BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

200 related articles for article (PubMed ID: 25990093)

  • 1. Utility of cardiac computed tomography for evaluation of pannus in mechanical aortic valve.
    Suh YJ; Kim YJ; Lee S; Hong YJ; Lee HJ; Hur J; Choi BW; Chang BC
    Int J Cardiovasc Imaging; 2015 Aug; 31(6):1271-80. PubMed ID: 25990093
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Impact of pannus formation on hemodynamic dysfunction of prosthetic aortic valve: pannus extent and its relationship to prosthetic valve motion and degree of stenosis.
    Koo HJ; Ha H; Kang JW; Kim JA; Song JK; Kim HJ; Lim TH; Yang DH
    Clin Res Cardiol; 2018 Jul; 107(7):554-564. PubMed ID: 29460005
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Added value of cardiac computed tomography for evaluation of mechanical aortic valve: Emphasis on evaluation of pannus with surgical findings as standard reference.
    Suh YJ; Lee S; Im DJ; Chang S; Hong YJ; Lee HJ; Hur J; Choi BW; Chang BC; Shim CY; Hong GR; Kim YJ
    Int J Cardiol; 2016 Jul; 214():454-60. PubMed ID: 27096962
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Reoperation for non-structural valvular dysfunction caused by pannus ingrowth in aortic valve prosthesis.
    Oh SJ; Park S; Kim JS; Kim KH; Kim KB; Ahn H
    J Heart Valve Dis; 2013 Jul; 22(4):591-8. PubMed ID: 24224426
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Subprosthetic Pannus after Aortic Valve Replacement Surgery: Cardiac CT Findings and Clinical Features.
    Han K; Yang DH; Shin SY; Kim N; Kang JW; Kim DH; Song JM; Kang DH; Song JK; Kim JB; Jung SH; Choo SJ; Chung CH; Lee JW; Lim TH
    Radiology; 2015 Sep; 276(3):724-31. PubMed ID: 25902187
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Assessment of mitral annuloplasty ring by cardiac computed tomography: Correlation with echocardiographic parameters and comparison between two different ring types.
    Suh YJ; Chang BC; Im DJ; Kim YJ; Hong YJ; Hong GR; Kim YJ
    J Thorac Cardiovasc Surg; 2015 Nov; 150(5):1082-90. PubMed ID: 26277476
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Comparison of Aortic Annulus Dimension After Aortic Valve Neocuspidization With Valve Replacement and Normal Valve.
    Yamamoto Y; Iino K; Shintani Y; Kato H; Kimura K; Watanabe G; Takemura H
    Semin Thorac Cardiovasc Surg; 2017 Summer; 29(2):143-149. PubMed ID: 28823320
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Sixty-Four-Section Cardiac Computed Tomography in Mechanical Prosthetic Heart Valve Dysfunction: Thrombus or Pannus.
    Gündüz S; Özkan M; Kalçik M; Gürsoy OM; Astarcioğlu MA; Karakoyun S; Aykan AÇ; Biteker M; Gökdeniz T; Kaya H; Yesin M; Duran NE; Sevinç D; Güneysu T
    Circ Cardiovasc Imaging; 2015 Dec; 8(12):. PubMed ID: 26659372
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Multidetector CT predictors of prosthesis-patient mismatch in transcatheter aortic valve replacement.
    Freeman M; Webb JG; Willson AB; Wheeler M; Blanke P; Moss RR; Thompson CR; Munt B; Norgaard BL; Yang TH; Min JK; Poulsen S; Hansson NC; Binder RK; Toggweiler S; Hague C; Wood DA; Pibarot P; Leipsic J
    J Cardiovasc Comput Tomogr; 2013; 7(4):248-55. PubMed ID: 24148778
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Long-term hemodynamic performance of ATS valves in the aortic position: impact on the progression of late tricuspid regurgitation.
    Jeong DS; Kim WS; Sung K; Yang JH; Jun TG; Lee YT; Park PW
    J Heart Valve Dis; 2013 Nov; 22(6):794-803. PubMed ID: 24597400
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Ten-year comparison of pericardial tissue valves versus mechanical prostheses for aortic valve replacement in patients younger than 60 years of age.
    Weber A; Noureddine H; Englberger L; Dick F; Gahl B; Aymard T; Czerny M; Tevaearai H; Stalder M; Carrel TP
    J Thorac Cardiovasc Surg; 2012 Nov; 144(5):1075-83. PubMed ID: 22341653
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Factors affecting computed tomography image quality for assessment of mechanical aortic valves.
    Suh YJ; Kim YJ; Hong YJ; Lee HJ; Hur J; Hong SR; Im DJ; Kim YJ; Choi BW
    Int J Cardiovasc Imaging; 2016 Jun; 32 Suppl 1():63-71. PubMed ID: 26626457
    [TBL] [Abstract][Full Text] [Related]  

  • 13. National trends in utilization and in-hospital outcomes of mechanical versus bioprosthetic aortic valve replacements.
    Isaacs AJ; Shuhaiber J; Salemi A; Isom OW; Sedrakyan A
    J Thorac Cardiovasc Surg; 2015 May; 149(5):1262-9.e3. PubMed ID: 25791947
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Is early antithrombotic therapy necessary in patients with bioprosthetic aortic valves in normal sinus rhythm?
    ElBardissi AW; DiBardino DJ; Chen FY; Yamashita MH; Cohn LH
    J Thorac Cardiovasc Surg; 2010 May; 139(5):1137-45. PubMed ID: 20303508
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Prosthesis-patient mismatch in bovine pericardial aortic valves: evaluation using 3 different modalities and associated medium-term outcomes.
    Chacko SJ; Ansari AH; McCarthy PM; Malaisrie SC; Andrei AC; Li Z; Lee R; McGee E; Bonow RO; Puthumana JJ
    Circ Cardiovasc Imaging; 2013 Sep; 6(5):776-83. PubMed ID: 23926194
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Fifteen years of clinical and echocardiographic follow up with the carbomedics heart valve.
    Carrier M; Pellerin M; Basmadjian A; Bouchard D; Perrault LP; Cartier R; Pagé P; Demers P; Hébert Y
    J Heart Valve Dis; 2006 Jan; 15(1):67-72; discussion 72. PubMed ID: 16480014
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Serial changes of hemodynamic performance with Medtronic Hall valve in aortic position.
    Cho YH; Jeong DS; Park PW; Park KH; Sung K; Kim WS; Lee YT
    Ann Thorac Surg; 2011 Feb; 91(2):424-31. PubMed ID: 21256283
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Surgical sutureless and transcatheter aortic valves: hemodynamic performance and clinical outcomes in propensity score-matched high-risk populations with severe aortic stenosis.
    Kamperidis V; van Rosendael PJ; de Weger A; Katsanos S; Regeer M; van der Kley F; Mertens B; Sianos G; Ajmone Marsan N; Bax JJ; Delgado V
    JACC Cardiovasc Interv; 2015 Apr; 8(5):670-7. PubMed ID: 25946438
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Prosthesis-Specific Predictors of Paravalvular Regurgitation after Transcatheter Aortic Valve Replacement: Impact of Calcification and Sizing on Balloon-Expandable versus Self-Expandable Transcatheter Heart Valves.
    Stähli BE; Nguyen-Kim TD; Gebhard C; Erhart L; Frauenfelder T; Tanner FC; Falk V; Landmesser U; Nietlispach F; Lüscher TF; Maier W; Binder RK
    J Heart Valve Dis; 2015 Jan; 24(1):10-21. PubMed ID: 26182615
    [TBL] [Abstract][Full Text] [Related]  

  • 20. The CarboMedics supra-annular Top Hat valve improves long-term left ventricular mass regression.
    Mosquera VX; Bouzas-Mosquera A; Bautista-Hernandez V; Estévez-Cid F; Herrera-Noreña JM; Alvarez-García N; Cuenca-Castillo JJ
    J Thorac Cardiovasc Surg; 2014 Dec; 148(6):2845-53.e1. PubMed ID: 25131169
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.