These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

222 related articles for article (PubMed ID: 25955582)

  • 1. Theoretical Investigation of Random Noise-Limited Signal-to-Noise Ratio in MR-Based Electrical Properties Tomography.
    Lee SK; Bulumulla S; Hancu I
    IEEE Trans Med Imaging; 2015 Nov; 34(11):2220-32. PubMed ID: 25955582
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Numerical Experiments on the Contrast Capability of Magnetic Resonance Electrical Property Tomography.
    Duan S; Zhu Y; Liu F; Xin SX
    Magn Reson Med Sci; 2020 Feb; 19(1):77-85. PubMed ID: 31019159
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Magnetic resonance electrical properties tomography for small anomalies using boundary conditions: A simulation study.
    Lee J; Choi N; Seo JK; Kim DH
    Med Phys; 2017 Sep; 44(9):4773-4785. PubMed ID: 28508476
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Signal-to-noise ratio and MR tissue parameters in human brain imaging at 3, 7, and 9.4 tesla using current receive coil arrays.
    Pohmann R; Speck O; Scheffler K
    Magn Reson Med; 2016 Feb; 75(2):801-9. PubMed ID: 25820458
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Convection-reaction equation based magnetic resonance electrical properties tomography (cr-MREPT).
    Hafalir FS; Oran OF; Gurler N; Ider YZ
    IEEE Trans Med Imaging; 2014 Mar; 33(3):777-93. PubMed ID: 24595349
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Increasing the signal-to-noise ratio by using vertically stacked phased array coils for low-field magnetic resonance imaging.
    Liang D; Hui HT; Yeo TS
    IEEE Trans Inf Technol Biomed; 2012 Nov; 16(6):1150-6. PubMed ID: 22575694
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Error analysis of helmholtz-based MR-electrical properties tomography.
    Mandija S; Sbrizzi A; Katscher U; Luijten PR; van den Berg CAT
    Magn Reson Med; 2018 Jul; 80(1):90-100. PubMed ID: 29144031
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Electrical properties tomography in the human brain at 1.5, 3, and 7T: a comparison study.
    van Lier AL; Raaijmakers A; Voigt T; Lagendijk JJ; Luijten PR; Katscher U; van den Berg CA
    Magn Reson Med; 2014 Jan; 71(1):354-63. PubMed ID: 23401276
    [TBL] [Abstract][Full Text] [Related]  

  • 9. 2D Magnetic resonance electrical property tomography based on B1(-) field mapping.
    Yuqing Wan ; Negishi M; Constable RT
    Annu Int Conf IEEE Eng Med Biol Soc; 2014; 2014():6060-3. PubMed ID: 25571379
    [TBL] [Abstract][Full Text] [Related]  

  • 10. CONtrast Conformed Electrical Properties Tomography (CONCEPT) Based on Multi- Channel Transmission and Alternating Direction Method of Multipliers.
    Wang Y; Van De Moortele PF; He B
    IEEE Trans Med Imaging; 2019 Feb; 38(2):349-359. PubMed ID: 30106715
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Assessment of averaging spatially correlated noise for 3-D radial imaging.
    Stobbe RW; Beaulieu C
    IEEE Trans Med Imaging; 2011 Jul; 30(7):1381-90. PubMed ID: 21335306
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Statistical analysis of the accuracy of water content-based electrical properties tomography.
    Han J; Gao Y; Nan X; Liu F; Xin SX
    NMR Biomed; 2020 May; 33(5):e4273. PubMed ID: 32048385
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Use of dielectric padding to eliminate low convective field artifact in cr-MREPT conductivity images.
    Yildiz G; Ider YZ
    Magn Reson Med; 2019 May; 81(5):3168-3184. PubMed ID: 30693565
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Gradient-based electrical properties tomography (gEPT): A robust method for mapping electrical properties of biological tissues in vivo using magnetic resonance imaging.
    Liu J; Zhang X; Schmitter S; Van de Moortele PF; He B
    Magn Reson Med; 2015 Sep; 74(3):634-46. PubMed ID: 25213371
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bias correction for phase-based cr-MREPT using low resolution B1+ magnitude.
    Çan MK; Ider YZ
    Phys Med Biol; 2024 Jun; 69(12):. PubMed ID: 38830364
    [No Abstract]   [Full Text] [Related]  

  • 16. Theoretical signal-to-noise ratio and spatial resolution dependence on the magnetic field strength for hyperpolarized noble gas magnetic resonance imaging of human lungs.
    Parra-Robles J; Cross AR; Santyr GE
    Med Phys; 2005 Jan; 32(1):221-9. PubMed ID: 15719973
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Divergence-Based Magnetic Resonance Electrical Properties Tomography.
    Liu C; Guo L; Li M; Chen H; Jin J; Chen W; Liu F; Crozier S
    IEEE Trans Biomed Eng; 2021 Jan; 68(1):192-203. PubMed ID: 32746031
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Error analysis of nonconstant admittivity for MR-based electric property imaging.
    Seo JK; Kim MO; Lee J; Choi N; Woo EJ; Kim HJ; Kwon OI; Kim DH
    IEEE Trans Med Imaging; 2012 Feb; 31(2):430-7. PubMed ID: 21990329
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Simultaneous Quantitative Imaging of Electrical Properties and Proton Density From B
    Jiaen Liu ; Van de Moortele PF; Xiaotong Zhang ; Yicun Wang ; Bin He
    IEEE Trans Med Imaging; 2016 Sep; 35(9):2064-2073. PubMed ID: 28005010
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Magnetic field strength dependent SNR gain at the center of a spherical phantom and up to 11.7T.
    Le Ster C; Grant A; Van de Moortele PF; Monreal-Madrigal A; Adriany G; Vignaud A; Mauconduit F; Rabrait-Lerman C; Poser BA; Uğurbil K; Boulant N
    Magn Reson Med; 2022 Nov; 88(5):2131-2138. PubMed ID: 35849739
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]