These tools will no longer be maintained as of December 31, 2024. Archived website can be found here. PubMed4Hh GitHub repository can be found here. Contact NLM Customer Service if you have questions.


BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

104 related articles for article (PubMed ID: 26009903)

  • 1. Comparison of design and torque measurements of various manual wrenches.
    Neugebauer J; Petermöller S; Scheer M; Happe A; Faber FJ; Zoeller JE
    Int J Oral Maxillofac Implants; 2015; 30(3):526-33. PubMed ID: 26009903
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Accuracy of dental torque wrenches.
    Wood JS; Marlow NM; Cayouette MJ
    Gen Dent; 2015; 63(6):e20-2. PubMed ID: 26545283
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Variability of mechanical torque-limiting devices in clinical service at a US dental school.
    McCracken MS; Mitchell L; Hegde R; Mavalli MD
    J Prosthodont; 2010 Jan; 19(1):20-4. PubMed ID: 19765196
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Accuracy of the implant torque wrench following time in clinical service.
    Gutierrez J; Nicholls JI; Libman WJ; Butson TJ
    Int J Prosthodont; 1997; 10(6):562-7. PubMed ID: 9495178
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Loss of Accuracy of Torque Wrenches Due to Clinical Use and Cleaning Procedure: Short Communication.
    Stroosnijder E; Gresnigt MM; Meisberger EW; Cune MS
    Int J Prosthodont; 2016; 29(3):253-5. PubMed ID: 27148984
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Accuracy and precision of as-received implant torque wrenches.
    Britton-Vidal E; Baker P; Mettenburg D; Pannu DS; Looney SW; Londono J; Rueggeberg FA
    J Prosthet Dent; 2014 Oct; 112(4):811-6. PubMed ID: 25043286
    [TBL] [Abstract][Full Text] [Related]  

  • 7. The Accuracy of New and Aged Mechanical Torque Devices Employed in Five Dental Implant Systems.
    Erdem MA; Karatasli B; Dinçer Kose O; Kose TE; Çene E; Aydın Aya S; Cankaya AB
    Biomed Res Int; 2017; 2017():8652720. PubMed ID: 29238725
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Effects of infection control procedures on the accuracy of a new mechanical torque wrench system for implant restorations.
    Dellinges M; Curtis D
    J Prosthet Dent; 1996 Jan; 75(1):93-8. PubMed ID: 8850459
    [TBL] [Abstract][Full Text] [Related]  

  • 9. The Precision of Mechanical Torque Wrenches Used for Implants in Dental Offices.
    Steinebrunner L; Harder S; Wolfart S; Freitag-Wolf S; Kern M
    Int J Prosthodont; 2015; 28(5):527-30. PubMed ID: 26340015
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Comparison of torque measurements and clinical handling of various surgical motors.
    Neugebauer J; Scheer M; Mischkowski RA; An SH; Karapetian VE; Toutenburg H; Zoeller JE
    Int J Oral Maxillofac Implants; 2009; 24(3):469-76. PubMed ID: 19587869
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Accuracy of a manual torque application device for morse-taper implants: a technical note.
    Cehreli MC; Akça K; Tönük E
    Int J Oral Maxillofac Implants; 2004; 19(5):743-8. PubMed ID: 15508992
    [TBL] [Abstract][Full Text] [Related]  

  • 12. Experimental study on the factors affecting torque of beam-type implant torque wrenches.
    Shiba H; Sato Y; Furuya J; Osawa T; Isobe A; Hayashi M; Kitagawa N
    BMC Oral Health; 2021 Jul; 21(1):344. PubMed ID: 34266423
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Effect of activation rate on output torque values from a dental implant toggle-style torque wrench.
    Wadhwani CPK; Frantz WT; Schoenbaum TR; Rosen PS; Nhan D; Chung KH
    J Prosthet Dent; 2023 May; 129(5):763-768. PubMed ID: 34482966
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Accuracy and reliability of torque wrenches used for halo application in children.
    Copley LA; Dormans JP; Pepe MD; Tan V; Browne RH
    J Bone Joint Surg Am; 2003 Nov; 85(11):2199-204. PubMed ID: 14630853
    [TBL] [Abstract][Full Text] [Related]  

  • 15. Is there a need for standardization of tightening force used to connect the transducer for resonance frequency analysis in determining implant stability?
    Salatti DB; Pelegrine AA; Gehrke S; Teixeira ML; Moshaverinia A; Moy PK
    Int J Oral Maxillofac Implants; 2019; 34(4):886–890. PubMed ID: 30934030
    [TBL] [Abstract][Full Text] [Related]  

  • 16. Accuracy of mechanical torque devices for implants used in Brazilian dental offices.
    Santos GC; Passos SP; Coelho Santos MJ
    Int J Prosthodont; 2011; 24(1):38-9. PubMed ID: 21210000
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Effect of long-term steam autoclaving on changes in torque delivery of spring- and friction-type torque wrenches.
    Yilmaz B; L'Homme-Langlois E; Beck FM; McGlumphy E
    J Prosthet Dent; 2016 Jun; 115(6):718-21. PubMed ID: 26723095
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Accuracy of friction-style and spring-style mechanical torque limiting devices for dental implants.
    Vallee MC; Conrad HJ; Basu S; Seong WJ
    J Prosthet Dent; 2008 Aug; 100(2):86-92. PubMed ID: 18672124
    [TBL] [Abstract][Full Text] [Related]  

  • 19. Clinical outcome of dental implants placed with high insertion torques (up to 176 Ncm).
    Khayat PG; Arnal HM; Tourbah BI; Sennerby L
    Clin Implant Dent Relat Res; 2013 Apr; 15(2):227-33. PubMed ID: 21599832
    [TBL] [Abstract][Full Text] [Related]  

  • 20. Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
    Schmitt J; Holst S; Eitner S; Schlegel A; Wichmann M; Hamel J
    Int J Prosthodont; 2009; 22(2):193-200. PubMed ID: 19418868
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 6.