These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

138 related articles for article (PubMed ID: 25959048)

  • 1. Continuous minimally invasive cardiac output monitoring with the COstatus in a neonatal swine model: recalibration is necessary during vasoconstriction and vasodilation.
    Cisternas AF; Martin-Flores M; Gleed RD
    Paediatr Anaesth; 2015 Aug; 25(8):852-859. PubMed ID: 25959048
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Comparison of Transpulmonary Thermodilution and Calibrated Pulse Contour Analysis with Pulmonary Artery Thermodilution Cardiac Output Measurements in Anesthetized Dogs.
    Garofalo NA; Teixeira-Neto FJ; Rodrigues JC; Cerejo SA; Aguiar AJ; Becerra-Velásquez DR
    J Vet Intern Med; 2016 Jul; 30(4):941-50. PubMed ID: 27237065
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Calibrated versus uncalibrated arterial pressure waveform analysis in monitoring cardiac output with transpulmonary thermodilution in patients with severe sepsis and septic shock: an observational study.
    Slagt C; Helmi M; Malagon I; Groeneveld AB
    Eur J Anaesthesiol; 2015 Jan; 32(1):5-12. PubMed ID: 25387298
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Estimated continuous cardiac output based on pulse wave transit time in off-pump coronary artery bypass grafting: a comparison with transpulmonary thermodilution.
    Smetkin AA; Hussain A; Fot EV; Zakharov VI; Izotova NN; Yudina AS; Dityateva ZA; Gromova YV; Kuzkov VV; Bjertnæs LJ; Kirov MY
    J Clin Monit Comput; 2017 Apr; 31(2):361-370. PubMed ID: 26951494
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Validation of an ultrasound dilution technology for cardiac output measurement and shunt detection in infants and children.
    Lindberg L; Johansson S; Perez-de-Sa V
    Pediatr Crit Care Med; 2014 Feb; 15(2):139-47. PubMed ID: 24366506
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Multicenter study verifying a method of noninvasive continuous cardiac output measurement using pulse wave transit time: a comparison with intermittent bolus thermodilution cardiac output.
    Yamada T; Tsutsui M; Sugo Y; Sato T; Akazawa T; Sato N; Yamashita K; Ishihara H; Takeda J
    Anesth Analg; 2012 Jul; 115(1):82-7. PubMed ID: 22467885
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Influence of lung injury on cardiac output measurement using transpulmonary ultrasound dilution: a validation study in neonatal lambs.
    Vrancken SL; de Boode WP; Hopman JC; Looijen-Salamon MG; Liem KD; van Heijst AF
    Br J Anaesth; 2012 Dec; 109(6):870-8. PubMed ID: 22907338
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The reliability of pulse contour-derived cardiac output during hemorrhage and after vasopressor administration.
    Bein B; Meybohm P; Cavus E; Renner J; Tonner PH; Steinfath M; Scholz J; Doerges V
    Anesth Analg; 2007 Jul; 105(1):107-13. PubMed ID: 17578965
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Ultrasound dilution: an accurate means of determining cardiac output in children.
    Crittendon I; Dreyer WJ; Decker JA; Kim JJ
    Pediatr Crit Care Med; 2012 Jan; 13(1):42-6. PubMed ID: 21499176
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Reliability of continuous cardiac output measurement during intra-abdominal hypertension relies on repeated calibrations: an experimental animal study.
    Gruenewald M; Renner J; Meybohm P; Höcker J; Scholz J; Bein B
    Crit Care; 2008; 12(5):R132. PubMed ID: 18957114
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Cardiac output measurement using an ultrasound dilution method: a validation study in ventilated piglets.
    de Boode WP; van Heijst AF; Hopman JC; Tanke RB; van der Hoeven HG; Liem KD
    Pediatr Crit Care Med; 2010 Jan; 11(1):103-8. PubMed ID: 19593242
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Cardiac output determination from the arterial pressure wave: clinical testing of a novel algorithm that does not require calibration.
    Manecke GR; Auger WR
    J Cardiothorac Vasc Anesth; 2007 Feb; 21(1):3-7. PubMed ID: 17289472
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Assessment of cardiac output measurement in dogs by transpulmonary pulse contour analysis.
    Shih A; Maisenbacher HW; Bandt C; Ricco C; Bailey J; Rivera J; Estrada A
    J Vet Emerg Crit Care (San Antonio); 2011 Aug; 21(4):321-7. PubMed ID: 21827589
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Evaluation of transpulmonary ultrasound dilution cardiac output in piglets: accuracy, precision and trending ability with room temperature injectate.
    Hon S; Martin-Flores M; Koehler P; Gleed R; Campoy L
    Vet Anaesth Analg; 2023 Mar; 50(2):163-169. PubMed ID: 36641330
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Cardiac output measurement with transpulmonary ultrasound dilution is feasible in the presence of a left-to-right shunt: a validation study in lambs.
    Vrancken SL; de Boode WP; Hopman JC; Singh SK; Liem KD; van Heijst AF
    Br J Anaesth; 2012 Mar; 108(3):409-16. PubMed ID: 22171359
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Continuous cardiac output monitoring via arterial pressure waveform analysis following severe hemorrhagic shock in dogs.
    Cooper ES; Muir WW
    Crit Care Med; 2007 Jul; 35(7):1724-9. PubMed ID: 17452933
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Comparison of arterial pressure waveform analysis with the lithium dilution technique to monitor cardiac output in anesthetized dogs.
    Chen HC; Sinclair MD; Dyson DH; McDonell WN; Sears WC
    Am J Vet Res; 2005 Aug; 66(8):1430-6. PubMed ID: 16173489
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Comparison of the ability of two continuous cardiac output monitors to measure trends in cardiac output: estimated continuous cardiac output measured by modified pulse wave transit time and an arterial pulse contour-based cardiac output device.
    Terada T; Oiwa A; Maemura Y; Robert S; Kessoku S; Ochiai R
    J Clin Monit Comput; 2016 Oct; 30(5):621-7. PubMed ID: 26370094
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Uncalibrated arterial pulse contour analysis versus continuous thermodilution technique: effects of alterations in arterial waveform.
    Lorsomradee S; Lorsomradee S; Cromheecke S; De Hert SG
    J Cardiothorac Vasc Anesth; 2007 Oct; 21(5):636-43. PubMed ID: 17905266
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Lithium dilution measurement of cardiac output and arterial pulse waveform analysis: an indicator dilution calibrated beat-by-beat system for continuous estimation of cardiac output.
    Jonas MM; Tanser SJ
    Curr Opin Crit Care; 2002 Jun; 8(3):257-61. PubMed ID: 12386506
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.