237 related articles for article (PubMed ID: 26006786)
1. All-polyethylene tibial components are not inferior to metal-backed tibial components in long-term follow-up of knee arthroplasties.
Yassin M; Garti A; Weissbrot M; Ashkenazi U; Khatib M; Robinson D
Eur J Orthop Surg Traumatol; 2015 Aug; 25(6):1087-91. PubMed ID: 26006786
[TBL] [Abstract][Full Text] [Related]
2. All-polyethylene and metal-backed tibial components are equivalent with BMI of less than 37.5.
Toman J; Iorio R; Healy WL
Clin Orthop Relat Res; 2012 Jan; 470(1):108-16. PubMed ID: 21997784
[TBL] [Abstract][Full Text] [Related]
3. Modular Metal-Backed Tibial Components Provide Minimal Mid-Term Survivorship Benefits Despite Increased Cost and Frequency of Use: A Retrospective Review of the American Joint Replacement Registry Database.
Kelley B; Mullen K; De A; Sassoon A
J Arthroplasty; 2022 Aug; 37(8):1570-1574.e1. PubMed ID: 35189294
[TBL] [Abstract][Full Text] [Related]
4. All-polyethylene and metal-backed tibias have similar outcomes at 10 years: a randomized level I [corrected] evidence study.
Gioe TJ; Stroemer ES; Santos ER
Clin Orthop Relat Res; 2007 Feb; 455():212-8. PubMed ID: 17006363
[TBL] [Abstract][Full Text] [Related]
5. The rates of osteolysis and loosening associated with a modular posterior stabilized knee replacement. Results at five to fourteen years.
Lachiewicz PF; Soileau ES
J Bone Joint Surg Am; 2004 Mar; 86(3):525-30. PubMed ID: 14996878
[TBL] [Abstract][Full Text] [Related]
6. Metal or Modularity: Why Do Metal-Backed Tibias Have Inferior Outcomes to All-Polyethylene Tibial Components in Patients With Osteoarthritis.
Houdek MT; Watts CD; Wyles CC; Martin JR; Trousdale RT; Taunton MJ
J Arthroplasty; 2017 Mar; 32(3):836-842. PubMed ID: 27816367
[TBL] [Abstract][Full Text] [Related]
7. All-polyethylene versus metal-backed tibial component in total knee arthroplasty.
Longo UG; Ciuffreda M; D'Andrea V; Mannering N; Locher J; Denaro V
Knee Surg Sports Traumatol Arthrosc; 2017 Nov; 25(11):3620-3636. PubMed ID: 27209191
[TBL] [Abstract][Full Text] [Related]
8. All-Polyethylene Versus Metal-Backed Tibial Components-An Analysis of 27,733 Cruciate-Retaining Total Knee Replacements from the Swedish Knee Arthroplasty Register.
Gudnason A; Hailer NP; W-Dahl A; Sundberg M; Robertsson O
J Bone Joint Surg Am; 2014 Jun; 96(12):994-999. PubMed ID: 24951734
[TBL] [Abstract][Full Text] [Related]
9. A randomized comparison of all-polyethylene and metal-backed tibial components.
Gioe TJ; Bowman KR
Clin Orthop Relat Res; 2000 Nov; (380):108-15. PubMed ID: 11064980
[TBL] [Abstract][Full Text] [Related]
10. Long-term results of a total knee prosthesis utilising an all polyethylene tibial component.
Pai SK; Whitwell G; McMurray D; Stewart TD; Stone MH
Arch Orthop Trauma Surg; 2013 Aug; 133(8):1143-8. PubMed ID: 23748907
[TBL] [Abstract][Full Text] [Related]
11. A Meta-Analysis Comparing All-Polyethylene Tibial Component to Metal-Backed Tibial Component in Total Knee Arthroplasty: Assessing Survivorship and Functional Outcomes.
Voss B; El-Othmani MM; Schnur AK; Botchway A; Mihalko WM; Saleh KJ
J Arthroplasty; 2016 Nov; 31(11):2628-2636. PubMed ID: 27538714
[TBL] [Abstract][Full Text] [Related]
12. Comparative Survivorship of Different Tibial Designs in Primary Total Knee Arthroplasty.
Kremers HM; Sierra RJ; Schleck CD; Berry DJ; Cabanela ME; Hanssen AD; Pagnano MW; Trousdale RT; Lewallen DG
J Bone Joint Surg Am; 2014 Jul; 96(14):e121. PubMed ID: 25031383
[TBL] [Abstract][Full Text] [Related]
13. LCS mobile-bearing total knee replacement. A 10-year's follow-up study.
Vogt JC; Saarbach C
Orthop Traumatol Surg Res; 2009 May; 95(3):177-82. PubMed ID: 19328763
[TBL] [Abstract][Full Text] [Related]
14. Survivorship and clinical outcome of the minimally invasive Uniglide medial fixed bearing, all-polyethylene tibia, unicompartmental knee arthroplasty at a mean follow-up of 7.3years.
Forster-Horváth C; Artz N; Hassaballa MA; Robinson JR; Porteous AJ; Murray JR; Newman JH
Knee; 2016 Dec; 23(6):981-986. PubMed ID: 27506988
[TBL] [Abstract][Full Text] [Related]
15. All-polyethylene tibial components in octogenarians: survivorship, performance, and cost.
van der Ven A; Scott RD; Barnes CL
Am J Orthop (Belle Mead NJ); 2014 Jan; 43(1):21-4. PubMed ID: 24490181
[TBL] [Abstract][Full Text] [Related]
16. All-polyethylene tibial components in distal femur limb-salvage surgery: a finite element analysis based on promising clinical outcomes.
Tang F; Zhou Y; Zhang W; Min L; Shi R; Luo Y; Duan H; Tu C
J Orthop Surg Res; 2017 Apr; 12(1):57. PubMed ID: 28376828
[TBL] [Abstract][Full Text] [Related]
17. All-polyethylene versus metal-backed posterior stabilized total knee arthroplasty: similar 2-year results of a randomized radiostereometric analysis study.
Hasan S; Marang-Van De Mheen PJ; Kaptein BL; Nelissen RGHH; Toksvig-Larsen S
Acta Orthop; 2019 Dec; 90(6):590-595. PubMed ID: 31550947
[TBL] [Abstract][Full Text] [Related]
18. Economics of All-Polyethylene Versus Metal-Backed Tibial Prosthesis Designs.
Chambers MC; El-Othmani MM; Sayeed Z; Anoushiravani A; Schnur AK; Mihalko WM; Saleh KJ
Orthopedics; 2016 May; 39(3 Suppl):S61-6. PubMed ID: 27219732
[TBL] [Abstract][Full Text] [Related]
19. Fixation of high-flexion total knee prostheses: five-year follow-up results of a four-arm randomized controlled clinical and roentgen stereophotogrammetric analysis study.
Nieuwenhuijse MJ; van der Voort P; Kaptein BL; van der Linden-van der Zwaag HM; Valstar ER; Nelissen RG
J Bone Joint Surg Am; 2013 Oct; 95(19):e1411-11. PubMed ID: 24088976
[TBL] [Abstract][Full Text] [Related]
20. Randomized clinical trial of rotating-platform and fixed-bearing total knee arthroplasty: no clinically detectable differences at five years.
Kalisvaart MM; Pagnano MW; Trousdale RT; Stuart MJ; Hanssen AD
J Bone Joint Surg Am; 2012 Mar; 94(6):481-9. PubMed ID: 22437996
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]