BIOMARKERS

Molecular Biopsy of Human Tumors

- a resource for Precision Medicine *

188 related articles for article (PubMed ID: 26026857)

  • 1. Removal of Polypropylene Sling Mesh From the Urethra: An Anatomic Technique.
    Freilich DA; Rovner ES
    Urology; 2015 Jul; 86(1):196-9. PubMed ID: 26026857
    [TBL] [Abstract][Full Text] [Related]  

  • 2. Transvaginal paravaginal repair of high-grade cystocele central and lateral defects with concomitant suburethral sling: report of early results, outcomes, and patient satisfaction with a new technique.
    Rodríguez LV; Bukkapatnam R; Shah SM; Raz S
    Urology; 2005 Nov; 66(5 Suppl):57-65. PubMed ID: 16194709
    [TBL] [Abstract][Full Text] [Related]  

  • 3. Removal of obstructing synthetic sling from a urethra: English and Spanish version.
    Pizarro-Berdichevsky J; Goldman MP; Goldman HB
    Int Urogynecol J; 2016 Dec; 27(12):1929-1931. PubMed ID: 27525688
    [TBL] [Abstract][Full Text] [Related]  

  • 4. Surgical management of lower urinary mesh perforation after mid-urethral polypropylene mesh sling: mesh excision, urinary tract reconstruction and concomitant pubovaginal sling with autologous rectus fascia.
    Shah K; Nikolavsky D; Gilsdorf D; Flynn BJ
    Int Urogynecol J; 2013 Dec; 24(12):2111-7. PubMed ID: 23824269
    [TBL] [Abstract][Full Text] [Related]  

  • 5. Spiral sling salvage anti-incontinence surgery in female patients with a nonfunctional urethra: technique and initial results.
    Rutman MP; Deng DY; Shah SM; Raz S; Rodríguez LV
    J Urol; 2006 May; 175(5):1794-8; discussion 1798-9. PubMed ID: 16600764
    [TBL] [Abstract][Full Text] [Related]  

  • 6. Transvaginal sling excision: tips and tricks.
    Clifton MM; Goldman HB
    Int Urogynecol J; 2017 Jan; 28(1):155-156. PubMed ID: 27530521
    [TBL] [Abstract][Full Text] [Related]  

  • 7. Complications of synthetic graft materials used in suburethral sling procedures.
    Tsui KP; Ng SC; Tee YT; Yeh GP; Chen GD
    Int Urogynecol J Pelvic Floor Dysfunct; 2005; 16(2):165-7. PubMed ID: 15789150
    [TBL] [Abstract][Full Text] [Related]  

  • 8. Management of urinary fistulas due to midurethral sling surgery.
    Blaivas JG; Mekel G
    J Urol; 2014 Oct; 192(4):1137-42. PubMed ID: 24742595
    [TBL] [Abstract][Full Text] [Related]  

  • 9. Urethral mesh erosion after single-incision mid-urethral sling.
    Minaglia S; Oyama IA
    Female Pelvic Med Reconstr Surg; 2012; 18(5):310-2. PubMed ID: 22983279
    [TBL] [Abstract][Full Text] [Related]  

  • 10. Management of vaginal erosion of polypropylene mesh slings.
    Kobashi KC; Govier FE
    J Urol; 2003 Jun; 169(6):2242-3. PubMed ID: 12771759
    [TBL] [Abstract][Full Text] [Related]  

  • 11. Transobturator approach to suburethral sling placement in the treatment of stress urinary incontinence in women.
    Shindel AW; Ruiz AC; Klutke CG
    Expert Rev Med Devices; 2005 Sep; 2(5):613-22. PubMed ID: 16293073
    [TBL] [Abstract][Full Text] [Related]  

  • 12. [Three years results of transvaginal cystocele repair with polypropylene mesh using a tension-free technique].
    El Harrech Y; Ameur A; Janane A; Moufide K; Ghadouane M; Abbar M
    Actas Urol Esp; 2010 Jan; 34(1):82-7. PubMed ID: 20223137
    [TBL] [Abstract][Full Text] [Related]  

  • 13. Polypropylene sling for treatment of stress urinary incontinence: an alternative to tension-free vaginal tape.
    Rodriguez LV; Berman J; Raz S
    Tech Urol; 2001 Jun; 7(2):87-9. PubMed ID: 11383999
    [TBL] [Abstract][Full Text] [Related]  

  • 14. Obturator foramen dissection for excision of symptomatic transobturator mesh.
    Reynolds WS; Kit LC; Kaufman MR; Karram M; Bales GT; Dmochowski RR
    J Urol; 2012 May; 187(5):1680-4. PubMed ID: 22425123
    [TBL] [Abstract][Full Text] [Related]  

  • 15. [Erosions of the vaginal, bladder and urethral mucosa after transvaginal correction of genital prolapse and stress urinary incontinence using synthetic materials].
    Nechiporenko AN; Nechiporenko NA
    Urologiia; 2013; (4):12-5. PubMed ID: 24159757
    [TBL] [Abstract][Full Text] [Related]  

  • 16. A novel technique of bulbourethral sling for post-prostatectomy incontinence.
    Wadie BS
    Scand J Urol Nephrol; 2007; 41(5):398-402. PubMed ID: 17853033
    [TBL] [Abstract][Full Text] [Related]  

  • 17. Removing a misplaced retropubic midurethral sling from the urethra and bladder neck using ear, nose, and throat instruments.
    Solomon ER; Jelovsek JE
    Obstet Gynecol; 2015 Jan; 125(1):58-61. PubMed ID: 25560104
    [TBL] [Abstract][Full Text] [Related]  

  • 18. Tension-free vaginal tape and percutaneous vaginal tape sling procedures.
    Rackley RR; Abdelmalak JB; Tchetgen MB; Madjar S; Jones S; Noble M
    Tech Urol; 2001 Jun; 7(2):90-100. PubMed ID: 11384000
    [TBL] [Abstract][Full Text] [Related]  

  • 19. A new technique combining both polypropylene and vaginal wall sling procedures: can it minimize the risk of urethral and vaginal erosion occurring with synthetic materials?
    Emir L; Erol D; Ak H; Sunay M
    World J Urol; 2005 Jul; 23(3):221-4. PubMed ID: 15997396
    [TBL] [Abstract][Full Text] [Related]  

  • 20. No incision and tension-free vaginal sling for stress urinary incontinence: The role of knotless barbed suture.
    Niu Q; Zheng J; Han X
    Med Hypotheses; 2018 Feb; 111():8-11. PubMed ID: 29407003
    [TBL] [Abstract][Full Text] [Related]  

    [Next]    [New Search]
    of 10.