf A
    Acta Anaesthesiol Scand; 2019 Jan; 63(1):55-60. PubMed ID: 30132783
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Practicing paramedics cannot generate or estimate safe endotracheal tube cuff pressure using standard techniques.
    Parwani V; Hoffman RJ; Russell A; Bharel C; Preblick C; Hahn IH
    Prehosp Emerg Care; 2007; 11(3):307-11. PubMed ID: 17613904
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Effects of Increasing Airway Pressures on the Pressure of the Endotracheal Tube Cuff During Pelvic Laparoscopic Surgery.
    Rosero EB; Ozayar E; Eslava-Schmalbach J; Minhajuddin A; Joshi GP
    Anesth Analg; 2018 Jul; 127(1):120-125. PubMed ID: 29189283
    [TBL] [Abstract][Full Text] [Related]  

  • 29. A technique of placing cuffed endotracheal tubes through in situ paediatric laryngeal mask airways.
    Ho AM
    Anaesth Intensive Care; 2014 May; 42(3):330-2. PubMed ID: 24794472
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Accuracy of endotracheal tube cuff pressure adjustment by fingertip palpation after training of intensive care unit nurses.
    Maboudi A; Abtahi H; Hosseini M; Tamadon A; Safavi E
    Iran Red Crescent Med J; 2013 May; 15(5):381-4. PubMed ID: 24349723
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Measurement of endotracheal tube cuff pressure: Instrumental versus conventional method.
    Khan MU; Khokar R; Qureshi S; Al Zahrani T; Aqil M; Shiraz M
    Saudi J Anaesth; 2016; 10(4):428-431. PubMed ID: 27833487
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Evaluation in animals of a system to estimate tracheal pressure from the endotracheal tube cuff.
    Wilder NA; Orr J; Westenskow D
    J Clin Monit; 1996 Jan; 12(1):11-6. PubMed ID: 8732811
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Does the minimal occlusive volume technique provide adequate endotracheal tube cuff pressure to prevent air leakage?: a prospective, randomized, crossover clinical study.
    Park HY; Kim M; In J
    Anesth Pain Med (Seoul); 2020 Jul; 15(3):365-370. PubMed ID: 33329837
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Prevalence and predictors of out-of-range cuff pressure of endotracheal and tracheostomy tubes: a prospective cohort study in mechanically ventilated patients.
    Alzahrani AR; Al Abbasi S; Abahoussin OK; Al Shehri TO; Al-Dorzi HM; Tamim HM; Sadat M; Arabi YM
    BMC Anesthesiol; 2015 Oct; 15():147. PubMed ID: 26471790
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Endotracheal tube cuff pressure during laparoscopic bariatric surgery: highs and lows.
    Saxena D; Raghuwanshi J; Dixit A; Chaturvedi S
    Anesth Pain Med (Seoul); 2022 Jan; 17(1):98-103. PubMed ID: 35139611
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Changes in endotracheal tube cuff pressure in mechanically ventilated adult patients.
    Motoyama A; Asai S; Konami H; Matsumoto Y; Misumi T; Imanaka H; Nishimura M
    J Intensive Care; 2014; 2(1):7. PubMed ID: 25520824
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Passive Release Technique Produces the Most Accurate Endotracheal Tube Cuff Pressure Than Manual Palpation and Minimum Occlusive Volume Technique in the Absence of Manometer.
    Laksono BH; Isngadi I; Wicaksono SJ
    Turk J Anaesthesiol Reanim; 2021 Apr; 49(2):114-117. PubMed ID: 33997839
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Methods Used for Endotracheal Tube Cuff Inflation and Pressure Verification in Veterinary Medicine: A Questionnaire on Current Practice.
    Veen I; de Grauw JC
    Animals (Basel); 2022 Nov; 12(22):. PubMed ID: 36428304
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Endotracheal tube cuff pressure in three hospitals, and the volume required to produce an appropriate cuff pressure.
    Sengupta P; Sessler DI; Maglinger P; Wells S; Vogt A; Durrani J; Wadhwa A
    BMC Anesthesiol; 2004 Nov; 4(1):8. PubMed ID: 15569386
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Comparison of the endotracheal tube cuff pressure between a tapered- versus a cylindrical-shaped cuff after changing from the supine to the lateral flank position.
    Kim HC; Lee YH; Kim E; Oh EA; Jeon YT; Park HP
    Can J Anaesth; 2015 Oct; 62(10):1063-70. PubMed ID: 25894912
    [TBL] [Abstract][Full Text] [Related]  