These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
266 related articles for article (PubMed ID: 2591398)
1. Radiofrequency coagulation of ventricular myocardium: improved prediction of lesion size by monitoring catheter tip temperature. Hindricks G; Haverkamp W; Gülker H; Rissel U; Budde T; Richter KD; Borggrefe M; Breithardt G Eur Heart J; 1989 Nov; 10(11):972-84. PubMed ID: 2591398 [TBL] [Abstract][Full Text] [Related]
2. Advanced radiofrequency catheter ablation in canine myocardium. Rosenbaum R; Greenspon AJ; Smith M; Walinsky P Am Heart J; 1994 Apr; 127(4 Pt 1):851-7. PubMed ID: 8154424 [TBL] [Abstract][Full Text] [Related]
3. [Biophysical aspects of high frequency catheter ablation. Studies of the significance of sudden changes in impedance]. Kottkamp H; Hindricks G; Haverkamp W; Krater L; Borggrefe M; Böcker D; Gülker H; Breithardt G Z Kardiol; 1992 Mar; 81(3):145-51. PubMed ID: 1585711 [TBL] [Abstract][Full Text] [Related]
4. Coagulation of ventricular myocardium using radiofrequency alternating current: bio-physical aspects and experimental findings. Haverkamp W; Hindricks G; Gulker H; Rissel U; Pfennings W; Borggrefe M; Breithardt G Pacing Clin Electrophysiol; 1989 Jan; 12(1 Pt 2):187-95. PubMed ID: 2466252 [TBL] [Abstract][Full Text] [Related]
5. Catheter ablation of atrioventricular junction using radiofrequency current in 17 patients. Comparison of standard and large-tip catheter electrodes. Jackman WM; Wang XZ; Friday KJ; Fitzgerald DM; Roman C; Moulton K; Margolis PD; Bowman AJ; Kuck KH; Naccarelli GV Circulation; 1991 May; 83(5):1562-76. PubMed ID: 2022016 [TBL] [Abstract][Full Text] [Related]
6. Comparison of in vivo tissue temperature profile and lesion geometry for radiofrequency ablation with a saline-irrigated electrode versus temperature control in a canine thigh muscle preparation. Nakagawa H; Yamanashi WS; Pitha JV; Arruda M; Wang X; Ohtomo K; Beckman KJ; McClelland JH; Lazzara R; Jackman WM Circulation; 1995 Apr; 91(8):2264-73. PubMed ID: 7697856 [TBL] [Abstract][Full Text] [Related]
8. Lesion dimensions during temperature-controlled radiofrequency catheter ablation of left ventricular porcine myocardium: impact of ablation site, electrode size, and convective cooling. Høgh Petersen H; Chen X; Pietersen A; Svendsen JH; Haunsø S Circulation; 1999 Jan; 99(2):319-25. PubMed ID: 9892601 [TBL] [Abstract][Full Text] [Related]
9. Cooled-tip ablation results in increased radiofrequency power delivery and lesion size in the canine heart: importance of catheter-tip temperature monitoring for prevention of popping and impedance rise. Watanabe I; Masaki R; Min N; Oshikawa N; Okubo K; Sugimura H; Kojima T; Saito S; Ozawa Y; Kanmatsuse K J Interv Card Electrophysiol; 2002 Feb; 6(1):9-16. PubMed ID: 11839878 [TBL] [Abstract][Full Text] [Related]
10. Transcatheter cryoablation of ventricular myocardium in dogs. Wadhwa MK; Rahme MM; Dobak J; Li H; Wolf P; Chen P; Feld GK J Interv Card Electrophysiol; 2000 Oct; 4(3):537-45. PubMed ID: 11046193 [TBL] [Abstract][Full Text] [Related]
11. Temperature measurement as a determinant of tissue heating during radiofrequency catheter ablation: an examination of electrode thermistor positioning for measurement accuracy. McRury ID; Whayne JG; Haines DE J Cardiovasc Electrophysiol; 1995 Apr; 6(4):268-78. PubMed ID: 7647952 [TBL] [Abstract][Full Text] [Related]
12. Transcatheter desiccation of the canine left ventricle using radiofrequency energy: a pilot study. Huang SK; Graham AR; Hoyt RH; Odell RC Am Heart J; 1987 Jul; 114(1 Pt 1):42-8. PubMed ID: 3604872 [TBL] [Abstract][Full Text] [Related]
13. Radiofrequency catheter ablation: different cooled and noncooled electrode systems induce specific lesion geometries and adverse effects profiles. Dorwarth U; Fiek M; Remp T; Reithmann C; Dugas M; Steinbeck G; Hoffmann E Pacing Clin Electrophysiol; 2003 Jul; 26(7 Pt 1):1438-45. PubMed ID: 12914619 [TBL] [Abstract][Full Text] [Related]
14. Relationship between catheter contact force and radiofrequency lesion size and incidence of steam pop in the beating canine heart: electrogram amplitude, impedance, and electrode temperature are poor predictors of electrode-tissue contact force and lesion size. Ikeda A; Nakagawa H; Lambert H; Shah DC; Fonck E; Yulzari A; Sharma T; Pitha JV; Lazzara R; Jackman WM Circ Arrhythm Electrophysiol; 2014 Dec; 7(6):1174-80. PubMed ID: 25381331 [TBL] [Abstract][Full Text] [Related]
15. Tissue temperatures and lesion size during irrigated tip catheter radiofrequency ablation: an in vitro comparison of temperature-controlled irrigated tip ablation, power-controlled irrigated tip ablation, and standard temperature-controlled ablation. Petersen HH; Chen X; Pietersen A; Svendsen JH; Haunsø S Pacing Clin Electrophysiol; 2000 Jan; 23(1):8-17. PubMed ID: 10666748 [TBL] [Abstract][Full Text] [Related]
16. Tissue heating during radiofrequency catheter ablation: a thermodynamic model and observations in isolated perfused and superfused canine right ventricular free wall. Haines DE; Watson DD Pacing Clin Electrophysiol; 1989 Jun; 12(6):962-76. PubMed ID: 2472624 [TBL] [Abstract][Full Text] [Related]
17. Observations on electrode-tissue interface temperature and effect on electrical impedance during radiofrequency ablation of ventricular myocardium. Haines DE; Verow AF Circulation; 1990 Sep; 82(3):1034-8. PubMed ID: 2393987 [TBL] [Abstract][Full Text] [Related]
18. [Is radiofrequency catheter ablation available for treatment of ventricular tachycardias?--Effects of sequential unipolar applications using multiple electrode catheter]. Ikeda T; Ninomiya K; Sugi K; Enjoji Y; Abe R; Yamaguchi T; Yabuki S Kokyu To Junkan; 1992 May; 40(5):467-72. PubMed ID: 1589645 [TBL] [Abstract][Full Text] [Related]