BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

121 related articles for article (PubMed ID: 25964710)

  • 1. Context-specific method for detection of soft-tissue lesions in non-cathartic low-dose dual-energy CT colonography.
    Näppi JJ; Regge D; Yoshida H
    Proc SPIE Int Soc Opt Eng; 2015 Mar; 9414():94142Y. PubMed ID: 25964710
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Computer-Aided Detection of Colorectal Lesions with Super-Resolution CT Colonography: Pilot Evaluation.
    Näppi JJ; Do S; Yoshida H
    Abdom Imaging (2013); 2013; 8198():73-80. PubMed ID: 25580475
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Information-Preserving Pseudo-Enhancement Correction for Non-Cathartic Low-Dose Dual-Energy CT Colonography.
    Näppi JJ; Tachibana R; Regge D; Yoshida H
    Abdom Imaging (2014); 2014 Sep; 8676():159-168. PubMed ID: 26236780
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Electronic cleansing for dual-energy CT colonography based on material decomposition and virtual monochromatic imaging.
    Tachibana R; Näppi JJ; Kim SH; Yoshida H
    Proc SPIE Int Soc Opt Eng; 2015 Mar; 9414():94140Q. PubMed ID: 25844029
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Structure-analysis method for electronic cleansing in cathartic and noncathartic CT colonography.
    Cai W; Zalis ME; Näppi J; Harris GJ; Yoshida H
    Med Phys; 2008 Jul; 35(7):3259-77. PubMed ID: 18697551
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Volumetric detection of colorectal lesions for noncathartic dual-energy computed tomographic colonography.
    Näppi JJ; Kim SH; Yoshida H
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():3740-3. PubMed ID: 23366741
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Nonlinear regression-based method for pseudoenhancement correction in CT colonography.
    Tsagaan B; Näppi J; Yoshida H
    Med Phys; 2009 Aug; 36(8):3596-606. PubMed ID: 19746794
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Virtual colon tagging for electronic cleansing in dual-energy fecal-tagging CT colonography.
    Cai W; Kim SH; Lee JG; Yoshida H
    Annu Int Conf IEEE Eng Med Biol Soc; 2012; 2012():3736-9. PubMed ID: 23366740
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Application of Pseudo-enhancement Correction to Virtual Monochromatic CT Colonography.
    Tachibana R; Näppi JJ; Yoshida H
    Abdom Imaging (2014); 2014 Sep; 8676():169-178. PubMed ID: 26236781
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Electronic cleansing in fecal-tagging dual-energy CT colonography based on material decomposition and virtual colon tagging.
    Cai W; Lee JG; Zhang D; Kim SH; Zalis M; Yoshida H
    IEEE Trans Biomed Eng; 2015 Feb; 62(2):754-65. PubMed ID: 25350911
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Computed tomographic colonography without cathartic preparation for the detection of colorectal polyps.
    Iannaccone R; Laghi A; Catalano C; Mangiapane F; Lamazza A; Schillaci A; Sinibaldi G; Murakami T; Sammartino P; Hori M; Piacentini F; Nofroni I; Stipa V; Passariello R
    Gastroenterology; 2004 Nov; 127(5):1300-11. PubMed ID: 15520999
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Dual-energy index value of luminal air in fecal-tagging computed tomography colonography: findings and impact on electronic cleansing.
    Cai W; Zhang D; Lee JG; Shirai Y; Kim SH; Yoshida H
    J Comput Assist Tomogr; 2013; 37(2):183-94. PubMed ID: 23493207
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Full-laxative versus minimum-laxative fecal-tagging CT colonography using 64-detector row CT: prospective blinded comparison of diagnostic performance, tagging quality, and patient acceptance.
    Nagata K; Okawa T; Honma A; Endo S; Kudo SE; Yoshida H
    Acad Radiol; 2009 Jul; 16(7):780-9. PubMed ID: 19375954
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Informatics in radiology: dual-energy electronic cleansing for fecal-tagging CT colonography.
    Cai W; Kim SH; Lee JG; Yoshida H
    Radiographics; 2013 May; 33(3):891-912. PubMed ID: 23479680
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Computerized detection of colorectal masses in CT colonography based on fuzzy merging and wall-thickening analysis.
    Näppi JJ; Frimmel H; Dachman AH; Yoshida H
    Med Phys; 2004 Apr; 31(4):860-72. PubMed ID: 15125004
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Dual-energy computed tomography colonography using dual-layer spectral detector computed tomography: Utility of virtual monochromatic imaging for electronic cleansing.
    Taguchi N; Oda S; Imuta M; Yamamura S; Yokota Y; Nakaura T; Nagayama Y; Kidoh M; Utsunomiya D; Funama Y; Baba H; Yamashita Y
    Eur J Radiol; 2018 Nov; 108():7-12. PubMed ID: 30396674
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Fecal-tagging CT colonography with structure-analysis electronic cleansing for detection of colorectal flat lesions.
    Xu Y; Cai W; Nappi J; Yoshida H
    Eur J Radiol; 2012 Aug; 81(8):1712-6. PubMed ID: 21596500
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Sub-millisievert CT colonography: effect of knowledge-based iterative reconstruction on the detection of colonic polyps.
    Kang HJ; Kim SH; Shin CI; Joo I; Ryu H; Kim SG; Im JP; Han JK
    Eur Radiol; 2018 Dec; 28(12):5258-5266. PubMed ID: 29948063
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Computer-aided detection in computed tomography colonography with full fecal tagging: comparison of standalone performance of 3 automated polyp detection systems.
    Hein PA; Krug LD; Romano VC; Kandel S; Hamm B; Rogalla P
    Can Assoc Radiol J; 2010 Apr; 61(2):102-8. PubMed ID: 20004546
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Errors in CT colonography.
    Trilisky I; Ward E; Dachman AH
    Abdom Imaging; 2015 Oct; 40(7):2099-111. PubMed ID: 26164603
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 7.