BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

141 related articles for article (PubMed ID: 2598418)

  • 1. Assessment of left-to-right atrial shunting after percutaneous mitral valvuloplasty by transesophageal color Doppler flow-mapping.
    Yoshida K; Yoshikawa J; Akasaka T; Yamaura Y; Shakudo M; Hozumi T; Fukaya T
    Circulation; 1989 Dec; 80(6):1521-6. PubMed ID: 2598418
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Quantification of left-to-right atrial shunting and defect size after balloon mitral commissurotomy using biplane transesophageal echocardiography, color flow Doppler mapping, and the principle of proximal flow convergence.
    Rittoo D; Sutherland GR; Shaw TR
    Circulation; 1993 May; 87(5):1591-603. PubMed ID: 8491015
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Transesophageal color Doppler flow mapping of iatrogenic left-to-right interatrial shunting after percutaneous transluminal mitral valvotomy.
    Chen CH; Lin SL; Yin WH; Liou JY; Hsu TL; Ting CT; Chang MS; Chiang BN
    Echocardiography; 1991 Nov; 8(6):649-56. PubMed ID: 10149276
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Residual atrial septal defects following balloon mitral valvuloplasty using different techniques. A transthoracic and transoesophageal echocardiography study demonstrating an advantage of the Inoue balloon.
    Thomas MR; Monaghan MJ; Metcalfe JM; Jewitt DE
    Eur Heart J; 1992 Apr; 13(4):496-502. PubMed ID: 1600988
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Atrial septal defect after percutaneous mitral balloon valvuloplasty: immediate results and follow-up.
    Casale P; Block PC; O'Shea JP; Palacios IF
    J Am Coll Cardiol; 1990 May; 15(6):1300-4. PubMed ID: 2329236
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Role of transesophageal echocardiography in pre- and post-percutaneous balloon mitral valvuloplasty.
    Li SP; Yang HY; Liu HY; Dai RP
    Chin Med J (Engl); 1994 Dec; 107(12):897-902. PubMed ID: 7882726
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Atrial septal defect after balloon mitral valvuloplasty: a transesophageal echocardiographic study.
    Arora R; Jolly N; Kalra GS; Khalilullah M
    Angiology; 1993 Mar; 44(3):217-21. PubMed ID: 8442531
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Value and limitations of color Doppler echocardiography in the evaluation of percutaneous balloon mitral valvuloplasty for isolated mitral stenosis.
    Parro A; Helmcke F; Mahan EF; Nanda NC; Kandath D; Dean LS
    Am J Cardiol; 1991 Jun; 67(15):1261-7. PubMed ID: 2035452
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Methodologic issues in clinical evaluation of stenosis severity in adults undergoing aortic or mitral balloon valvuloplasty. The NHLBI Balloon Valvuloplasty Registry.
    Otto CM; Davis KB; Holmes DR; O'Neill W; Ferguson J; Bashore TM; Bonan R
    Am J Cardiol; 1992 Jun; 69(19):1607-16. PubMed ID: 1598878
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Echocardiographic and hemodynamic characteristics of atrial septal defects created by percutaneous valvuloplasty.
    Kronzon I; Tunick PA; Goldfarb A; Freedberg RS; Chinitz L; Slater J; Schwinger ME; Gindea AJ; Glassman E; Daniel WG
    J Am Soc Echocardiogr; 1990; 3(1):64-71. PubMed ID: 2310594
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Mitral valve area calculations immediately after percutaneous balloon mitral valvuloplasty: effect of the atrial septal defect.
    Manga P; Singh S; Brandis S; Friedman B
    J Am Coll Cardiol; 1993 Jun; 21(7):1568-73. PubMed ID: 8496521
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Elevated left atrial pressure does not cause left-to-right shunting after mitral balloon valvuloplasty.
    Watson KR; Chisholm RJ; Azpiri JR; Armstrong PW
    Cathet Cardiovasc Diagn; 1991 Nov; 24(3):173-5. PubMed ID: 1764735
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Pulmonary venous flow dynamics before and after balloon mitral valvuloplasty as determined by transesophageal Doppler echocardiography.
    Jolly N; Arora R; Mohan JC; Khalilullah M
    Am J Cardiol; 1992 Sep; 70(7):780-4. PubMed ID: 1519530
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Use of Amplatzer septal occluder in a case of residual atrial septal defect causing bidirectional shunting after percutaneous Inoue mitral balloon valvuloplasty.
    Zanchetta M; Onorato E; Rigatelli G; Dimopoulos K; Pedon L; Zennaro M; Maiolino P
    J Invasive Cardiol; 2001 Mar; 13(3):223-6. PubMed ID: 11231648
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Spontaneous left atrial echo contrast, mitral annular systolic velocity, and left atrial appendage late emptying velocity in predicting improvement of left atrial function after percutaneous balloon mitral valvuloplasty.
    Arava TN; Durgaprasad R; Velam V; Gajjala OR; Neelam VK; Manohar SN
    Echocardiography; 2018 Feb; 35(2):162-169. PubMed ID: 29178504
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Incidence and predictors of atrial septal defect after percutaneous transvenous mitral commissurotomy - a transesophageal echocardiographic study of 209 cases.
    Manjunath CN; Panneerselvam A; Srinivasa KH; Prabhavathi B; Rangan K; Dhanalakshmi C; Ravindranath KS
    Echocardiography; 2013 Feb; 30(2):127-30. PubMed ID: 23231417
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Transesophageal Doppler color flow mapping assessment of atrial septal defect.
    Mehta RH; Helmcke F; Nanda NC; Hsiung M; Pacifico AD; Hsu TL
    J Am Coll Cardiol; 1990 Oct; 16(4):1010-6. PubMed ID: 2212350
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Transesophageal echocardiography to detect atrial clots in candidates for percutaneous transseptal mitral balloon valvuloplasty.
    Kronzon I; Tunick PA; Glassman E; Slater J; Schwinger M; Freedberg RS
    J Am Coll Cardiol; 1990 Nov; 16(5):1320-2. PubMed ID: 2229782
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Long-term follow-up of iatrogenic atrial septal defect: after percutaneous mitral balloon valvuloplasty.
    Korkmaz S; Demirkan B; Guray Y; Yilmaz MB; Sasmaz H
    Tex Heart Inst J; 2011; 38(5):523-7. PubMed ID: 22163126
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Transesophageal echocardiography during percutaneous balloon mitral valvuloplasty.
    Jaarsma W; Visser CA; Suttorp MJ; Haagen FD; Ernst SM
    J Am Soc Echocardiogr; 1990; 3(5):384-91. PubMed ID: 2245031
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 8.