203 related articles for article (PubMed ID: 25975450)
1. Practical calibration curve of small-type optically stimulated luminescence (OSL) dosimeter for evaluation of entrance skin dose in the diagnostic X-ray region.
Takegami K; Hayashi H; Okino H; Kimoto N; Maehata I; Kanazawa Y; Okazaki T; Kobayashi I
Radiol Phys Technol; 2015 Jul; 8(2):286-94. PubMed ID: 25975450
[TBL] [Abstract][Full Text] [Related]
2. Energy dependence measurement of small-type optically stimulated luminescence (OSL) dosimeter by means of characteristic X-rays induced with general diagnostic X-ray equipment.
Takegami K; Hayashi H; Okino H; Kimoto N; Maehata I; Kanazawa Y; Okazaki T; Hashizume T; Kobayashi I
Radiol Phys Technol; 2016 Jan; 9(1):99-108. PubMed ID: 26589210
[TBL] [Abstract][Full Text] [Related]
3. Entrance surface dose measurements using a small OSL dosimeter with a computed tomography scanner having 320 rows of detectors.
Takegami K; Hayashi H; Yamada K; Mihara Y; Kimoto N; Kanazawa Y; Higashino K; Yamashita K; Hayashi F; Okazaki T; Hashizume T; Kobayashi I
Radiol Phys Technol; 2017 Mar; 10(1):49-59. PubMed ID: 27341805
[TBL] [Abstract][Full Text] [Related]
4. Estimation of identification limit for a small-type OSL dosimeter on the medical images by measurement of X-ray spectra.
Takegami K; Hayashi H; Okino H; Kimoto N; Maehata I; Kanazawa Y; Okazaki T; Hashizume T; Kobayashi I
Radiol Phys Technol; 2016 Jul; 9(2):286-92. PubMed ID: 27260346
[TBL] [Abstract][Full Text] [Related]
5. An optically stimulated luminescence dosimeter for measuring patient exposure from imaging guidance procedures.
Ding GX; Malcolm AW
Phys Med Biol; 2013 Sep; 58(17):5885-97. PubMed ID: 23920245
[TBL] [Abstract][Full Text] [Related]
6. Determination of multislice computed tomography dose index (CTDI) using optically stimulated luminescence technology.
Ruan C; Yukihara EG; Clouse WJ; Gasparian PB; Ahmad S
Med Phys; 2010 Jul; 37(7):3560-8. PubMed ID: 20831063
[TBL] [Abstract][Full Text] [Related]
7. Characterization of the nanoDot OSLD dosimeter in CT.
Scarboro SB; Cody D; Alvarez P; Followill D; Court L; Stingo FC; Zhang D; McNitt-Gray M; Kry SF
Med Phys; 2015 Apr; 42(4):1797-807. PubMed ID: 25832070
[TBL] [Abstract][Full Text] [Related]
8. Characterization of a commercially-available, optically-stimulated luminescent dosimetry system for use in computed tomography.
Lavoie L; Ghita M; Brateman L; Arreola M
Health Phys; 2011 Sep; 101(3):299-310. PubMed ID: 21799346
[TBL] [Abstract][Full Text] [Related]
9. A disposable OSL dosimeter for in vivo measurement of rectum dose during brachytherapy.
Hayashi H; Kimoto N; Maeda T; Tomita E; Asahara T; Goto S; Kanazawa Y; Shitakubo Y; Sakuragawa K; Ikushima H; Okazaki T; Hashizume T
Med Phys; 2021 Aug; 48(8):4621-4635. PubMed ID: 33760234
[TBL] [Abstract][Full Text] [Related]
10. [Fabrication of annealing equipment for optically stimulated luminescence (OSL) dosimeter].
Nakagawa K; Hayashi H; Okino H; Takegami K; Okazaki T; Kobayashi I
Nihon Hoshasen Gijutsu Gakkai Zasshi; 2014 Oct; 70(10):1135-42. PubMed ID: 25327423
[TBL] [Abstract][Full Text] [Related]
11. Entrance Skin Dose (ESD) and Bucky Table Induced Backscattered Dose (BTI-BSD) in Abdominal Radiography With nanoDot Optically Stimulated Luminescence Dosimeter (OSLD).
Sayed IS; Roslan NS; Syed WS
Cureus; 2023 Feb; 15(2):e34585. PubMed ID: 36891018
[TBL] [Abstract][Full Text] [Related]
12. Calibration and time fading characterization of a new optically stimulated luminescence film dosimeter.
Caprioli M; Delombaerde L; De Saint-Hubert M; de Freitas Nascimento L; De Roover R; Himschoot K; van der Heyden B; Vandenbroucke D; Leblans P; Crijns W
Med Phys; 2023 Feb; 50(2):1185-1193. PubMed ID: 36353946
[TBL] [Abstract][Full Text] [Related]
13. Investigation of backscatter factor in medical radiography using anthropomorphic phantom by optically stimulated luminescence dosimeter.
Arimoto A; Asada Y
Biomed Phys Eng Express; 2021 Sep; 7(6):. PubMed ID: 34438389
[TBL] [Abstract][Full Text] [Related]
14. Characteristics of an OSLD in the diagnostic energy range.
Al-Senan RM; Hatab MR
Med Phys; 2011 Jul; 38(7):4396-405. PubMed ID: 21859040
[TBL] [Abstract][Full Text] [Related]
15. An optically stimulated luminescence system to measure dose profiles in x-ray computed tomography.
Yukihara EG; Ruan C; Gasparian PB; Clouse WJ; Kalavagunta C; Ahmad S
Phys Med Biol; 2009 Oct; 54(20):6337-52. PubMed ID: 19809126
[TBL] [Abstract][Full Text] [Related]
16. Simulation evaluation of NIST air-kerma rate calibration standard for electronic brachytherapy.
Hiatt JR; Rivard MJ; Hughes HG
Med Phys; 2016 Mar; 43(3):1119-29. PubMed ID: 26936699
[TBL] [Abstract][Full Text] [Related]
17. In vivo dosimetry with optically stimulated luminescent dosimeters, OSLDs, compared to diodes; the effects of buildup cap thickness and fabrication material.
Jursinic PA; Yahnke CJ
Med Phys; 2011 Oct; 38(10):5432-40. PubMed ID: 21992362
[TBL] [Abstract][Full Text] [Related]
18. Commissioning optically stimulated luminescence in vivo dosimeters for fast neutron therapy.
Young LA; Yang F; Woodworth D; McCormick Z; Sandison G
Med Phys; 2016 Jan; 43(1):314. PubMed ID: 26745925
[TBL] [Abstract][Full Text] [Related]
19. Use of Commercially Available Optically Stimulated Luminescence Dosimeter As Extremity Dose Estimator.
Georgeson DL; Christiansen BH
Health Phys; 2021 Jan; 120(1):86-93. PubMed ID: 32384374
[TBL] [Abstract][Full Text] [Related]
20. Performance of optically stimulated luminescence Al₂O₃ dosimeter for low doses of diagnostic energy X-rays.
Lim CS; Lee SB; Jin GH
Appl Radiat Isot; 2011 Oct; 69(10):1486-9. PubMed ID: 21723134
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]