BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

227 related articles for article (PubMed ID: 25977115)

  • 21. Evaluation of monoenergetic late iodine enhancement dual-energy computed tomography for imaging of chronic myocardial infarction.
    Wichmann JL; Arbaciauskaite R; Kerl JM; Frellesen C; Bodelle B; Lehnert T; Monsefi N; Vogl TJ; Bauer RW
    Eur Radiol; 2014 Jun; 24(6):1211-8. PubMed ID: 24599623
    [TBL] [Abstract][Full Text] [Related]  

  • 22. Detection of Myocardial Infarction Using Delayed Enhancement Dual-Energy CT in Stable Patients.
    Rodriguez-Granillo GA; Campisi R; Deviggiano A; de Munain MNL; Zan M; Capunay C; Carrascosa P
    AJR Am J Roentgenol; 2017 Nov; 209(5):1023-1032. PubMed ID: 28858542
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Ion range estimation by using dual energy computed tomography.
    Hünemohr N; Krauss B; Dinkel J; Gillmann C; Ackermann B; Jäkel O; Greilich S
    Z Med Phys; 2013 Dec; 23(4):300-13. PubMed ID: 23597413
    [TBL] [Abstract][Full Text] [Related]  

  • 24. Dual-energy, standard and low-kVp contrast-enhanced CT-cholangiography: a comparative analysis of image quality and radiation exposure.
    Stiller W; Schwarzwaelder CB; Sommer CM; Veloza S; Radeleff BA; Kauczor HU
    Eur J Radiol; 2012 Jul; 81(7):1405-12. PubMed ID: 21458939
    [TBL] [Abstract][Full Text] [Related]  

  • 25. Dual-contrast agent photon-counting computed tomography of the heart: initial experience.
    Symons R; Cork TE; Lakshmanan MN; Evers R; Davies-Venn C; Rice KA; Thomas ML; Liu CY; Kappler S; Ulzheimer S; Sandfort V; Bluemke DA; Pourmorteza A
    Int J Cardiovasc Imaging; 2017 Aug; 33(8):1253-1261. PubMed ID: 28289990
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Myocardial Extracellular Volume Fraction with Dual-Energy Equilibrium Contrast-enhanced Cardiac CT in Nonischemic Cardiomyopathy: A Prospective Comparison with Cardiac MR Imaging.
    Lee HJ; Im DJ; Youn JC; Chang S; Suh YJ; Hong YJ; Kim YJ; Hur J; Choi BW
    Radiology; 2016 Jul; 280(1):49-57. PubMed ID: 27322972
    [TBL] [Abstract][Full Text] [Related]  

  • 27. Split-Bolus Portal Venous Phase Dual-Energy CT Urography: Protocol Design, Image Quality, and Dose Reduction.
    Chen CY; Hsu JS; Jaw TS; Shih MC; Lee LJ; Tsai TH; Liu GC
    AJR Am J Roentgenol; 2015 Nov; 205(5):W492-501. PubMed ID: 26496571
    [TBL] [Abstract][Full Text] [Related]  

  • 28. Computed tomography (CT) venography with dual-energy CT: low tube voltage and dose reduction of contrast medium for detection of deep vein thrombosis.
    Ichikawa S; Ichikawa T; Motosugi U; Imaizumi A; Sano K; Morisaka H
    J Comput Assist Tomogr; 2014; 38(5):797-801. PubMed ID: 24887576
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Virtual single-source computed tomography using dual-source acquisition: a new technique for the dose-neutral intraindividual comparison of different scan protocols.
    Werncke T; Meyer BC; Wacker FK; von Falck C
    Invest Radiol; 2014 Nov; 49(11):742-8. PubMed ID: 24918463
    [TBL] [Abstract][Full Text] [Related]  

  • 30. The feasibility of colorectal cancer detection using dual-energy computed tomography with iodine mapping.
    Boellaard TN; Henneman OD; Streekstra GJ; Venema HW; Nio CY; van Dorth-Rombouts MC; Stoker J
    Clin Radiol; 2013 Aug; 68(8):799-806. PubMed ID: 23615035
    [TBL] [Abstract][Full Text] [Related]  

  • 31. Tin-filter enhanced dual-energy-CT: image quality and accuracy of CT numbers in virtual noncontrast imaging.
    Kaufmann S; Sauter A; Spira D; Gatidis S; Ketelsen D; Heuschmid M; Claussen CD; Thomas C
    Acad Radiol; 2013 May; 20(5):596-603. PubMed ID: 23490736
    [TBL] [Abstract][Full Text] [Related]  

  • 32. Sixty-four-MSCT in the characterization of porcine acute and subacute myocardial infarction: determination of transmurality in comparison to magnetic resonance imaging and histopathology.
    Brodoefel H; Klumpp B; Reimann A; Fenchel M; Heuschmid M; Miller S; Schroeder S; Claussen C; Scheule AM; Kopp AF
    Eur J Radiol; 2007 May; 62(2):235-46. PubMed ID: 17187952
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Prospectively ECG-triggered rapid kV-switching dual-energy CT for quantitative imaging of myocardial perfusion.
    So A; Hsieh J; Imai Y; Narayanan S; Kramer J; Procknow K; Dutta S; Leipsic J; Min JK; Labounty T; Lee TY
    JACC Cardiovasc Imaging; 2012 Aug; 5(8):829-36. PubMed ID: 22897997
    [TBL] [Abstract][Full Text] [Related]  

  • 34. Evaluation of hyperdense renal lesions incidentally detected on single-phase post-contrast CT using dual-energy CT.
    Cha D; Kim CK; Park JJ; Park BK
    Br J Radiol; 2016 Jun; 89(1062):20150860. PubMed ID: 27043480
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Feasibility of discriminating uric acid from non-uric acid renal stones using consecutive spatially registered low- and high-energy scans obtained on a conventional CT scanner.
    Leng S; Shiung M; Ai S; Qu M; Vrtiska TJ; Grant KL; Krauss B; Schmidt B; Lieske JC; McCollough CH
    AJR Am J Roentgenol; 2015 Jan; 204(1):92-7. PubMed ID: 25539242
    [TBL] [Abstract][Full Text] [Related]  

  • 36. Evaluation of dual energy computed tomography iodine mapping within the myocardial blood pool for detection of acute myocardial infarction: correlation with histopathological findings in a porcine model.
    Sun K; Han R; Zhao R; Bai S; Wang J; Hu J; Lu B
    Br J Radiol; 2018 Jul; 91(1087):20170569. PubMed ID: 29688745
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Dual energy computed tomography for the head.
    Naruto N; Itoh T; Noguchi K
    Jpn J Radiol; 2018 Feb; 36(2):69-80. PubMed ID: 29119457
    [TBL] [Abstract][Full Text] [Related]  

  • 38. Dual-energy CT iodine maps as an alternative quantitative imaging biomarker to abdominal CT perfusion: determination of appropriate trigger delays for acquisition using bolus tracking.
    Skornitzke S; Fritz F; Mayer P; Koell M; Hansen J; Pahn G; Hackert T; Kauczor HU; Stiller W
    Br J Radiol; 2018 May; 91(1085):20170351. PubMed ID: 29446319
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Pearls, Pitfalls, and Problems in Dual-Energy Computed Tomography Imaging of the Body.
    Wortman JR; Sodickson AD
    Radiol Clin North Am; 2018 Jul; 56(4):625-640. PubMed ID: 29936951
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Low tube voltage improves computed tomography imaging of delayed myocardial contrast enhancement in an experimental acute myocardial infarction model.
    Mahnken AH; Bruners P; Mühlenbruch G; Emmerich M; Hohl C; Günther RW; Wildberger JE
    Invest Radiol; 2007 Feb; 42(2):123-9. PubMed ID: 17220730
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 12.