These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

50 related articles for article (PubMed ID: 2598688)

  • 21. Dental implants.
    Holt R
    J West Soc Periodontol Periodontal Abstr; 1986; 34(2):49-55. PubMed ID: 2943904
    [No Abstract]   [Full Text] [Related]  

  • 22. Activation of human leukocytes on tantalum trabecular metal in comparison to commonly used orthopedic metal implant materials.
    Schildhauer TA; Peter E; Muhr G; Köller M
    J Biomed Mater Res A; 2009 Feb; 88(2):332-41. PubMed ID: 18286637
    [TBL] [Abstract][Full Text] [Related]  

  • 23. Metal-ceramic alloys in dentistry: a review.
    Roberts HW; Berzins DW; Moore BK; Charlton DG
    J Prosthodont; 2009 Feb; 18(2):188-94. PubMed ID: 19178620
    [TBL] [Abstract][Full Text] [Related]  

  • 24. [Experimental evaluation of metallic bone implants in the rat].
    Passi P; Miotti A; Musajo F; Gobbato S; Danieli D
    G Stomatol Ortognatodonzia; 1985; 3(1):99-103. PubMed ID: 3858261
    [No Abstract]   [Full Text] [Related]  

  • 25. [The electrochemical behavior of titanium and dental casting in modelling oral conditions].
    Pelsoczi-Kovács I; Kutsán G; Rauscher A; Fazekas A
    Fogorv Sz; 2005 Dec; 98(6):251-5. PubMed ID: 16468487
    [TBL] [Abstract][Full Text] [Related]  

  • 26. Effect of surface reaction layer on grindability of cast titanium alloys.
    Ohkubo C; Hosoi T; Ford JP; Watanabe I
    Dent Mater; 2006 Mar; 22(3):268-74. PubMed ID: 16083955
    [TBL] [Abstract][Full Text] [Related]  

  • 27. The effect of mucine, IgA, urea, and lysozyme on the corrosion behavior of various non-precious dental alloys and pure titanium in artificial saliva.
    Bilhan H; Bilgin T; Cakir AF; Yuksel B; Von Fraunhofer JA
    J Biomater Appl; 2007 Nov; 22(3):197-221. PubMed ID: 17255155
    [TBL] [Abstract][Full Text] [Related]  

  • 28. [Possibilities for improvement of the surface properties of dental implants (2). The use of ceramic oxides in surface coating for titanium and tantalum implants].
    Szabó G; Kovács L; Vargha K
    Fogorv Sz; 1995 Feb; 88(2):73-7. PubMed ID: 7875341
    [TBL] [Abstract][Full Text] [Related]  

  • 29. Static immersion and irritation tests of dental metal-ceramic alloys.
    Ardlin BI; Dahl JE; Tibballs JE
    Eur J Oral Sci; 2005 Feb; 113(1):83-9. PubMed ID: 15693834
    [TBL] [Abstract][Full Text] [Related]  

  • 30. [Estimation of the corrosion potential of certain metals and alloys used as implants].
    Charron LF
    Rev Odontoimplantol; 1974; 6(51):10-5. PubMed ID: 4527351
    [No Abstract]   [Full Text] [Related]  

  • 31. Corrosion resistance of the implant materials Contimet 35, Memory, and Vitallium in artificial physiological fluids.
    Geis-Gerstorfer J; Weber H
    Int J Oral Maxillofac Implants; 1988; 3(2):135-40. PubMed ID: 3251822
    [No Abstract]   [Full Text] [Related]  

  • 32. Titanium modified with layer-by-layer sol-gel tantalum oxide and an organodiphosphonic acid: a coating for hydroxyapatite growth.
    Arnould C; Volcke C; Lamarque C; Thiry PA; Delhalle J; Mekhalif Z
    J Colloid Interface Sci; 2009 Aug; 336(2):497-503. PubMed ID: 19481760
    [TBL] [Abstract][Full Text] [Related]  

  • 33. Systemic metal ion levels in dental implant patients.
    Smith DC; Lugowski S; McHugh A; Deporter D; Watson PA; Chipman M
    Int J Oral Maxillofac Implants; 1997; 12(6):828-34. PubMed ID: 9425764
    [TBL] [Abstract][Full Text] [Related]  

  • 34. A study of the abrasive resistance of metal alloys with applications in dental prosthetic fixators.
    Gil FJ; Fernández E; Manero JM; Planell JA; Sabrià J; Cortada M; Giner L
    Biomed Mater Eng; 1995; 5(3):161-7. PubMed ID: 8555966
    [TBL] [Abstract][Full Text] [Related]  

  • 35. Machinability of cast commercial titanium alloys.
    Watanabe I; Kiyosue S; Ohkubo C; Aoki T; Okabe T
    J Biomed Mater Res; 2002; 63(6):760-4. PubMed ID: 12418021
    [TBL] [Abstract][Full Text] [Related]  

  • 36. [Artifacts induced by dental reconstruction materials: the case of titanium].
    Savane S; N'Dindin AC; N'Dindin GB; Kouame PA; Doyon D
    Odontostomatol Trop; 2001 Sep; 24(95):33-7. PubMed ID: 11808373
    [TBL] [Abstract][Full Text] [Related]  

  • 37. Effect of metal primers on bond strength of resin cements to base metals.
    Fonseca RG; de Almeida JG; Haneda IG; Adabo GL
    J Prosthet Dent; 2009 Apr; 101(4):262-8. PubMed ID: 19328279
    [TBL] [Abstract][Full Text] [Related]  

  • 38. The castability of pure titanium compared with Ni-Cr and Ni-Cr-Be alloys.
    Paulino SM; Leal MB; Pagnano VO; Bezzon OL
    J Prosthet Dent; 2007 Dec; 98(6):445-54. PubMed ID: 18061738
    [TBL] [Abstract][Full Text] [Related]  

  • 39. Titanium for prosthodontic applications: a review of the literature.
    Wang RR; Fenton A
    Quintessence Int; 1996 Jun; 27(6):401-8. PubMed ID: 8941834
    [TBL] [Abstract][Full Text] [Related]  

  • 40. Bending resistance of prefabricated titanium posts following molten cast core attachment.
    Pfeiffer P; Nergiz I; Schmage P; Platzer U
    Oper Dent; 2004; 29(4):404-9. PubMed ID: 15279479
    [TBL] [Abstract][Full Text] [Related]  

    [Previous]   [Next]    [New Search]
    of 3.