151 related articles for article (PubMed ID: 25944)
1. A comparative study of the electrode systems of three pH and blood gas apparatus. Winckers EK; Teunissen AJ; Van den Camp RA; Maas AH J Clin Chem Clin Biochem; 1978 Mar; 16(3):175-85. PubMed ID: 25944 [TBL] [Abstract][Full Text] [Related]
2. Carbon dioxide and oxygen partial pressure measurements in the cerebrospinal fluid in a conventional blood gas analyzer: analysis of bias and precision. Venkatesh B; Boots RJ J Neurol Sci; 1997 Mar; 147(1):5-8. PubMed ID: 9094053 [TBL] [Abstract][Full Text] [Related]
3. Use of carbon dioxide- and oxygen-tonometered phosphate-bicarbonate-chloride-glycerol-water mixtures for calibration and control of pH, pCO2, and pO2 electrode systems. Veefkind AH; Van den Camp RA; Maas AH Clin Chem; 1975 May; 21(6):685-93. PubMed ID: 235377 [TBL] [Abstract][Full Text] [Related]
4. Comparative study of automatic blood-gas analysers and their use in analysing arterial and capillary samples. Rubin P; Bradbury S; Prowse K Br Med J; 1979 Jan; 1(6157):156-8. PubMed ID: 33741 [TBL] [Abstract][Full Text] [Related]
5. Towards blood-gas autoanalysis an evaluation of the radiometer ABL. Selman BJ; Tait AR Br J Anaesth; 1976 May; 48(5):487-94. PubMed ID: 1276024 [TBL] [Abstract][Full Text] [Related]
6. Comparison of blood gas analyzer biases in measuring tonometered blood and a fluorocarbon-containing, proficiency-testing material. Hansen JE; Jensen RL; Casaburi R; Crapo RO Am Rev Respir Dis; 1989 Aug; 140(2):403-9. PubMed ID: 2504088 [TBL] [Abstract][Full Text] [Related]
7. Accuracy and precision of the portable StatPal II and the laboratory-based NOVA stat profile 1 for measurement of pH, P(CO2), and P(O2) in equine blood. Klein LV; Soma LR; Nann LE Vet Surg; 1999; 28(1):67-76. PubMed ID: 10025643 [TBL] [Abstract][Full Text] [Related]
9. Performance characteristics and interanalyzer variability of PO2 measurements using tonometered human blood. Scuderi PE; MacGregor DA; Bowton DL; Harris LC; Anderson R; James RL Am Rev Respir Dis; 1993 Jun; 147(6 Pt 1):1354-9. PubMed ID: 8503545 [TBL] [Abstract][Full Text] [Related]
10. Performance of a patient-dedicated, on-demand blood gas monitor in medical ICU patients. Mahutte CK; Sasse SA; Chen PA; Holody M Am J Respir Crit Care Med; 1994 Sep; 150(3):865-9. PubMed ID: 8087363 [TBL] [Abstract][Full Text] [Related]
11. An evaluation of the AVL 937C blood-gas and pH microanalyser. Soutter WP; Aitchison TC; Thorburn J; Sharp F Br J Anaesth; 1976 Dec; 48(12):1211-8. PubMed ID: 14657 [TBL] [Abstract][Full Text] [Related]
12. Testing of the AVL OPTI 1 portable blood gas analyzer during inflight conditions. Maillard D; Ferracci F; Marotte H; Canot S; Minh TT; Finetti P Aviat Space Environ Med; 1999 Apr; 70(4):346-50. PubMed ID: 10223272 [TBL] [Abstract][Full Text] [Related]
13. Evaluation of ampouled tonometered buffer solutions as a quality-control system for pH, pCO2, and pO2 measurement. Maas AH; Veefkind AH; Van den Camp RA; Teunissen AJ; Winckers EK; Jansen AP Clin Chem; 1977 Sep; 23(9):1718-25. PubMed ID: 19168 [TBL] [Abstract][Full Text] [Related]
14. Instrumental variability of respiratory blood gases among different blood gas analysers in different laboratories. Kampelmacher MJ; van Kesteren RG; Winckers EK Eur Respir J; 1997 Jun; 10(6):1341-4. PubMed ID: 9192940 [TBL] [Abstract][Full Text] [Related]
15. Blood gas analyses on equine blood: required correction factors [see comment]. Fedde MR Equine Vet J; 1991 Nov; 23(6):410-2. PubMed ID: 1778156 [TBL] [Abstract][Full Text] [Related]
16. A flexible and versatile program for blood-gas quality control. Elser RC; Sitler J; Garver C Am J Clin Pathol; 1982 Oct; 78(4):471-8. PubMed ID: 6814234 [TBL] [Abstract][Full Text] [Related]
17. A comparison of two methods of quality control of pH, Pco2, and Po2 measurements. Evans JR Ann Clin Biochem; 1978 May; 15(3):168-71. PubMed ID: 28069 [TBL] [Abstract][Full Text] [Related]
18. [Analytical reliability of the results of determining pH, pCO2 and pO2 with the ABL 300 (Radiometer) automatic pH and blood gas analyzer]. Tsachev K; Dochev D; Tikholov I Vutr Boles; 1988; 27(4):77-81. PubMed ID: 3145645 [TBL] [Abstract][Full Text] [Related]
19. Clinical performance of a blood gas monitor: a prospective, multicenter trial. Shapiro BA; Mahutte CK; Cane RD; Gilmour IJ Crit Care Med; 1993 Apr; 21(4):487-94. PubMed ID: 8472565 [TBL] [Abstract][Full Text] [Related]
20. [Analytical performances of the i-STAT portable clinical analyzer for the measurement of PO2 and PCO2]. Sachs C; Finetti P; Rabouine P; Abdoulaye F Ann Biol Clin (Paris); 2002; 60(4):411-20. PubMed ID: 12147445 [TBL] [Abstract][Full Text] [Related] [Next] [New Search]