154 related articles for article (PubMed ID: 25938063)
1. Difference in normal corneal thickness and curvature between Mongolian and Han nationalities.
Zhao HX; Zhang L; Guan WY
Int J Ophthalmol; 2015; 8(2):399-402. PubMed ID: 25938063
[TBL] [Abstract][Full Text] [Related]
2. Central Corneal Thickness in Highly Myopic Eyes: Inter-device Agreement of Ultrasonic Pachymetry, Pentacam and Orbscan II Before and After Photorefractive Keratectomy.
Nassiri N; Sheibani K; Safi S; Nassiri S; Ziaei A; Haji F; Mehravaran S; Nassiri N
J Ophthalmic Vis Res; 2014 Jan; 9(1):14-21. PubMed ID: 24982727
[TBL] [Abstract][Full Text] [Related]
3. Measurement of central corneal thickness using Orbscan 3, Pentacam HR and ultrasound pachymetry in normal eyes.
Gharieb HM; Ashour DM; Saleh MI; Othman IS
Int Ophthalmol; 2020 Jul; 40(7):1759-1764. PubMed ID: 32221762
[TBL] [Abstract][Full Text] [Related]
4. Repeatability and agreement of CCT measurement in myopia using entacam and ultrasound pachymetry.
Luo YH; Zhong Q; Ouyang PB; Guo XJ; Duan XC
Int J Ophthalmol; 2012; 5(3):329-33. PubMed ID: 22773982
[TBL] [Abstract][Full Text] [Related]
5. Corneal thickness measurement using Orbscan, Pentacam, Galilei, and ultrasound in normal and post-femtosecond laser in situ keratomileusis eyes.
Park SH; Choi SK; Lee D; Jun EJ; Kim JH
Cornea; 2012 Sep; 31(9):978-82. PubMed ID: 22699561
[TBL] [Abstract][Full Text] [Related]
6. Average 3-dimensional models for the comparison of Orbscan II and Pentacam pachymetry maps in normal corneas.
Bourges JL; Alfonsi N; Laliberté JF; Chagnon M; Renard G; Legeais JM; Brunette I
Ophthalmology; 2009 Nov; 116(11):2064-71. PubMed ID: 19744719
[TBL] [Abstract][Full Text] [Related]
7. Measurement of Central Corneal Thickness Using Ultrasound Pachymetry and Orbscan II in Normal Eyes.
Sadoughi MM; Einollahi B; Einollahi N; Rezaei J; Roshandel D; Feizi S
J Ophthalmic Vis Res; 2015; 10(1):4-9. PubMed ID: 26005545
[TBL] [Abstract][Full Text] [Related]
8. Comparison of corneal measurements in keratoconic eyes using rotating Scheimpflug camera and scanning-slit topography.
Naderan M; Shoar S; Naderan M; Kamaleddin MA; Rajabi MT
Int J Ophthalmol; 2015; 8(2):275-80. PubMed ID: 25938040
[TBL] [Abstract][Full Text] [Related]
9. Comparison between Pentacam HR and Orbscan II after Hyperopic Photorefractive Keratectomy.
Jabbarvand M; Askarizadeh F; Sedaghat MR; Ghadimi H; Khosravi B; Amiri MA; Narooie-Noori F
J Ophthalmic Vis Res; 2017; 12(4):374-379. PubMed ID: 29090045
[TBL] [Abstract][Full Text] [Related]
10. Central corneal thickness measurement with Pentacam, Orbscan II, and ultrasound devices before and after laser refractive surgery for myopia.
Hashemi H; Mehravaran S
J Cataract Refract Surg; 2007 Oct; 33(10):1701-7. PubMed ID: 17889763
[TBL] [Abstract][Full Text] [Related]
11. Central Corneal Thickness Measurement Using Ultrasonic Pachymetry, Rotating Scheimpflug Camera, and Scanning-slit Topography Exclusively in Thin Non-keratoconic Corneas.
Mohammadpour M; Mohammad K; Karimi N
J Ophthalmic Vis Res; 2016; 11(3):245-51. PubMed ID: 27621779
[TBL] [Abstract][Full Text] [Related]
12. Comparison of central corneal thickness measurements by Pentacam, noncontact specular microscope, and ultrasound pachymetry in normal and post-LASIK eyes.
Al-Ageel S; Al-Muammar AM
Saudi J Ophthalmol; 2009 Oct; 23(3-4):181-7. PubMed ID: 23960858
[TBL] [Abstract][Full Text] [Related]
13. Topographic paracentral corneal thickness with pentacam and orbscan: effect of acoustic factor.
González-Pérez J; González-Méijome JM; Rodríguez Ares MT; Parafita MA
Eye Contact Lens; 2011 Nov; 37(6):348-53. PubMed ID: 21983548
[TBL] [Abstract][Full Text] [Related]
14. Comparison of corneal thickness measurements using ultrasound and Orbscan slit-scanning topography in normal and post-LASIK eyes.
Chakrabarti HS; Craig JP; Brahma A; Malik TY; McGhee CN
J Cataract Refract Surg; 2001 Nov; 27(11):1823-8. PubMed ID: 11709257
[TBL] [Abstract][Full Text] [Related]
15. Corneal thickness in keratoconus: comparing optical, ultrasound, and optical coherence tomography pachymetry.
Dutta D; Rao HL; Addepalli UK; Vaddavalli PK
Ophthalmology; 2013 Mar; 120(3):457-463. PubMed ID: 23177363
[TBL] [Abstract][Full Text] [Related]
16. Comparison of Central Corneal Thickness Measurements by Pentacam and Ultrasound Pachymetry in Normal Myopic Patients.
Emerah S; ELZakzouk E; Farag M
Electron Physician; 2016 Dec; 8(12):3441-3444. PubMed ID: 28163862
[TBL] [Abstract][Full Text] [Related]
17. An assessment of regional differences in corneal thickness in normal human eyes, using the Orbscan II or ultrasound pachymetry.
Doughty MJ; Jonuscheit S
Optometry; 2007 Apr; 78(4):181-90. PubMed ID: 17400140
[TBL] [Abstract][Full Text] [Related]
18. Central corneal thickness evaluation in healthy eyes with three different optical devices.
Lanza M; Paolillo E; Gironi Carnevale UA; Lanza A; Irregolare C; Mele L; Bifani M
Cont Lens Anterior Eye; 2015 Dec; 38(6):409-13. PubMed ID: 26048662
[TBL] [Abstract][Full Text] [Related]
19. Central and peripheral corneal thickness measurement in normal and keratoconic eyes using three corneal pachymeters.
Feizi S; Jafarinasab MR; Karimian F; Hasanpour H; Masudi A
J Ophthalmic Vis Res; 2014; 9(3):296-304. PubMed ID: 25667728
[TBL] [Abstract][Full Text] [Related]
20. Repeatability and Agreement of Orbscan II, Pentacam HR, and Galilei Tomography Systems in Corneas With Keratoconus.
Meyer JJ; Gokul A; Vellara HR; Prime Z; McGhee CN
Am J Ophthalmol; 2017 Mar; 175():122-128. PubMed ID: 27993593
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]