117 related articles for article (PubMed ID: 2597468)
41. Evaluation of Björk-Shiley prosthetic valves by real-time two-dimensional Doppler echocardiographic flow mapping. Dittrich H; Nicod P; Hoit B; Dalton N; Sahn D Am Heart J; 1988 Jan; 115(1 Pt 1):133-8. PubMed ID: 3336968 [TBL] [Abstract][Full Text] [Related]
42. Results of a comparative in vitro study of Duromedics and Björk-Shiley monostrut mitral heart valve prostheses. Heiliger R; Geks J; Mittermayer C J Biomed Eng; 1987 Apr; 9(2):128-33. PubMed ID: 3573751 [TBL] [Abstract][Full Text] [Related]
43. Evaluation of mechanical loading of a trileaflet polyurethane blood pump valve by finite element analysis. Knierbein B; Mohr-Matuschek U; Rechlin M; Reul H; Rau G; Michaeli W Int J Artif Organs; 1990 May; 13(5):307-15. PubMed ID: 2365486 [TBL] [Abstract][Full Text] [Related]
44. Evaluation of polyurethane sac type blood pump after 232 and 288 days total artificial heart (TAH) pumping without anticoagulant. Imachi K; Fujimasa I; Miyake H; Takido N; Nakajima M; Kouno A; Ono T; Mori Y; Nagaoka S; Kawase S; Kikuchi T; Atsumi K Trans Am Soc Artif Intern Organs; 1981; 27():118-22. PubMed ID: 7331064 [No Abstract] [Full Text] [Related]
45. The Björk-Shiley and Ionescu-Shiley heart valve prostheses. In vitro comparison of their hydrodynamic performance in the mitral position. Scotten LN; Walker DK; Brownlee RT Scand J Thorac Cardiovasc Surg; 1983; 17(3):201-9. PubMed ID: 6648395 [TBL] [Abstract][Full Text] [Related]
46. The five-year evaluation of a mechanical heart valve without anticoagulation in goats. Björk VO; Kaminsky DB J Thorac Cardiovasc Surg; 1992 Jul; 104(1):22-5. PubMed ID: 1614211 [TBL] [Abstract][Full Text] [Related]
47. Hydrodynamic function of a biostable polyurethane flexible heart valve after six months in sheep. Wheatley DJ; Bernacca GM; Tolland MM; O'Connor B; Fisher J; Williams DF Int J Artif Organs; 2001 Feb; 24(2):95-101. PubMed ID: 11256515 [TBL] [Abstract][Full Text] [Related]
48. Mean velocity and Reynolds stress measurements in the regurgitant jets of tilting disk heart valves in an artificial heart environment. Maymir JC; Deutsch S; Meyer RS; Geselowitz DB; Tarbell JM Ann Biomed Eng; 1998; 26(1):146-56. PubMed ID: 10355559 [TBL] [Abstract][Full Text] [Related]
49. Variability of regurgitation in Björk-Shiley mitral valves and relationship to disc occluder design: an in vitro two-dimensional color-Doppler flow mapping study. Lindower PD; Dellsperger KC; Johnson B; Chandran KB; Vandenberg BF J Heart Valve Dis; 1996 Aug; 5 Suppl 2():S178-83. PubMed ID: 8905518 [TBL] [Abstract][Full Text] [Related]
50. A tricuspid polyurethane heart valve as an alternative to mechanical prostheses or bioprostheses. Lo HB; Herold M; Reul H; Mückter H; Taguchi K; Surmann M; Hildinger KH; Lambertz H; de Haan H; Handt S ASAIO Trans; 1988; 34(3):839-44. PubMed ID: 3196608 [TBL] [Abstract][Full Text] [Related]
51. Material and design factors in thromboembolization in total artificial heart recipients living 100-2,000 hours. Unger F; Olsen DB; Oster H; Kolff WJ Eur Surg Res; 1976; 8(2):105-16. PubMed ID: 954777 [TBL] [Abstract][Full Text] [Related]
53. In vitro velocity and turbulence measurements in the vicinity of three new mechanical aortic heart valve prostheses: Björk-Shiley Monostrut, Omni-Carbon, and Duromedics. Yoganathan AP; Sung HW; Woo YR; Jones M J Thorac Cardiovasc Surg; 1988 May; 95(5):929-39. PubMed ID: 3361941 [TBL] [Abstract][Full Text] [Related]
54. In-vitro localization of initial flow-induced thrombus formation in bileaflet mechanical heart valves. Scharfschwerdt M; Thomschke M; Sievers HH ASAIO J; 2009; 55(1):19-23. PubMed ID: 19092660 [TBL] [Abstract][Full Text] [Related]
55. A paracorporeal pump with new valves for atrio-aortic left heart assist. Rennekamp F; Clevert HD; Hennig E; Bücherl ES Trans Am Soc Artif Intern Organs; 1979; 25():249-53. PubMed ID: 524589 [No Abstract] [Full Text] [Related]
56. Residence time distributions in artificial ventricles. Shettigar UR; Dropmann M; Christian PE; Kolff WJ ASAIO Trans; 1989; 35(3):708-12. PubMed ID: 2597571 [TBL] [Abstract][Full Text] [Related]
57. Development of an artificial heart valve. Björk VO Ann Thorac Surg; 1990 Jul; 50(1):151-4. PubMed ID: 2196016 [TBL] [Abstract][Full Text] [Related]
58. Numerical simulation of steady flow in a two-dimensional total artificial heart model. Kim SH; Chandran KB; Chen CJ J Biomech Eng; 1992 Nov; 114(4):497-503. PubMed ID: 1487902 [TBL] [Abstract][Full Text] [Related]
59. [Comparative study of mechanical heart valves for implantation in mitral position]. Heiliger R; Lambertz H; Geks J; Mittermayer C Herz; 1987 Dec; 12(6):405-12. PubMed ID: 3428845 [TBL] [Abstract][Full Text] [Related]
60. Development and evaluation of a swine model to assess the preclinical safety of mechanical heart valves. Grehan JF; Hilbert SL; Ferrans VJ; Droel JS; Salerno CT; Bianco RW J Heart Valve Dis; 2000 Sep; 9(5):710-9; discussion 719-20. PubMed ID: 11041189 [TBL] [Abstract][Full Text] [Related] [Previous] [Next] [New Search]