These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

504 related articles for article (PubMed ID: 25978864)

  • 1. How to enhance the stability of locking plate fixation of proximal humerus fractures? An overview of current biomechanical and clinical data.
    Schliemann B; Wähnert D; Theisen C; Herbort M; Kösters C; Raschke MJ; Weimann A
    Injury; 2015 Jul; 46(7):1207-14. PubMed ID: 25978864
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Biomechanical in vitro assessment of screw augmentation in locked plating of proximal humerus fractures.
    Röderer G; Scola A; Schmölz W; Gebhard F; Windolf M; Hofmann-Fliri L
    Injury; 2013 Oct; 44(10):1327-32. PubMed ID: 23769470
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Augmentation of plate osteosynthesis for proximal humeral fractures: a systematic review of current biomechanical and clinical studies.
    Biermann N; Prall WC; Böcker W; Mayr HO; Haasters F
    Arch Orthop Trauma Surg; 2019 Aug; 139(8):1075-1099. PubMed ID: 30903343
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Biomechanical effect of medial cortical support and medial screw support on locking plate fixation in proximal humeral fractures with a medial gap: a finite element analysis.
    Yang P; Zhang Y; Liu J; Xiao J; Ma LM; Zhu CR
    Acta Orthop Traumatol Turc; 2015; 49(2):203-9. PubMed ID: 26012943
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Screw augmentation reduces motion at the bone-implant interface: a biomechanical study of locking plate fixation of proximal humeral fractures.
    Schliemann B; Seifert R; Rosslenbroich SB; Theisen C; Wähnert D; Raschke MJ; Weimann A
    J Shoulder Elbow Surg; 2015 Dec; 24(12):1968-73. PubMed ID: 26255200
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Reducing Postoperative Fracture Displacement After Locked Plating of Proximal Humerus Fractures: Current Concepts.
    Newman JM; Kahn M; Gruson KI
    Am J Orthop (Belle Mead NJ); 2015 Jul; 44(7):312-20. PubMed ID: 26161759
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Internal fixation of proximal humerus fractures using the locking proximal humerus plate.
    Plecko M; Kraus A
    Oper Orthop Traumatol; 2005 Feb; 17(1):25-50. PubMed ID: 16007377
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Technical tips: dualplate fixation technique for comminuted proximal humerus fractures.
    Choi S; Kang H; Bang H
    Injury; 2014 Aug; 45(8):1280-2. PubMed ID: 24813097
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Current concepts in locking plate fixation of proximal humerus fractures.
    Laux CJ; Grubhofer F; Werner CML; Simmen HP; Osterhoff G
    J Orthop Surg Res; 2017 Sep; 12(1):137. PubMed ID: 28946902
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Biomechanical effects of calcar screws and bone block augmentation on medial support in locked plating of proximal humeral fractures.
    Katthagen JC; Schwarze M; Meyer-Kobbe J; Voigt C; Hurschler C; Lill H
    Clin Biomech (Bristol); 2014 Aug; 29(7):735-41. PubMed ID: 24997810
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Biomechanical effect of the configuration of screw hole style on locking plate fixation in proximal humerus fracture with a simulated gap: A finite element analysis.
    Zhang YK; Wei HW; Lin KP; Chen WC; Tsai CL; Lin KJ
    Injury; 2016 Jun; 47(6):1191-5. PubMed ID: 26975793
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Calcar screw position in proximal humerus fracture fixation: Don't miss high!
    Mehta S; Chin M; Sanville J; Namdari S; Hast MW
    Injury; 2018 Mar; 49(3):624-629. PubMed ID: 29452734
    [TBL] [Abstract][Full Text] [Related]  

  • 13. A novel surgical approach and technique and short-term clinical efficacy for the treatment of proximal humerus fractures with the combined use of medial anatomical locking plate fixation and minimally invasive lateral locking plate fixation.
    Wang F; Wang Y; Dong J; He Y; Li L; Liu F; Dong J
    J Orthop Surg Res; 2021 Jan; 16(1):29. PubMed ID: 33422119
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Biomechanical behavior of three types of fixation in the two-part proximal humerus fracture without medial cortical support.
    di Tullio PO; Giordano V; Souto E; Assed H; Chequer JP; Belangero W; Mariolani JRL; Koch HA
    PLoS One; 2019; 14(7):e0220523. PubMed ID: 31361778
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Operative treatment of 2-part surgical neck fractures of the proximal humerus (AO 11-A3) in the elderly: Cement augmented locking plate Philos™ vs. proximal humerus nail MultiLoc®.
    Helfen T; Siebenbürger G; Mayer M; Böcker W; Ockert B; Haasters F
    BMC Musculoskelet Disord; 2016 Oct; 17(1):448. PubMed ID: 27793135
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Biomechanical comparison of a unique locking plate versus a standard plate for internal fixation of proximal humerus fractures in a cadaveric model.
    Walsh S; Reindl R; Harvey E; Berry G; Beckman L; Steffen T
    Clin Biomech (Bristol); 2006 Dec; 21(10):1027-31. PubMed ID: 16919375
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Screws with larger core diameter and lower thread pitch increase the stability of locked plating in osteoporotic proximal humeral fractures.
    Schliemann B; Risse N; Frank A; Müller M; Michel P; Raschke MJ; Katthagen JC
    Clin Biomech (Bristol); 2019 Mar; 63():21-26. PubMed ID: 30784787
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Which additional augmented fixation procedure decreases surgical failure after proximal humeral fracture with medial comminution: fibular allograft or inferomedial screws?
    Kim DS; Lee DH; Chun YM; Shin SJ
    J Shoulder Elbow Surg; 2018 Oct; 27(10):1852-1858. PubMed ID: 29735375
    [TBL] [Abstract][Full Text] [Related]  

  • 19. The importance of medial support in locked plating of proximal humerus fractures.
    Gardner MJ; Weil Y; Barker JU; Kelly BT; Helfet DL; Lorich DG
    J Orthop Trauma; 2007 Mar; 21(3):185-91. PubMed ID: 17473755
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Locking plate and fibular allograft augmentation in unstable fractures of proximal humerus.
    Matassi F; Angeloni R; Carulli C; Civinini R; Di Bella L; Redl B; Innocenti M
    Injury; 2012 Nov; 43(11):1939-42. PubMed ID: 22921382
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 26.