These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

147 related articles for article (PubMed ID: 25962864)

  • 1. Non-invasive volumetric assessment of aortic atheroma: a core laboratory validation using computed tomography angiography.
    Hammadah M; Qintar M; Nissen SE; John JS; Alkharabsheh S; Mobolaji-Lawal M; Philip F; Uno K; Kataoka Y; Babb B; Poliszczuk R; Kapadia SR; Tuzcu EM; Schoenhagen P; Nicholls SJ; Puri R
    Int J Cardiovasc Imaging; 2016 Jan; 32(1):121-9. PubMed ID: 25962864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. The Extent of Aortic Atherosclerosis Predicts the Occurrence, Severity, and Recovery of Acute Kidney Injury After Transcatheter Aortic Valve Replacement.
    Shishikura D; Kataoka Y; Pisaniello AD; Delacroix S; Montarello JK; Nicholls SJ; Worthley SG
    Circ Cardiovasc Interv; 2018 Aug; 11(8):e006367. PubMed ID: 30354779
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Total coronary atherosclerotic plaque burden assessment by CT angiography for detecting obstructive coronary artery disease associated with myocardial perfusion abnormalities.
    Kishi S; Magalhães TA; Cerci RJ; Matheson MB; Vavere A; Tanami Y; Kitslaar PH; George RT; Brinker J; Miller JM; Clouse ME; Lemos PA; Niinuma H; Reiber JH; Rochitte CE; Rybicki FJ; Di Carli MF; Cox C; Lima JA; Arbab-Zadeh A
    J Cardiovasc Comput Tomogr; 2016; 10(2):121-7. PubMed ID: 26817414
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Automated 3-dimensional aortic annular assessment by multidetector computed tomography in transcatheter aortic valve implantation.
    Watanabe Y; Morice MC; Bouvier E; Leong T; Hayashida K; Lefèvre T; Hovasse T; Romano M; Chevalier B; Donzeau-Gouge P; Farge A; Cormier B; Garot P
    JACC Cardiovasc Interv; 2013 Sep; 6(9):955-64. PubMed ID: 23954060
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Aortic atheroma burden predicts acute cerebrovascular events after transcatheter aortic valve implantation: insights from volumetric multislice computed tomography analysis.
    Kataoka Y; Puri R; Pisaniello AD; Hammadah M; Qintar M; Uno K; Montarello JK; Nicholls SJ; Worthley SG
    EuroIntervention; 2016 Aug; 12(6):783-9. PubMed ID: 27542792
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Extent of thoracic aortic atheroma burden and long-term mortality after cardiothoracic surgery: a computed tomography study.
    Kurra V; Lieber ML; Sola S; Kalahasti V; Hammer D; Gimple S; Flamm SD; Bolen MA; Halliburton SS; Mihaljevic T; Desai MY; Schoenhagen P
    JACC Cardiovasc Imaging; 2010 Oct; 3(10):1020-9. PubMed ID: 20947047
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Accuracy and reproducibility of aortic annulus sizing using a dedicated three-dimensional computed tomography reconstruction tool in patients evaluated for transcatheter aortic valve replacement.
    Stortecky S; Heg D; Gloekler S; Wenaweser P; Windecker S; Buellesfeld L
    EuroIntervention; 2014 Jul; 10(3):339-46. PubMed ID: 24273249
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Three-dimensional quantification and visualization of aortic calcification by multidetector-row computed tomography: a simple approach using a volume-rendering method.
    Mori S; Takaya T; Kinugasa M; Ito T; Takamine S; Fujiwara S; Nishii T; Kono AK; Inoue T; Satomi-Kobayashi S; Rikitake Y; Okita Y; Hirata K
    Atherosclerosis; 2015 Apr; 239(2):622-8. PubMed ID: 25554696
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Preoperative multidetector computed tomograpy angiography for planning of minimally invasive robotic mitral valve surgery: impact on decision making.
    Moodley S; Schoenhagen P; Gillinov AM; Mihaljevic T; Flamm SD; Griffin BP; Desai MY
    J Thorac Cardiovasc Surg; 2013 Aug; 146(2):262-8.e1. PubMed ID: 22841167
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Influence of computed tomography angiography reconstruction software on anatomic measurements and endograft component selection for endovascular abdominal aortic aneurysm repair.
    Corriere MA; Islam A; Craven TE; Conlee TD; Hurie JB; Edwards MS
    J Vasc Surg; 2014 May; 59(5):1224-31.e1-3. PubMed ID: 24439321
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Validation of coronary computed tomography angiography scores for non-invasive assessment of atherosclerotic burden through a comparison with multivessel intravascular ultrasound.
    Cavalcante R; Bittencourt MS; Pinheiro TL; Falcao BA; Morais GR; Soares P; Mariani J; Ribeiro E; Kalil-Filho R; Rochitte CE; Lemos PA
    Atherosclerosis; 2016 Apr; 247():21-7. PubMed ID: 26854972
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Reproducibility of deriving parameters of AAA rupture risk from patient-specific 3D finite element models.
    Hyhlik-Dürr A; Krieger T; Geisbüsch P; Kotelis D; Able T; Böckler D
    J Endovasc Ther; 2011 Jun; 18(3):289-98. PubMed ID: 21679063
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Thoracic Aortic Strain is Irrelevant Regarding Endograft Sizing in Most Young Patients.
    Csobay-Novák C; Fontanini DM; Szilágyi B; Szeberin Z; Kolossváry M; Maurovich-Horvat P; Hüttl K; Sótonyi P
    Ann Vasc Surg; 2017 Jan; 38():227-232. PubMed ID: 27522983
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Prospective validation of standardized, 3-dimensional, quantitative coronary computed tomographic plaque measurements using radiofrequency backscatter intravascular ultrasound as reference standard in intermediate coronary arterial lesions: results from the ATLANTA (assessment of tissue characteristics, lesion morphology, and hemodynamics by angiography with fractional flow reserve, intravascular ultrasound and virtual histology, and noninvasive computed tomography in atherosclerotic plaques) I study.
    Voros S; Rinehart S; Qian Z; Vazquez G; Anderson H; Murrieta L; Wilmer C; Carlson H; Taylor K; Ballard W; Karmpaliotis D; Kalynych A; Brown C
    JACC Cardiovasc Interv; 2011 Feb; 4(2):198-208. PubMed ID: 21349459
    [TBL] [Abstract][Full Text] [Related]  

  • 15. ECG-triggered high-pitch CT for simultaneous assessment of the aorta and coronary arteries.
    Hachulla AL; Ronot M; Noble S; Becker CD; Montet X; Vallée JP
    J Cardiovasc Comput Tomogr; 2016; 10(5):407-13. PubMed ID: 27451049
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Reproducibility of semi-automatic coronary plaque quantification in coronary CT angiography with sub-mSv radiation dose.
    Øvrehus KA; Schuhbaeck A; Marwan M; Achenbach S; Nørgaard BL; Bøtker HE; Dey D
    J Cardiovasc Comput Tomogr; 2016; 10(2):114-20. PubMed ID: 26712694
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Standardized Protocol to Analyze Computed Tomography Imaging of Type B Aortic Dissections.
    Kamman AV; van Herwaarden JA; Orrico M; Nauta FJ; Heijmen RH; Moll FL; Trimarchi S
    J Endovasc Ther; 2016 Jun; 23(3):472-82. PubMed ID: 27090166
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Automatic detection of aorto-femoral vessel trajectory from whole-body computed tomography angiography data sets.
    Gao X; Kitslaar PH; Budde RP; Tu S; de Graaf MA; Xu L; Xu B; Scholte AJ; Dijkstra J; Reiber JH
    Int J Cardiovasc Imaging; 2016 Aug; 32(8):1311-22. PubMed ID: 27209285
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Validation of pre-procedural aortic aneurysm volume calculations to estimate procedural fill volume of endobags in endovascular aortic sealing.
    Boersen JT; van den Ham LH; Heyligers JM; Vahl AC; Vriens PW; Reijnen MM; de Vries JP
    J Cardiovasc Surg (Torino); 2017 Oct; 58(5):674-679. PubMed ID: 26173392
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Measurement of maximum diameter of native abdominal aortic aneurysm by angio-CT: reproducibility is better with the semi-automated method.
    Mora C; Marcus C; Barbe C; Ecarnot F; Long A
    Eur J Vasc Endovasc Surg; 2014 Feb; 47(2):139-50. PubMed ID: 24268793
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.