These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

85 related articles for article (PubMed ID: 259650)

  • 1. Effect of rubber closures on the stability of stannous ion in reagent kits for radiopharmaceuticals.
    Petry NA; Shaw SM; Kessler WV; Born GS; Belcastro PF
    J Parenter Drug Assoc; 1979; 33(5):283-6. PubMed ID: 259650
    [No Abstract]   [Full Text] [Related]  

  • 2. Deterioration of stannous ion in radiopharmaceutical kits during storage.
    McBride MH; Shaw SM; Kessler WV
    Am J Hosp Pharm; 1979 Oct; 36(10):1370-2. PubMed ID: 507080
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Technical problems associated with the production of technetium Tc 99m tin(II) pyrophosphate kits.
    Kowalsky RJ; Dalton DR
    Am J Hosp Pharm; 1981 Nov; 38(11):1722-6. PubMed ID: 7304626
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Structural identification of extractables from rubber closures used for pre-filled semisolid drug applicator by chromatography, mass spectrometry, and organic synthesis.
    Zhang F; Chang A; Karaisz K; Feng R; Cai J
    J Pharm Biomed Anal; 2004 Mar; 34(5):841-9. PubMed ID: 15019018
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Re: Stability of stannous ion in stannous pyrophosphate kits.
    Kowalsky RJ; Chilton HM
    J Nucl Med; 1983 Nov; 24(11):1080-1. PubMed ID: 6631529
    [No Abstract]   [Full Text] [Related]  

  • 6. Stannous ion quantitation in 99mTc-radiopharmaceutical kits.
    Chervu LR; Vallabhajosyula B; Mani J; Chun SB; Blaufox MD
    Eur J Nucl Med; 1982; 7(7):291-3. PubMed ID: 6288381
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Determination of Sn(II) in technetium cold kits by voltammetry at the hanging mercury drop electrode (HMDE) and relevant radiopharmaceutical applications.
    Decristoforo C; Obendorf D; Reichart E; Stubauer G; Riccabona G
    Nucl Med Biol; 1998 Oct; 25(7):675-83. PubMed ID: 9804049
    [TBL] [Abstract][Full Text] [Related]  

  • 8. The impact of primary packaging on the quality of parenteral products.
    Solomun L; Ibric S; Boltic Z; Djuric Z; Stupar B
    J Pharm Biomed Anal; 2008 Nov; 48(3):744-8. PubMed ID: 18786797
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Effect of heat on the physical properties of rubber closures.
    Hopkins GH
    Bull Parenter Drug Assoc; 1968; 22(4):181-6. PubMed ID: 5743231
    [No Abstract]   [Full Text] [Related]  

  • 10. Colorimetric determination of tin(II) levels in 99mTc labelling kits.
    Vyth A
    Pharm Weekbl Sci; 1982 Jun; 4(3):79-82. PubMed ID: 7110910
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Interaction of rubber closures with powders for parenteral administration.
    Jaehnke RW; Kreuter J; Ross G
    J Parenter Sci Technol; 1990; 44(5):282-8. PubMed ID: 2250205
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Natural rubber pharmaceutical vial closures release latex allergens that produce skin reactions.
    Primeau MN; Adkinson NF; Hamilton RG
    J Allergy Clin Immunol; 2001 Jun; 107(6):958-62. PubMed ID: 11398071
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Stabilization of stannous pyrophosphate kits with gentisic acid.
    Ballinger JR; Pygas J; Gerson B; Gulenchyn KY
    Int J Rad Appl Instrum B; 1988; 15(4):391-3. PubMed ID: 3255734
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Selection of rubber closures for parenterals.
    Greene GE
    Bull Parenter Drug Assoc; 1973; 27(4):195-200. PubMed ID: 4726574
    [No Abstract]   [Full Text] [Related]  

  • 15. Control tests in the manufacture of rubber closures.
    Hopkins GH
    Bull Parenter Drug Assoc; 1968; 22(1):48-52. PubMed ID: 5636762
    [No Abstract]   [Full Text] [Related]  

  • 16. Effect of Sn(II) ion concentration and heparin on technetium-99m red blood cell labeling.
    Rao SA; Knobel J; Collier BD; Isitman AT
    J Nucl Med; 1986 Jul; 27(7):1202-6. PubMed ID: 3014088
    [TBL] [Abstract][Full Text] [Related]  

  • 17. A device for coring tendency determinations in rubber closures.
    Preston WA
    J Parenter Sci Technol; 1986; 40(5):207-11. PubMed ID: 3794899
    [No Abstract]   [Full Text] [Related]  

  • 18. Permeation of preservative through rubber membranes as a basis for predicting loss of preservative into rubber closures.
    Anderson NR; Motzi JJ
    J Parenter Sci Technol; 1982; 36(4):161-7. PubMed ID: 7131210
    [No Abstract]   [Full Text] [Related]  

  • 19. European test methods for rubber closures.
    Brinkhoff O
    Bull Parenter Drug Assoc; 1969; 23(3):114-8. PubMed ID: 5807464
    [No Abstract]   [Full Text] [Related]  

  • 20. Steam sterilization of rubber closures in sealed nylon bags.
    Butler LD; Haydu EJ; Chrai S
    J Parenter Sci Technol; 1982; 36(3):99-101. PubMed ID: 7097459
    [No Abstract]   [Full Text] [Related]  

    [Next]    [New Search]
    of 5.