These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.
167 related articles for article (PubMed ID: 25947080)
21. Reaction-Based Fluorescent Probes for the Imaging of Nitroxyl (HNO) in Biological Systems. Dong B; Kong X; Lin W ACS Chem Biol; 2018 Jul; 13(7):1714-1720. PubMed ID: 29210560 [TBL] [Abstract][Full Text] [Related]
23. Peculiarity in the electronic structure of Cu(II) complex ferromagnetically coupled with bisimino nitroxides. Ikoma T; Oshio H; Yamamoto M; Ohba Y; Nihei M J Phys Chem A; 2008 Sep; 112(37):8641-8. PubMed ID: 18714950 [TBL] [Abstract][Full Text] [Related]
24. Direct monitoring of formation and dissociation of individual metal complexes by single-molecule fluorescence spectroscopy. Kiel A; Kovacs J; Mokhir A; Krämer R; Herten DP Angew Chem Int Ed Engl; 2007; 46(18):3363-6. PubMed ID: 17397126 [No Abstract] [Full Text] [Related]
25. A BODIPY-based fluorescent chemodosimeter for Cu(II) driven by an oxidative dehydrogenation mechanism. Wang D; Shiraishi Y; Hirai T Chem Commun (Camb); 2011 Mar; 47(9):2673-5. PubMed ID: 21234464 [TBL] [Abstract][Full Text] [Related]
26. A FRET-based ratiometric fluorescent probe for nitroxyl detection in living cells. Zhang H; Liu R; Tan Y; Xie WH; Lei H; Cheung HY; Sun H ACS Appl Mater Interfaces; 2015 Mar; 7(9):5438-43. PubMed ID: 25658137 [TBL] [Abstract][Full Text] [Related]
27. Structure and magnetism of [M3](6/7+) metal chain complexes from density functional theory: analysis for copper and predictions for silver. Bénard M; Berry JF; Cotton FA; Gaudin C; López X; Murillo CA; Rohmer MM Inorg Chem; 2006 May; 45(10):3932-40. PubMed ID: 16676951 [TBL] [Abstract][Full Text] [Related]
28. Quantum dots as a possible oxygen sensor. Ziółczyk P; Kur-Kowalska K; Przybyt M; Miller E Spectrochim Acta A Mol Biomol Spectrosc; 2014 May; 126():28-35. PubMed ID: 24568848 [TBL] [Abstract][Full Text] [Related]
29. Ratiometric displacement approach to Cu(II) sensing by fluorescence. Royzen M; Dai Z; Canary JW J Am Chem Soc; 2005 Feb; 127(6):1612-3. PubMed ID: 15700975 [TBL] [Abstract][Full Text] [Related]
30. A reductant-resistant and metal-free fluorescent probe for nitroxyl applicable to living cells. Kawai K; Ieda N; Aizawa K; Suzuki T; Miyata N; Nakagawa H J Am Chem Soc; 2013 Aug; 135(34):12690-6. PubMed ID: 23865676 [TBL] [Abstract][Full Text] [Related]
31. A near-infrared fluorescent probe for the selective detection of HNO in living cells and in vivo. Liu P; Jing X; Yu F; Lv C; Chen L Analyst; 2015 Jul; 140(13):4576-83. PubMed ID: 25997397 [TBL] [Abstract][Full Text] [Related]
32. NitroxylFluor: A Thiol-Based Fluorescent Probe for Live-Cell Imaging of Nitroxyl. Pino NW; Davis J; Yu Z; Chan J J Am Chem Soc; 2017 Dec; 139(51):18476-18479. PubMed ID: 29239609 [TBL] [Abstract][Full Text] [Related]
33. A near-infrared fluorescence turn-on sensor for sulfide anions. Cao X; Lin W; He L Org Lett; 2011 Sep; 13(17):4716-9. PubMed ID: 21809838 [TBL] [Abstract][Full Text] [Related]
34. A highly sensitive and reductant-resistant fluorescent probe for nitroxyl in aqueous solution and serum. Mao GJ; Zhang XB; Shi XL; Liu HW; Wu YX; Zhou LY; Tan W; Yu RQ Chem Commun (Camb); 2014 Jun; 50(43):5790-2. PubMed ID: 24756360 [TBL] [Abstract][Full Text] [Related]
35. Role of fluorophore-metal interaction in photoinduced electron transfer (PET) sensors: time-dependent density functional theory (TDDFT) study. Lee H; Hancock RD; Lee HS J Phys Chem A; 2013 Dec; 117(50):13345-55. PubMed ID: 24099321 [TBL] [Abstract][Full Text] [Related]
36. A coumarin-derived fluorescent chemosensor for selectively detecting Cu²⁺: synthesis, DFT calculations and cell imaging applications. Chen F; Liu G; Shi Y; Xi P; Cheng J; Hong J; Shen R; Yao X; Bai D; Zeng Z Talanta; 2014 Jun; 124():139-45. PubMed ID: 24767455 [TBL] [Abstract][Full Text] [Related]
37. Visible-near-infrared and fluorescent copper sensors based on julolidine conjugates: selective detection and fluorescence imaging in living cells. Maity D; Manna AK; Karthigeyan D; Kundu TK; Pati SK; Govindaraju T Chemistry; 2011 Sep; 17(40):11152-61. PubMed ID: 21882277 [TBL] [Abstract][Full Text] [Related]
38. Xerogel optical sensor films for quantitative detection of nitroxyl. Dobmeier KP; Riccio DA; Schoenfisch MH Anal Chem; 2008 Feb; 80(4):1247-54. PubMed ID: 18197695 [TBL] [Abstract][Full Text] [Related]
39. Rational design of Near-Infrared fluorescent probe for monitoring HNO in plants. Luo F; Zhang Y; Zhang S; Ji Y; Yan D; Lai M; Yang X; Zhang D; Ji X Spectrochim Acta A Mol Biomol Spectrosc; 2024 Nov; 321():124672. PubMed ID: 38905899 [TBL] [Abstract][Full Text] [Related]
40. An iminocoumarin-Cu(II) ensemble-based chemodosimeter toward thiols. Jung HS; Han JH; Habata Y; Kang C; Kim JS Chem Commun (Camb); 2011 May; 47(18):5142-4. PubMed ID: 21409269 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]