These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

165 related articles for article (PubMed ID: 2591941)

  • 1. [A fast determination of serum bilirubin with the interference from hemolysis and turbidity by three wavelength spectrophotometry].
    Chai H; Dong YH
    Hua Xi Yi Ke Da Xue Xue Bao; 1989 Jun; 20(2):223-5. PubMed ID: 2591941
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Direct spectrophotometry of serum hemoglobin: an Allen correction compared with a three-wavelength polychromatic analysis.
    Noe DA; Weedn V; Bell WR
    Clin Chem; 1984 May; 30(5):627-30. PubMed ID: 6713623
    [TBL] [Abstract][Full Text] [Related]  

  • 3. [Haemolysis and turbidity influence on three analysis methods of quantitative determination of total and conjugated bilirubin on ADVIA 1650].
    Gobert De Paepe E; Munteanu G; Schischmanoff PO; Porquet D
    Ann Biol Clin (Paris); 2008; 66(2):175-82. PubMed ID: 18390427
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The influence of bilirubin, haemolysis and turbidity on 20 analytical tests performed on automatic analysers. Results of an interlaboratory study.
    Grafmeyer D; Bondon M; Manchon M; Levillain P
    Eur J Clin Chem Clin Biochem; 1995 Jan; 33(1):31-52. PubMed ID: 7756439
    [TBL] [Abstract][Full Text] [Related]  

  • 5. [Influence of visible interferences on biochemical assays realised on Au 5231, AU 5223 (Olympus) and CL 7200 (Shimadzu)].
    Frémont S; Combe AM; Mecrin M; Tronel H; Galland AV; Scholl C; Nicolas JP
    Ann Biol Clin (Paris); 1996; 54(8-9):309-20. PubMed ID: 9092310
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Automated Jendrassik-Grof method for measurement of bilirubin in serum with the Greiner Selective Analyzer (GSA II D), and comparison with the method involving diazotized 2,4-dichloroaniline.
    Cherian AG; Soldin SJ; Hill JG
    Clin Chem; 1981 May; 27(5):748-52. PubMed ID: 7226499
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Unreliable visual estimation of the incidence and amount of turbidity, hemolysis, and icterus in serum from hospitalized patients.
    Glick MR; Ryder KW; Glick SJ; Woods JR
    Clin Chem; 1989 May; 35(5):837-9. PubMed ID: 2720981
    [TBL] [Abstract][Full Text] [Related]  

  • 8. A robust procedure for the automated measurement of total serum bilirubin using potassium ferricyanide.
    O'Leary N; Pembroke A; Duggan PF
    Ann Clin Biochem; 1993 Mar; 30 ( Pt 2)():175-9. PubMed ID: 8466149
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Direct determination of total serum cholesterol by use of double-wavelength spectrophotometry.
    Sommers PB; Jatlow PI; Seligson D
    Clin Chem; 1975 May; 21(6):703-7. PubMed ID: 1122613
    [TBL] [Abstract][Full Text] [Related]  

  • 10. A bichromatic method for total bilirubin with a CentrifiChem 400.
    Kelly A; McKenna JP; McLelland A; Percy RA; Spooner RJ
    Clin Chem; 1979 Aug; 25(8):1482-4. PubMed ID: 455689
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mechanism of interference by hemoglobin in the determination of total bilirubin. I. Method of Malloy-Evelyn.
    Shull BC; Lees H; Li PK
    Clin Chem; 1980 Jan; 26(1):22-5. PubMed ID: 7356566
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Modification of the DuPont aca as exemplified by a new procedure for neonatal total bilirubin.
    Fraser AD; Lindsay AL
    Clin Chem; 1979 Oct; 25(10):1839-41. PubMed ID: 476938
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A spectrophotometric scanning technique for the rapid determination of plasma hemoglobin.
    Blakney GB; Dinwoodie AJ
    Clin Biochem; 1975 Apr; 8(2):96-102. PubMed ID: 236098
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Direct spectrophotometry of bilirubin in serum of the newborn, with use of caffeine reagent.
    Vink KL; Schuurman W; van Gansewinkel R
    Clin Chem; 1988 Jan; 34(1):67-70. PubMed ID: 3338189
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Correction of patient results for Beckman Coulter LX-20 assays affected by interference due to hemoglobin, bilirubin or lipids: a practical approach.
    Vermeer HJ; Steen G; Naus AJ; Goevaerts B; Agricola PT; Schoenmakers CH
    Clin Chem Lab Med; 2007; 45(1):114-9. PubMed ID: 17243928
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Evaluation of hemoglobin interference in capillary heel-stick samples collected for determination of neonatal bilirubin.
    Algeciras-Schimnich A; Cook WJ; Milz TC; Saenger AK; Karon BS
    Clin Biochem; 2007 Nov; 40(16-17):1311-6. PubMed ID: 17825810
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A single nonaqueous diazo reagent for the rapid determination of bilirubin in serum without lipemic interference.
    Morin LG
    Clin Chim Acta; 1976 Aug; 71(1):9-14. PubMed ID: 971528
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Measurement of total bilirubin by use of bilirubin oxidase.
    Perry B; Doumas BT; Buffone G; Glick M; Ou CN; Ryder K
    Clin Chem; 1986 Feb; 32(2):329-32. PubMed ID: 3943192
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Mechanism of interference by hemoglobin in the determination of total bilirubin. II. Method of Jendrassik-Grof.
    Shull BC; Lees H; Li PK
    Clin Chem; 1980 Jan; 26(1):26-9. PubMed ID: 7356567
    [TBL] [Abstract][Full Text] [Related]  

  • 20. [Correction of haptoglobin contents in hemolytic specimen with addition of saturated hemoglobin].
    Okazaki T; Arakawa H
    Rinsho Byori; 1992 May; 40(5):557-62. PubMed ID: 1507484
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 9.