BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

773 related articles for article (PubMed ID: 25918348)

  • 1. Volar locking plates versus K-wire/pin fixation for the treatment of distal radial fractures: a systematic review and quantitative synthesis.
    Franceschi F; Franceschetti E; Paciotti M; Cancilleri F; Maffulli N; Denaro V
    Br Med Bull; 2015 Sep; 115(1):91-110. PubMed ID: 25918348
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Are Volar Locking Plates Superior to Percutaneous K-wires for Distal Radius Fractures? A Meta-analysis.
    Chaudhry H; Kleinlugtenbelt YV; Mundi R; Ristevski B; Goslings JC; Bhandari M
    Clin Orthop Relat Res; 2015 Sep; 473(9):3017-27. PubMed ID: 25981715
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires.
    Zong SL; Kan SL; Su LX; Wang B
    J Orthop Surg Res; 2015 Jul; 10():108. PubMed ID: 26169601
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Comparison between Carbon-Peek volar locking plates and titanium volar locking plates in the treatment of distal radius fractures.
    Perugia D; Guzzini M; Mazza D; Iorio C; Civitenga C; Ferretti A
    Injury; 2017 Oct; 48 Suppl 3():S24-S29. PubMed ID: 29025605
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Percutaneous fixation with Kirschner wires versus volar locking-plate fixation in adults with dorsally displaced fracture of distal radius: five-year follow-up of a randomized controlled trial.
    Costa ML; Achten J; Rangan A; Lamb SE; Parsons NR
    Bone Joint J; 2019 Aug; 101-B(8):978-983. PubMed ID: 31362548
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volar locking plates versus Kirschner wires for distal radial fractures--a cost analysis study.
    Shyamalan G; Theokli C; Pearse Y; Tennent D
    Injury; 2009 Dec; 40(12):1279-81. PubMed ID: 19524910
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Volar locking plating versus percutaneous Kirschner wires for distal radius fractures in an adult population: a meta-analysis.
    Youlden DJ; Sundaraj K; Smithers C
    ANZ J Surg; 2019 Jul; 89(7-8):821-826. PubMed ID: 30354018
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Volar Locking Plate or External Fixation With Optional Addition of K-Wires for Dorsally Displaced Distal Radius Fractures: A Randomized Controlled Study.
    Mellstrand Navarro C; Ahrengart L; Törnqvist H; Ponzer S
    J Orthop Trauma; 2016 Apr; 30(4):217-24. PubMed ID: 26709818
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Volar locking plate (VLP) versus non-locking plate (NLP) in the treatment of die-punch fractures of the distal radius, an observational study.
    Zhang X; Hu C; Yu K; Bai J; Tian D; Xu Y; Zhang B
    Int J Surg; 2016 Oct; 34():142-147. PubMed ID: 27593172
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Volar plate versus k-wire fixation of distal radius fractures.
    Brennan SA; Kiernan C; Beecher S; O'Reilly RT; Devitt BM; Kearns SR; O'Sullivan ME
    Injury; 2016 Feb; 47(2):372-6. PubMed ID: 26592093
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Volar locking plates versus external fixation and adjuvant pin fixation in unstable distal radius fractures: a randomized, controlled study.
    Williksen JH; Frihagen F; Hellund JC; Kvernmo HD; Husby T
    J Hand Surg Am; 2013 Aug; 38(8):1469-76. PubMed ID: 23890493
    [TBL] [Abstract][Full Text] [Related]  

  • 12. POWIFF- Prospective study of wrist internal fixation of fracture: A protocol for a single centre, superiority, randomised controlled trial to study the efficacy of the VRP (2.0) distal radius plate (Austofix) versus the VA-LCP (Depuy-Synthes) for distal radius fractures.
    Varghese VD; Smitham P; Howell S; Edwards S; Rickman M
    BMC Musculoskelet Disord; 2018 Apr; 19(1):131. PubMed ID: 29712566
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Surgical treatment of distal radial fractures with a volar locking plate versus conventional percutaneous methods: a randomized controlled trial.
    Karantana A; Downing ND; Forward DP; Hatton M; Taylor AM; Scammell BE; Moran CG; Davis TR
    J Bone Joint Surg Am; 2013 Oct; 95(19):1737-44. PubMed ID: 24088965
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Percutaneous fixation with Kirschner wires versus volar locking plate fixation in adults with dorsally displaced fracture of distal radius: randomised controlled trial.
    Costa ML; Achten J; Parsons NR; Rangan A; Griffin D; Tubeuf S; Lamb SE;
    BMJ; 2014 Aug; 349():g4807. PubMed ID: 25096595
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Surgical treatment of unstable distal radius fractures with volar locking plates.
    Murakami K; Abe Y; Takahashi K
    J Orthop Sci; 2007 Mar; 12(2):134-40. PubMed ID: 17393268
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Cast immobilization versus volar locking plate fixation of AO type C distal radial fractures in patients aged 60 years and older.
    Zengin EC; Ozcan C; Aslan C; Bulut T; Sener M
    Acta Orthop Traumatol Turc; 2019 Jan; 53(1):15-18. PubMed ID: 30377011
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Dorsal and volar 2.4-mm titanium locking plate fixation for AO type C3 dorsally comminuted distal radius fractures.
    Chou YC; Chen AC; Chen CY; Hsu YH; Wu CC
    J Hand Surg Am; 2011 Jun; 36(6):974-81. PubMed ID: 21549526
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Effect of calcium phosphate bone cement augmentation on volar plate fixation of unstable distal radial fractures in the elderly.
    Kim JK; Koh YD; Kook SH
    J Bone Joint Surg Am; 2011 Apr; 93(7):609-14. PubMed ID: 21471414
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Dorsally displaced extra-articular distal radius fractures fixation: Dorsal IM nailing versus volar plating. A randomized controlled trial.
    Chappuis J; Bouté P; Putz P
    Orthop Traumatol Surg Res; 2011 Sep; 97(5):471-8. PubMed ID: 21659011
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Fragment-Specific Fixation Versus Volar Locking Plates in Primarily Nonreducible or Secondarily Redisplaced Distal Radius Fractures: A Randomized Controlled Study.
    Landgren M; Abramo A; Geijer M; Kopylov P; Tägil M
    J Hand Surg Am; 2017 Mar; 42(3):156-165.e1. PubMed ID: 28089163
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 39.