226 related articles for article (PubMed ID: 26015636)
1. Treatment of neglected femoral neck fractures using the modified dynamic hip screw with autogenous bone and bone morphogenetic protein-2 composite materials grafting.
Lin D; Zuo S; Li L; Wang L; Lian K
Indian J Orthop; 2015; 49(3):342-6. PubMed ID: 26015636
[TBL] [Abstract][Full Text] [Related]
2. Modified dynamic hip screw loaded with autologous bone graft for treating Pauwels type-3 vertical femoral neck fractures.
Luo D; Zou W; He Y; Xian H; Wang L; Shen J; Lian K; Lin D
Injury; 2017 Jul; 48(7):1579-1583. PubMed ID: 28583419
[TBL] [Abstract][Full Text] [Related]
3. [Osteosynthesis of intracapsular femoral neck fractures by dynamic hip screw (DHS) fixation].
Majernícek M; Dungl P; Kolman J; Malkus T; Vaculík J
Acta Chir Orthop Traumatol Cech; 2009 Aug; 76(4):319-25. PubMed ID: 19755057
[TBL] [Abstract][Full Text] [Related]
4. Hollow-bone-graft dynamic hip screw can fix and promote bone union after femoral neck fracture: an experimental research.
Shen JZ; Yao JF; Lin DS; Lian KJ; Ding ZQ; Lin B; Guo ZM; Zhang MH; Li Q; Li L; Qi P
Int J Med Sci; 2012; 9(10):916-22. PubMed ID: 23236261
[TBL] [Abstract][Full Text] [Related]
5. [Efficacy comparison between dynamic hip screw combined with anti-rotation screw and cannulated screw in treating femoral neck fractures].
Chen Z; Wang G; Lin J; Yang T; Fang Y; Liu L; Zhang H
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi; 2011 Jan; 25(1):26-9. PubMed ID: 21351604
[TBL] [Abstract][Full Text] [Related]
6. Dynamic hip screw and fibular strut graft for fixation of fresh femoral neck fracture with posterior comminution.
Elgeidi A; El Negery A; Abdellatif MS; El Moghazy N
Arch Orthop Trauma Surg; 2017 Oct; 137(10):1363-1369. PubMed ID: 28730395
[TBL] [Abstract][Full Text] [Related]
7. Augmented osteosynthesis with tensor fascia latae muscle pedicle bone grafting in neglected femoral neck fracture.
Bhuyan BK
Indian J Orthop; 2012 Jul; 46(4):439-46. PubMed ID: 22912520
[TBL] [Abstract][Full Text] [Related]
8. Neglected femoral neck fractures in adults.
Kainth GS; Yuvarajan P; Maini L; Kumar V
J Orthop Surg (Hong Kong); 2011 Apr; 19(1):13-7. PubMed ID: 21519069
[TBL] [Abstract][Full Text] [Related]
9. Unstable Intertrochanteric Fracture Fixation - Is Proximal Femoral Locked Compression Plate Better Than Dynamic Hip Screw.
Asif N; Ahmad S; Qureshi OA; Jilani LZ; Hamesh T; Jameel T
J Clin Diagn Res; 2016 Jan; 10(1):RC09-13. PubMed ID: 26894134
[TBL] [Abstract][Full Text] [Related]
10. Outcomes of dynamic hip screw augmented with trochanteric wiring for treatment of unstable type A2 intertrochanteric femur fractures.
Puram C; Pradhan C; Patil A; Sodhai V; Sancheti P; Shyam A
Injury; 2017 Aug; 48 Suppl 2():S72-S77. PubMed ID: 28802425
[TBL] [Abstract][Full Text] [Related]
11. Comparison of femoral neck system to multiple cancellous screws and dynamic hip screws in the treatment of femoral neck fractures.
Xu X; Fan J; Zhou F; Lv Y; Tian Y; Ji H; Zhang Z; Guo Y; Yang Z; Hou G
Injury; 2023 Apr; 54 Suppl 2():S28-S35. PubMed ID: 35367076
[TBL] [Abstract][Full Text] [Related]
12. Modified Pauwels' intertrochanteric osteotomy in neglected femoral neck fractures in children: a report of 10 cases followed for a minimum of 5 years.
Magu NK; Singh R; Sharma AK; Ummat V
J Orthop Trauma; 2007 Apr; 21(4):237-43. PubMed ID: 17414550
[TBL] [Abstract][Full Text] [Related]
13. Conversion to total hip arthroplasty after failed proximal femoral nail antirotations or dynamic hip screw fixations for stable intertrochanteric femur fractures: a retrospective study with a minimum follow-up of 3 years.
Zeng X; Zhan K; Zhang L; Zeng D; Yu W; Zhang X; Zhao M
BMC Musculoskelet Disord; 2017 Jan; 18(1):38. PubMed ID: 28122548
[TBL] [Abstract][Full Text] [Related]
14. Osteosynthesis of ununited femoral neck fracture by internal fixation combined with iliac crest bone chips and muscle pedicle bone grafting.
Baksi DD; Pal AK; Baksi DP
Indian J Orthop; 2016; 50(4):366-73. PubMed ID: 27512217
[TBL] [Abstract][Full Text] [Related]
15. Valgus osteotomy and repositioning and fixation with a dynamic hip screw and a 135º single-angled barrel plate for un-united and neglected femoral neck fractures.
Gupta S; Kukreja S; Singh V
J Orthop Surg (Hong Kong); 2014 Apr; 22(1):13-7. PubMed ID: 24781606
[TBL] [Abstract][Full Text] [Related]
16. Fixation with cancellous screws and fibular strut grafts for neglected femoral neck fractures.
Pal CP; Kumar B; Dinkar KS; Singh P; Kumar H; Goyal RK
J Orthop Surg (Hong Kong); 2014 Aug; 22(2):181-5. PubMed ID: 25163951
[TBL] [Abstract][Full Text] [Related]
17. A convenient way to do valgus osteotomy for neglected fracture neck of femur.
Bansal P; Singhal V; Lal H; Mittal D; Arya RK
Kathmandu Univ Med J (KUMJ); 2013; 11(42):147-51. PubMed ID: 24096223
[TBL] [Abstract][Full Text] [Related]
18. Proximal femoral locking plate with cannulated screws for the treatment of femoral neck fractures.
Lin D; Lian K; Ding Z; Zhai W; Hong J
Orthopedics; 2012 Jan; 35(1):e1-5. PubMed ID: 22229598
[TBL] [Abstract][Full Text] [Related]
19. [Comparison among three cannulated screws and dynamic hip screw combined with antirotation screw for comminut- ed fractures of femoral neck].
Hou WR; Xu MO
Zhongguo Gu Shang; 2015 Sep; 28(9):796-801. PubMed ID: 26647559
[TBL] [Abstract][Full Text] [Related]
20. Functional outcomes and perceived quality of life following fixation of femoral neck fractures in adults from 18 to 69 years using dynamic hip screw (DHS) and an additional anti-rotation screw- a retrospective analysis of 53 patients after a mean follow-up time of 4 years.
Fjeld A; Fülling T; Bula P; Bonnaire F
Eur J Trauma Emerg Surg; 2022 Jun; 48(3):1893-1903. PubMed ID: 35039893
[TBL] [Abstract][Full Text] [Related]
[Next] [New Search]