These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

154 related articles for article (PubMed ID: 25920898)

  • 21. In vitro testing of a newly developed arteriovenous double-outflow graft.
    Heise M; Kirschner P; Rabsch A; Zanow J; Settmacher U; Heidenhain C
    J Vasc Surg; 2010 Aug; 52(2):421-8. PubMed ID: 20591600
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Hemodynamic impact of anastomosis size and angle in side-to-end arteriovenous fistulae: a computer analysis.
    Van Canneyt K; Pourchez T; Eloot S; Guillame C; Bonnet A; Segers P; Verdonck P
    J Vasc Access; 2010; 11(1):52-8. PubMed ID: 20119922
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Hemodynamic wall shear stress profiles influence the magnitude and pattern of stenosis in a pig AV fistula.
    Krishnamoorthy MK; Banerjee RK; Wang Y; Zhang J; Sinha Roy A; Khoury SF; Arend LJ; Rudich S; Roy-Chaudhury P
    Kidney Int; 2008 Dec; 74(11):1410-9. PubMed ID: 18818686
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Radial artery wall shear stress evaluation in patients with arteriovenous fistula for hemodialysis access.
    Remuzzi A; Ene-Iordache B; Mosconi L; Bruno S; Anghileri A; Antiga L; Remuzzi G
    Biorheology; 2003; 40(1-3):423-30. PubMed ID: 12454436
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Validation of a patient-specific hemodynamic computational model for surgical planning of vascular access in hemodialysis patients.
    Caroli A; Manini S; Antiga L; Passera K; Ene-Iordache B; Rota S; Remuzzi G; Bode A; Leermakers J; van de Vosse FN; Vanholder R; Malovrh M; Tordoir J; Remuzzi A;
    Kidney Int; 2013 Dec; 84(6):1237-45. PubMed ID: 23715122
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Flow-induced high frequency vascular wall vibrations in an arteriovenous fistula: a specific stimulus for stenosis development?
    Bozzetto M; Remuzzi A; Valen-Sendstad K
    Phys Eng Sci Med; 2024 Mar; 47(1):187-197. PubMed ID: 38157188
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Frequency of swing-segment stenosis in referred dialysis patients with angiographically documented lesions.
    Badero OJ; Salifu MO; Wasse H; Work J
    Am J Kidney Dis; 2008 Jan; 51(1):93-8. PubMed ID: 18155537
    [TBL] [Abstract][Full Text] [Related]  

  • 28. The presence of helical flow can suppress areas of disturbed shear in parameterised models of an arteriovenous fistula.
    Cunnane CV; Cunnane EM; Moran DT; Walsh MT
    Int J Numer Method Biomed Eng; 2019 Dec; 35(12):e3259. PubMed ID: 31483945
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Applicability of an entry flow model of the brachial artery for flow models of the hemodialysis fistula.
    Bastola S; Paulson WD; Jones SA
    Proc Inst Mech Eng H; 2017 Aug; 231(8):766-773. PubMed ID: 28466757
    [TBL] [Abstract][Full Text] [Related]  

  • 30. Flow and wall shear stress in end-to-side and side-to-side anastomosis of venous coronary artery bypass grafts.
    Frauenfelder T; Boutsianis E; Schertler T; Husmann L; Leschka S; Poulikakos D; Marincek B; Alkadhi H
    Biomed Eng Online; 2007 Sep; 6():35. PubMed ID: 17897460
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Simulations of the blood flow in the arterio-venous fistula for haemodialysis.
    Jodko D; Obidowski D; Reorowicz P; Jóźwik K
    Acta Bioeng Biomech; 2014; 16(1):69-74. PubMed ID: 24708294
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Arteriovenous Fistulas and Their Characteristic Sites of Stenosis.
    Quencer KB; Arici M
    AJR Am J Roentgenol; 2015 Oct; 205(4):726-34. PubMed ID: 26397321
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Numerical evaluation and experimental validation of vascular access stenosis estimation.
    Chen W; Kan CD; Kao RH
    Technol Health Care; 2015; 24 Suppl 1():S245-52. PubMed ID: 26684568
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Sequential venous anastomosis design to enhance patency of arterio-venous grafts for hemodialysis.
    Kabinejadian F; Su B; Ghista DN; Ismail M; Kim S; Leo HL
    Comput Methods Biomech Biomed Engin; 2017 Jan; 20(1):85-93. PubMed ID: 27328413
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Arteriovenous fistula maturation and the influence of fluid dynamics.
    Colley E; Simmons A; Varcoe R; Thomas S; Barber T
    Proc Inst Mech Eng H; 2020 Nov; 234(11):1197-1208. PubMed ID: 32597295
    [TBL] [Abstract][Full Text] [Related]  

  • 36. In vitro hemodynamic model of the arm arteriovenous circulation to study hemodynamics of native arteriovenous fistula and the distal revascularization and interval ligation procedure.
    Varble N; Day S; Phillips D; Mix D; Schwarz K; Illig KA; Chandra A
    J Vasc Surg; 2014 May; 59(5):1410-7. PubMed ID: 23845661
    [TBL] [Abstract][Full Text] [Related]  

  • 37. The Hemodynamic Effects of Hemodialysis Needle Rotation and Orientation in an Idealized Computational Model.
    Fulker D; Simmons A; Kabir K; Kark L; Barber T
    Artif Organs; 2016 Feb; 40(2):185-9. PubMed ID: 26011083
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The Role of Shear Stress in Arteriovenous Fistula Maturation and Failure: A Systematic Review.
    Browne LD; Bashar K; Griffin P; Kavanagh EG; Walsh SR; Walsh MT
    PLoS One; 2015; 10(12):e0145795. PubMed ID: 26716840
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Analysis of Computational Fluid Dynamics and Particle Image Velocimetry Models of Distal-End Side-to-Side and End-to-Side Anastomoses for Coronary Artery Bypass Grafting in a Pulsatile Flow.
    Shintani Y; Iino K; Yamamoto Y; Kato H; Takemura H; Kiwata T
    Circ J; 2017 Dec; 82(1):110-117. PubMed ID: 28824030
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Computational Fluid Dynamic Analysis of the Hemodialysis Plastic Cannula.
    Fulker D; Sayed Z; Simmons A; Barber T
    Artif Organs; 2017 Nov; 41(11):1035-1042. PubMed ID: 28591486
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 8.