BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

621 related articles for article (PubMed ID: 25913223)

  • 1. A quality improvement initiative to optimize use of a mechanical chest compression device within a high-performance CPR approach to out-of-hospital cardiac arrest resuscitation.
    Levy M; Yost D; Walker RG; Scheunemann E; Mendive SR
    Resuscitation; 2015 Jul; 92():32-7. PubMed ID: 25913223
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Mechanical chest compressions improved aspects of CPR in the LINC trial.
    Esibov A; Banville I; Chapman FW; Boomars R; Box M; Rubertsson S
    Resuscitation; 2015 Jun; 91():116-21. PubMed ID: 25766094
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Assessment of CPR interruptions from transthoracic impedance during use of the LUCAS™ mechanical chest compression system.
    Yost D; Phillips RH; Gonzales L; Lick CJ; Satterlee P; Levy M; Barger J; Dodson P; Poggi S; Wojcik K; Niskanen RA; Chapman FW
    Resuscitation; 2012 Aug; 83(8):961-5. PubMed ID: 22310728
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The combined use of mechanical CPR and a carry sheet to maintain quality resuscitation in out-of-hospital cardiac arrest patients during extrication and transport.
    Lyon RM; Crawford A; Crookston C; Short S; Clegg GR
    Resuscitation; 2015 Aug; 93():102-6. PubMed ID: 26079791
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Quality of cardiopulmonary resuscitation in out-of-hospital cardiac arrest before and after introduction of a mechanical chest compression device, LUCAS-2; a prospective, observational study.
    Tranberg T; Lassen JF; Kaltoft AK; Hansen TM; Stengaard C; Knudsen L; Trautner S; Terkelsen CJ
    Scand J Trauma Resusc Emerg Med; 2015 Apr; 23():37. PubMed ID: 25898992
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Compressions during defibrillator charging shortens shock pause duration and improves chest compression fraction during shockable out of hospital cardiac arrest.
    Cheskes S; Common MR; Byers PA; Zhan C; Morrison LJ
    Resuscitation; 2014 Aug; 85(8):1007-11. PubMed ID: 24830868
    [TBL] [Abstract][Full Text] [Related]  

  • 7. No Benefit in Neurologic Outcomes of Survivors of Out-of-Hospital Cardiac Arrest with Mechanical Compression Device.
    Newberry R; Redman T; Ross E; Ely R; Saidler C; Arana A; Wampler D; Miramontes D
    Prehosp Emerg Care; 2018; 22(3):338-344. PubMed ID: 29345513
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The influence of scenario-based training and real-time audiovisual feedback on out-of-hospital cardiopulmonary resuscitation quality and survival from out-of-hospital cardiac arrest.
    Bobrow BJ; Vadeboncoeur TF; Stolz U; Silver AE; Tobin JM; Crawford SA; Mason TK; Schirmer J; Smith GA; Spaite DW
    Ann Emerg Med; 2013 Jul; 62(1):47-56.e1. PubMed ID: 23465553
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Prehospital randomised assessment of a mechanical compression device in out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised trial and economic evaluation.
    Gates S; Lall R; Quinn T; Deakin CD; Cooke MW; Horton J; Lamb SE; Slowther AM; Woollard M; Carson A; Smyth M; Wilson K; Parcell G; Rosser A; Whitfield R; Williams A; Jones R; Pocock H; Brock N; Black JJ; Wright J; Han K; Shaw G; Blair L; Marti J; Hulme C; McCabe C; Nikolova S; Ferreira Z; Perkins GD
    Health Technol Assess; 2017 Mar; 21(11):1-176. PubMed ID: 28393757
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Pre-shock chest compression pause effects on termination of ventricular fibrillation/tachycardia and return of organized rhythm within mechanical and manual cardiopulmonary resuscitation.
    Olsen JA; Brunborg C; Steinberg M; Persse D; Sterz F; Lozano M; Westfall M; Travis DT; Lerner EB; Brouwer MA; Wik L
    Resuscitation; 2015 Aug; 93():158-63. PubMed ID: 25933511
    [TBL] [Abstract][Full Text] [Related]  

  • 11. The impact of post-resuscitation feedback for paramedics on the quality of cardiopulmonary resuscitation.
    Bleijenberg E; Koster RW; de Vries H; Beesems SG
    Resuscitation; 2017 Jan; 110():1-5. PubMed ID: 27751861
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Quality of bystander cardiopulmonary resuscitation during real-life out-of-hospital cardiac arrest.
    Gyllenborg T; Granfeldt A; Lippert F; Riddervold IS; Folke F
    Resuscitation; 2017 Nov; 120():63-70. PubMed ID: 28903056
    [TBL] [Abstract][Full Text] [Related]  

  • 13. The Efficacy of LUCAS in Prehospital Cardiac Arrest Scenarios: A Crossover Mannequin Study.
    Gyory RA; Buchle SE; Rodgers D; Lubin JS
    West J Emerg Med; 2017 Apr; 18(3):437-445. PubMed ID: 28435494
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Mechanical versus manual chest compression for out-of-hospital cardiac arrest (PARAMEDIC): a pragmatic, cluster randomised controlled trial.
    Perkins GD; Lall R; Quinn T; Deakin CD; Cooke MW; Horton J; Lamb SE; Slowther AM; Woollard M; Carson A; Smyth M; Whitfield R; Williams A; Pocock H; Black JJ; Wright J; Han K; Gates S;
    Lancet; 2015 Mar; 385(9972):947-55. PubMed ID: 25467566
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Manual chest compression vs use of an automated chest compression device during resuscitation following out-of-hospital cardiac arrest: a randomized trial.
    Hallstrom A; Rea TD; Sayre MR; Christenson J; Anton AR; Mosesso VN; Van Ottingham L; Olsufka M; Pennington S; White LJ; Yahn S; Husar J; Morris MF; Cobb LA
    JAMA; 2006 Jun; 295(22):2620-8. PubMed ID: 16772625
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incomplete chest wall decompression: a clinical evaluation of CPR performance by EMS personnel and assessment of alternative manual chest compression-decompression techniques.
    Aufderheide TP; Pirrallo RG; Yannopoulos D; Klein JP; von Briesen C; Sparks CW; Deja KA; Conrad CJ; Kitscha DJ; Provo TA; Lurie KG
    Resuscitation; 2005 Mar; 64(3):353-62. PubMed ID: 15733766
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Self-Assessment Feedback Form Improves Quality of Out-of-Hospital CPR.
    Weston BW; Jasti J; Mena M; Unteriner J; Tillotson K; Yin Z; Colella MR; Aufderheide TP
    Prehosp Emerg Care; 2019; 23(1):66-73. PubMed ID: 30118617
    [No Abstract]   [Full Text] [Related]  

  • 18. Advanced Airway Type and Its Association with Chest Compression Interruptions During Out-of-Hospital Cardiac Arrest Resuscitation Attempts.
    Jarman AF; Hopkins CL; Hansen JN; Brown JR; Burk C; Youngquist ST
    Prehosp Emerg Care; 2017; 21(5):628-635. PubMed ID: 28459305
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Enhancing CPR During Transition From Prehospital to Emergency Department: A QI Initiative.
    Hoehn EF; Cabrera-Thurman MK; Oehler J; Vukovic A; Frey M; Helton M; Geis G; Kerrey B
    Pediatrics; 2020 May; 145(5):. PubMed ID: 32299822
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Pauses in compressions during pediatric CPR: Opportunities for improving CPR quality.
    O'Connell KJ; Keane RR; Cochrane NH; Sandler AB; Donoghue AJ; Kerrey BT; Myers SR; Vazifedan T; Mullan PC
    Resuscitation; 2019 Dec; 145():158-165. PubMed ID: 31421191
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 32.