BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 25958301)

  • 1. Negative and positive temperature dependence of potassium leak in MscS mutants: Implications for understanding thermosensitive channels.
    Koprowski P; Sliwinska MA; Kubalski A
    Biochim Biophys Acta; 2015 Aug; 1848(8):1678-86. PubMed ID: 25958301
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Genetic screen for potassium leaky small mechanosensitive channels (MscS) in Escherichia coli: recognition of cytoplasmic β domain as a new gating element.
    Koprowski P; Grajkowski W; Isacoff EY; Kubalski A
    J Biol Chem; 2011 Jan; 286(1):877-88. PubMed ID: 20978126
    [TBL] [Abstract][Full Text] [Related]  

  • 3. The cytoplasmic cage domain of the mechanosensitive channel MscS is a sensor of macromolecular crowding.
    Rowe I; Anishkin A; Kamaraju K; Yoshimura K; Sukharev S
    J Gen Physiol; 2014 May; 143(5):543-57. PubMed ID: 24778428
    [TBL] [Abstract][Full Text] [Related]  

  • 4. The mechanosensitive channel of small conductance (MscS) functions as a Jack-in-the box.
    Malcolm HR; Blount P; Maurer JA
    Biochim Biophys Acta; 2015 Jan; 1848(1 Pt A):159-66. PubMed ID: 25450806
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Gating and inactivation of mechanosensitive channels of small conductance: A continuum mechanics study.
    Zhu L; Cui Q; Xiao H; Liao X; Chen X
    J Mech Behav Biomed Mater; 2019 Feb; 90():502-514. PubMed ID: 30453114
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Mutations in a Conserved Domain of E. coli MscS to the Most Conserved Superfamily Residue Leads to Kinetic Changes.
    Malcolm HR; Blount P
    PLoS One; 2015; 10(9):e0136756. PubMed ID: 26340270
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Crystal structure of Escherichia coli MscS, a voltage-modulated and mechanosensitive channel.
    Bass RB; Strop P; Barclay M; Rees DC
    Science; 2002 Nov; 298(5598):1582-7. PubMed ID: 12446901
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Characterization of the resting MscS: modeling and analysis of the closed bacterial mechanosensitive channel of small conductance.
    Anishkin A; Akitake B; Sukharev S
    Biophys J; 2008 Feb; 94(4):1252-66. PubMed ID: 17981908
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Adaptive behavior of bacterial mechanosensitive channels is coupled to membrane mechanics.
    Belyy V; Kamaraju K; Akitake B; Anishkin A; Sukharev S
    J Gen Physiol; 2010 Jun; 135(6):641-52. PubMed ID: 20513760
    [TBL] [Abstract][Full Text] [Related]  

  • 10. The pathway and spatial scale for MscS inactivation.
    Kamaraju K; Belyy V; Rowe I; Anishkin A; Sukharev S
    J Gen Physiol; 2011 Jul; 138(1):49-57. PubMed ID: 21670207
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Selectivity mechanism of the mechanosensitive channel MscS revealed by probing channel subconducting states.
    Cox CD; Nomura T; Ziegler CS; Campbell AK; Wann KT; Martinac B
    Nat Commun; 2013; 4():2137. PubMed ID: 23842527
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Identification of mutations that alter the gating of the Escherichia coli mechanosensitive channel protein, MscK.
    Li C; Edwards MD; Jeong H; Roth J; Booth IR
    Mol Microbiol; 2007 Apr; 64(2):560-74. PubMed ID: 17493135
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Cytoplasmic Domain of MscS Interacts with Cell Division Protein FtsZ: A Possible Non-Channel Function of the Mechanosensitive Channel in Escherichia Coli.
    Koprowski P; Grajkowski W; Balcerzak M; Filipiuk I; Fabczak H; Kubalski A
    PLoS One; 2015; 10(5):e0127029. PubMed ID: 25996836
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Ionic regulation of MscK, a mechanosensitive channel from Escherichia coli.
    Li Y; Moe PC; Chandrasekaran S; Booth IR; Blount P
    EMBO J; 2002 Oct; 21(20):5323-30. PubMed ID: 12374733
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Lipid-protein interaction of the MscS mechanosensitive channel examined by scanning mutagenesis.
    Nomura T; Sokabe M; Yoshimura K
    Biophys J; 2006 Oct; 91(8):2874-81. PubMed ID: 16861270
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Pivotal role of the glycine-rich TM3 helix in gating the MscS mechanosensitive channel.
    Edwards MD; Li Y; Kim S; Miller S; Bartlett W; Black S; Dennison S; Iscla I; Blount P; Bowie JU; Booth IR
    Nat Struct Mol Biol; 2005 Feb; 12(2):113-9. PubMed ID: 15665866
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Voltage-Dependent Inactivation of MscS Occurs Independently of the Positively Charged Residues in the Transmembrane Domain.
    Nomura T; Sokabe M; Yoshimura K
    Biomed Res Int; 2016; 2016():2401657. PubMed ID: 28101504
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Visualization of the mechanosensitive ion channel MscS under membrane tension.
    Zhang Y; Daday C; Gu RX; Cox CD; Martinac B; de Groot BL; Walz T
    Nature; 2021 Feb; 590(7846):509-514. PubMed ID: 33568813
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Gain-of-function mutations reveal expanded intermediate states and a sequential action of two gates in MscL.
    Anishkin A; Chiang CS; Sukharev S
    J Gen Physiol; 2005 Feb; 125(2):155-70. PubMed ID: 15684093
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Voltage-dependent hydration and conduction properties of the hydrophobic pore of the mechanosensitive channel of small conductance.
    Spronk SA; Elmore DE; Dougherty DA
    Biophys J; 2006 May; 90(10):3555-69. PubMed ID: 16500980
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.