154 related articles for article (PubMed ID: 2592481)
21. A novel nanospray capillary zone electrophoresis/mass spectrometry interface.
Hsieh F; Baronas E; Muir C; Martin SA
Rapid Commun Mass Spectrom; 1999; 13(1):67-72. PubMed ID: 9921690
[TBL] [Abstract][Full Text] [Related]
22. Production of Over 27 000 Peptide and Nearly 4400 Protein Identifications by Single-Shot Capillary-Zone Electrophoresis-Mass Spectrometry via Combination of a Very-Low-Electroosmosis Coated Capillary, a Third-Generation Electrokinetically-Pumped Sheath-Flow Nanospray Interface, an Orbitrap Fusion Lumos Tribrid Mass Spectrometer, and an Advanced-Peak-Determination Algorithm.
Zhang Z; Hebert AS; Westphall MS; Qu Y; Coon JJ; Dovichi NJ
Anal Chem; 2018 Oct; 90(20):12090-12093. PubMed ID: 30179504
[TBL] [Abstract][Full Text] [Related]
23. Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex.
Choi SB; Zamarbide M; Manzini MC; Nemes P
J Am Soc Mass Spectrom; 2017 Apr; 28(4):597-607. PubMed ID: 27853976
[TBL] [Abstract][Full Text] [Related]
24. Application of electrospray ionization mass spectrometry and tandem mass spectrometry in combination with capillary electrophoresis for biochemical investigations.
Edmonds CG; Loo JA; Loo RR; Udseth HR; Barinaga CJ; Smith RD
Biochem Soc Trans; 1991 Nov; 19(4):943-7. PubMed ID: 1794588
[No Abstract] [Full Text] [Related]
25. Capillary electrophoresis/electrospray ionization high mass accuracy time-of-flight mass spectrometry for protein identification using peptide mapping.
Cao P; Moini M
Rapid Commun Mass Spectrom; 1998; 12(13):864-70. PubMed ID: 9684380
[TBL] [Abstract][Full Text] [Related]
26. Recent developments in capillary electrophoresis-mass spectrometry of proteins and peptides.
Monton MR; Terabe S
Anal Sci; 2005 Jan; 21(1):5-13. PubMed ID: 15675508
[TBL] [Abstract][Full Text] [Related]
27. Pressurized electrochromatography coupled with electrospray ionization mass spectrometry for analysis of peptides and proteins.
Liang Z; Duan J; Zhang L; Zhang W; Zhang Y; Yan C
Anal Chem; 2004 Dec; 76(23):6935-40. PubMed ID: 15571344
[TBL] [Abstract][Full Text] [Related]
28. Electrophoresis combined with novel mass spectrometry techniques: powerful tools for the analysis of proteins and proteomes.
Figeys D; Gygi SP; Zhang Y; Watts J; Gu M; Aebersold R
Electrophoresis; 1998 Jul; 19(10):1811-8. PubMed ID: 9719564
[TBL] [Abstract][Full Text] [Related]
29. High sensitivity identification of proteins by electrospray ionization tandem mass spectrometry: initial comparison between an ion trap mass spectrometer and a triple quadrupole mass spectrometer.
Figeys D; Aebersold R
Electrophoresis; 1997; 18(3-4):360-8. PubMed ID: 9150914
[TBL] [Abstract][Full Text] [Related]
30. Design of a sheathless capillary eletrophoresis-mass spectrometry probe for operation with a Z-spray ionization source.
McComb ME; Perreault H
Electrophoresis; 2000 Apr; 21(7):1354-62. PubMed ID: 10826681
[TBL] [Abstract][Full Text] [Related]
31. Sheathless capillary electrophoresis/electrospray ionization mass spectrometry using a pulled bare fused-silica capillary as the electrospray emitter.
Wu YT; Chen YC
Anal Chem; 2005 Apr; 77(7):2071-7. PubMed ID: 15801740
[TBL] [Abstract][Full Text] [Related]
32. High sequence coverage by in-capillary proteolysis of native proteins and simultaneous analysis of the resulting peptides by nanoelectrospray ionization-mass spectrometry and tandem mass spectrometry.
Pohlentz G; Kölbl S; Peter-Katalinić J
Proteomics; 2005 May; 5(7):1758-63. PubMed ID: 15761958
[TBL] [Abstract][Full Text] [Related]
33. A robust approach for the analysis of peptides in the low femtomole range by capillary electrophoresis-tandem mass spectrometry.
Neusüss C; Pelzing M; Macht M
Electrophoresis; 2002 Sep; 23(18):3149-59. PubMed ID: 12298087
[TBL] [Abstract][Full Text] [Related]
34. An on-line preconcentrator and the evaluation of electrospray interfaces for the capillary electrophoresis/mass spectrometry of peptides.
Herring CJ; Qin J
Rapid Commun Mass Spectrom; 1999; 13(1):1-7. PubMed ID: 9921685
[TBL] [Abstract][Full Text] [Related]
35. On-line coupling of capillary isoelectric focusing with transient isotachophoresis-zone electrophoresis: a two-dimensional separation system for proteomics.
Mohan D; Lee CS
Electrophoresis; 2002 Sep; 23(18):3160-7. PubMed ID: 12298088
[TBL] [Abstract][Full Text] [Related]
36. Microfabricated device coupled with an electrospray ionization quadrupole time-of-flight mass spectrometer: protein identifications based on enhanced-resolution mass spectrometry and tandem mass spectrometry data.
Figeys D; Lock C; Taylor L; Aebersold R
Rapid Commun Mass Spectrom; 1998; 12(20):1435-44. PubMed ID: 9796531
[TBL] [Abstract][Full Text] [Related]
37. Comparison of electrokinetics-based multidimensional separations coupled with electrospray ionization-tandem mass spectrometry for characterization of human salivary proteins.
Fang X; Yang L; Wang W; Song T; Lee CS; DeVoe DL; Balgley BM
Anal Chem; 2007 Aug; 79(15):5785-92. PubMed ID: 17614365
[TBL] [Abstract][Full Text] [Related]
38. Capillary electrophoresis-electrospray mass spectrometry for the analysis of recombinant bovine and porcine somatotropins.
Tsuji K; Baczynskyj L; Bronson GE
Anal Chem; 1992 Sep; 64(17):1864-70. PubMed ID: 1416039
[TBL] [Abstract][Full Text] [Related]
39. Use of capillary electrophoresis-electrospray ionization mass spectrometry in the analysis of synthetic peptides.
Rosnack KJ; Stroh JG; Singleton DH; Guarino BC; Andrews GC
J Chromatogr A; 1994 Jul; 675(1-2):219-25. PubMed ID: 8081459
[TBL] [Abstract][Full Text] [Related]
40. Capillary electrophoresis mass spectrometry and its application to the analysis of biological mixtures.
Moini M
Anal Bioanal Chem; 2002 Jul; 373(6):466-80. PubMed ID: 12172682
[TBL] [Abstract][Full Text] [Related]
[Previous] [Next] [New Search]