BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

199 related articles for article (PubMed ID: 25969641)

  • 1. Can sonographic measurement of optic nerve sheath diameter be used to detect raised intracranial pressure in patients with tuberculous meningitis? A prospective observational study.
    Sangani SV; Parikh S
    Indian J Radiol Imaging; 2015; 25(2):173-6. PubMed ID: 25969641
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Evaluation of Bedside Sonographic Measurement of Optic Nerve Sheath Diameter for Assessment of Raised Intracranial Pressure in Adult Head Trauma Patients.
    Mathews A; Cattamanchi S; Panneerselvam T; Trichur RV
    J Emerg Trauma Shock; 2020; 13(3):190-195. PubMed ID: 33304068
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Comparison of Optic Nerve Sheath Diameters Measured by Optic Ultrasonography Before and After Lumbar Puncture in Idiopathic Intracranial Hypertension Patients.
    Bozdoğan Z; Şenel E; Özmuk Ö; Karataş H; Kurşun O
    Noro Psikiyatr Ars; 2023; 60(2):117-123. PubMed ID: 37287564
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Elevated intracranial pressure detected by bedside emergency ultrasonography of the optic nerve sheath.
    Blaivas M; Theodoro D; Sierzenski PR
    Acad Emerg Med; 2003 Apr; 10(4):376-81. PubMed ID: 12670853
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Comparison of ultrasonography and computed tomography for measuring optic nerve sheath diameter for the detection of elevated intracranial pressure.
    Kim DY; Kim SY; Hong DY; Sung BY; Lee S; Paik JH; Jung HM
    Clin Neurol Neurosurg; 2021 May; 204():106609. PubMed ID: 33813371
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Measurement of optic nerve sheath diameter by ultrasound: a means of detecting acute raised intracranial pressure in hydrocephalus.
    Newman WD; Hollman AS; Dutton GN; Carachi R
    Br J Ophthalmol; 2002 Oct; 86(10):1109-13. PubMed ID: 12234888
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Emergency department sonographic measurement of optic nerve sheath diameter to detect findings of increased intracranial pressure in adult head injury patients.
    Tayal VS; Neulander M; Norton HJ; Foster T; Saunders T; Blaivas M
    Ann Emerg Med; 2007 Apr; 49(4):508-14. PubMed ID: 16997419
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Measurement of changes in optic nerve sheath diameter using ultrasound and computed tomography scan before and after the ventriculoperitoneal shunt surgery in patients with hydrocephalus - A prospective observational trial.
    Bhandari D; Udupi Bidkar P; Adinarayanan S; Narmadhalakshmi K; Srinivasan S
    Br J Neurosurg; 2019 Apr; 33(2):125-130. PubMed ID: 30880478
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Optic Nerve Sheath Ultrasound for the Detection and Monitoring of Raised Intracranial Pressure in Tuberculous Meningitis.
    Donovan J; Oanh PKN; Dobbs N; Phu NH; Nghia HDT; Summers D; Thuong NTT; Thwaites GE;
    Clin Infect Dis; 2021 Nov; 73(9):e3536-e3544. PubMed ID: 33283229
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Correlation of measurement of optic nerve sheath diameter using ultrasound with magnetic resonance imaging.
    Shirodkar CG; Munta K; Rao SM; Mahesh MU
    Indian J Crit Care Med; 2015 Aug; 19(8):466-70. PubMed ID: 26321806
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Optic nerve sheath diameter measurement: a means of detecting raised ICP in adult traumatic and non-traumatic neurosurgical patients.
    Raffiz M; Abdullah JM
    Am J Emerg Med; 2017 Jan; 35(1):150-153. PubMed ID: 27852525
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Optic nerve sonographic examination to predict raised intracranial pressure in idiopathic intracranial hypertension: The cut-off points.
    Kishk NA; Ebraheim AM; Ashour AS; Badr NM; Eshra MA
    Neuroradiol J; 2018 Oct; 31(5):490-495. PubMed ID: 30024291
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Sonographic assessment of optic nerve and ophthalmic vessels in patients with idiopathic intracranial hypertension.
    Ebraheim AM; Mourad HS; Kishk NA; Badr Eldin N; Saad AA
    Neurol Res; 2018 Sep; 40(9):728-735. PubMed ID: 29799769
    [TBL] [Abstract][Full Text] [Related]  

  • 14. The role of optic nerve sheath diameter ultrasound in brain infection.
    Stead GA; Cresswell FV; Jjunju S; Oanh PKN; Thwaites GE; Donovan J
    eNeurologicalSci; 2021 Jun; 23():100330. PubMed ID: 33728383
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Bedside sonographic measurement of optic nerve sheath diameter as a predictor of intracranial pressure in ED.
    Komut E; Kozacı N; Sönmez BM; Yılmaz F; Komut S; Yıldırım ZN; Beydilli İ; Yel C
    Am J Emerg Med; 2016 Jun; 34(6):963-7. PubMed ID: 26944107
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Optic Nerve Sheath Diameter: Correlation With Intra-Ventricular Intracranial Measurements in Predicting Dysfunctional Intracranial Compliance.
    Sahu S; Panda N; Swain A; Mathew P; Singla N; Gupta S; Jangra K; Bhardwaj A; Bhagat H
    Cureus; 2021 Jan; 13(1):e13008. PubMed ID: 33659139
    [TBL] [Abstract][Full Text] [Related]  

  • 17. The subarachnoid space surrounding the optic nerves. An ultrasound study of the optic nerve sheath.
    Hansen HC; Helmke K
    Surg Radiol Anat; 1996; 18(4):323-8. PubMed ID: 8983112
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Real-time optic nerve sheath diameter reduction measured with bedside ultrasound after therapeutic lumbar puncture in a patient with idiopathic intracranial hypertension.
    Singleton J; Dagan A; Edlow JA; Hoffmann B
    Am J Emerg Med; 2015 Jun; 33(6):860.e5-7. PubMed ID: 25595270
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Optic Nerve Sheath Diameter: A Cross-Sectional Study of Ultrasonographic Measurement in Healthy Black South African Adults.
    Trollip L; Alberto K; Makgotloe A
    Life (Basel); 2023 Sep; 13(10):. PubMed ID: 37895361
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Optic nerve sheath diameter as a marker for evaluation and prognostication of intracranial pressure in Indian patients: An observational study.
    Shirodkar CG; Rao SM; Mutkule DP; Harde YR; Venkategowda PM; Mahesh MU
    Indian J Crit Care Med; 2014 Nov; 18(11):728-34. PubMed ID: 25425840
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.