274 related articles for article (PubMed ID: 26000596)
1. Measurement of intraocular pressure in healthy unanesthetized inland bearded dragons (Pogona vitticeps).
Schuster EJ; Strueve J; Fehr MJ; Mathes KA
Am J Vet Res; 2015 Jun; 76(6):494-9. PubMed ID: 26000596
[TBL] [Abstract][Full Text] [Related]
2. Ophthalmic examination, biometry, and histologic findings in captive inland bearded dragons (Pogona vitticeps).
Martin de Bustamante MG; Johnson AN; Shippy SG; Allgood H; Plummer CE
Vet Ophthalmol; 2020 Jul; 23(4):696-706. PubMed ID: 32459050
[TBL] [Abstract][Full Text] [Related]
3. Evaluation of a rebound tonometer (Tonovet) in clinically normal cat eyes.
Rusanen E; Florin M; Hässig M; Spiess BM
Vet Ophthalmol; 2010 Jan; 13(1):31-6. PubMed ID: 20149173
[TBL] [Abstract][Full Text] [Related]
4. Comparison of intraocular pressure measurements using rebound (TonoVet
McDonald JE; Knollinger AM; Dustin Dees D; MacLaren NE
Vet Ophthalmol; 2017 Mar; 20(2):155-159. PubMed ID: 27111099
[TBL] [Abstract][Full Text] [Related]
5. Evaluation of intraocular pressure in conscious ferrets (Mustela putorius furo) by means of rebound tonometry and comparison with applanation tonometry.
Di Girolamo N; Andreani V; Guandalini A; Selleri P
Vet Rec; 2013 Apr; 172(15):396. PubMed ID: 23486504
[TBL] [Abstract][Full Text] [Related]
6. Evaluation of intraocular pressure in conscious Hermann's tortoises (Testudo hermanni) by means of rebound tonometry.
Selleri P; Di Girolamo N; Andreani V; Guandalini A; D'Anna N
Am J Vet Res; 2012 Nov; 73(11):1807-12. PubMed ID: 23106468
[TBL] [Abstract][Full Text] [Related]
7. Evaluation of intraocular pressure measurements obtained by use of a rebound tonometer and applanation tonometer in dogs before and after elective phacoemulsification.
Thompson-Hom AL; Gerding PA
Am J Vet Res; 2012 May; 73(5):709-13. PubMed ID: 22533404
[TBL] [Abstract][Full Text] [Related]
8. COMPARISON OF INTRAOCULAR PRESSURE MEASUREMENT USING REBOUND AND APPLANATION TONOMETRY IN LOGGERHEAD (
Lamagna B; Affuso A; Micieli F; Mennonna G; Meomartino L; Valle GD; Ciampa M; Treglia G; Hochscheid S
J Zoo Wildl Med; 2021 Jun; 52(2):604-609. PubMed ID: 34130403
[TBL] [Abstract][Full Text] [Related]
9. Twenty-four-hour measurement of IOP in rabbits using rebound tonometer.
Wang X; Dong J; Wu Q
Vet Ophthalmol; 2013 Nov; 16(6):423-8. PubMed ID: 23279703
[TBL] [Abstract][Full Text] [Related]
10. Evaluation of a rebound tonometer for measuring intraocular pressure in dogs and horses.
Knollinger AM; La Croix NC; Barrett PM; Miller PE
J Am Vet Med Assoc; 2005 Jul; 227(2):244-8. PubMed ID: 16047660
[TBL] [Abstract][Full Text] [Related]
11. Influence of topical anesthesia on tonometric values of intraocular pressure.
Baudouin C; Gastaud P
Ophthalmologica; 1994; 208(6):309-13. PubMed ID: 7845645
[TBL] [Abstract][Full Text] [Related]
12. Twenty-four-Hour Measurement of Intraocular Pressure in Guinea Pigs (Cavia porcellus).
Ansari-Mood M; Mehdi-Rajaei S; Sadjadi R; Selk-Ghaffari M; Williams DL
J Am Assoc Lab Anim Sci; 2016 Jan; 55(1):95-7. PubMed ID: 26817986
[TBL] [Abstract][Full Text] [Related]
13. Evaluation of intraocular pressure in eyes of clinically normal llamas and alpacas.
Willis AM; Anderson DE; Gemensky AJ; Wilkie DA; Silveira F
Am J Vet Res; 2000 Dec; 61(12):1542-4. PubMed ID: 11131596
[TBL] [Abstract][Full Text] [Related]
14. In vitro and in vivo comparison of applanation tonometry and rebound tonometry in dogs.
Nagata N; Yuki M; Hasegawa T
J Vet Med Sci; 2011 Dec; 73(12):1585-9. PubMed ID: 21804316
[TBL] [Abstract][Full Text] [Related]
15. Intraocular pressure reference intervals in eyes of clinically normal miniature donkeys (Equus africanus asinus).
Hibbs CD; Barrett PM; Dees DD
Vet Ophthalmol; 2019 Jan; 22(1):24-30. PubMed ID: 29517162
[TBL] [Abstract][Full Text] [Related]
16. Intraocular pressure in American Bullfrogs (Rana catesbeiana) measured with rebound and applanation tonometry.
Cannizzo SA; Lewbart GA; Westermeyer HD
Vet Ophthalmol; 2017 Nov; 20(6):526-532. PubMed ID: 28247466
[TBL] [Abstract][Full Text] [Related]
17. MEASURING INTRAOCULAR PRESSURE IN WHITE'S TREE FROGS (LITORIA CAERULEA) BY REBOUND TONOMETRY: COMPARING DEVICE, TIME OF DAY, AND MANUAL VERSUS CHEMICAL RESTRAINT METHODS.
Hausmann JC; Krisp A; Sladky K; Miller PE; Mans C
J Zoo Wildl Med; 2017 Jun; 48(2):413-419. PubMed ID: 28749263
[TBL] [Abstract][Full Text] [Related]
18. [Intraocular pressure measurement during the day and night for glaucoma patients and normal controls using Goldmann and Perkins applanation tonometry].
Wozniak K; Köller AU; Spörl E; Böhm AG; Pillunat LE
Ophthalmologe; 2006 Dec; 103(12):1027-31. PubMed ID: 17048019
[TBL] [Abstract][Full Text] [Related]
19. The effect of repeated measurements and the use of topical anesthetic on rebound tonometry values in children.
Dosunmu EO; Marcus I; Tung I; Thiamthat W; Freedman SF
J AAPOS; 2014 Dec; 18(6):619-21. PubMed ID: 25448141
[TBL] [Abstract][Full Text] [Related]
20. Comparison of invasive and non-invasive tonometry in the mouse.
Morris CA; Crowston JG; Lindsey JD; Danias J; Weinreb RN
Exp Eye Res; 2006 Jun; 82(6):1094-9. PubMed ID: 16466714
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]